ABAP Select data from SAP table TEMS_ANALYZED_EXPOS_UI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TEMS_ANALYZED_EXPOS_UI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TEMS_ANALYZED_EXPOS_UI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TEMS_ANALYZED_EXPOS_UI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TEMS_ANALYZED_EXPOS_UI TYPE STANDARD TABLE OF TEMS_ANALYZED_EXPOS_UI,
      WA_TEMS_ANALYZED_EXPOS_UI TYPE TEMS_ANALYZED_EXPOS_UI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TEMS_ANALYZED_EXPOS_UI> TYPE TEMS_ANALYZED_EXPOS_UI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TEMS_ANALYZED_EXPOS_UI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TEMS_ANALYZED_EXPOS_UI
  INTO TABLE IT_TEMS_ANALYZED_EXPOS_UI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TEMS_ANALYZED_EXPOS_UI
*  INTO TABLE @DATA(IT_TEMS_ANALYZED_EXPOS_UI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TEMS_ANALYZED_EXPOS_UI INDEX 1 INTO DATA(WA_TEMS_ANALYZED_EXPOS_UI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TEMS_ANALYZED_EXPOS_UI ASSIGNING <TEMS_ANALYZED_EXPOS_UI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TEMS_ANALYZED_EXPOS_UI>-EXPOSURE_ID = 1.
<TEMS_ANALYZED_EXPOS_UI>-EXPOSURE_ORIGIN = 1.
<TEMS_ANALYZED_EXPOS_UI>-LOG_SYSTEM = 1.
<TEMS_ANALYZED_EXPOS_UI>-PLANNING_PERIOD = 1.
<TEMS_ANALYZED_EXPOS_UI>-PLANNING_YEAR = 1.
ENDLOOP.

LOOP AT IT_TEMS_ANALYZED_EXPOS_UI INTO WA_TEMS_ANALYZED_EXPOS_UI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TEMS_ANALYZED_EXPOS_UI-DUE_DATE, sy-vline,
WA_TEMS_ANALYZED_EXPOS_UI-TRANSACTION_CAT, sy-vline,
WA_TEMS_ANALYZED_EXPOS_UI-SIGN, sy-vline,
WA_TEMS_ANALYZED_EXPOS_UI-COMPANY_CODE, sy-vline,
WA_TEMS_ANALYZED_EXPOS_UI-COUNTRY, sy-vline,
WA_TEMS_ANALYZED_EXPOS_UI-ATTRIBUTE_01, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TEMS_ANALYZED_EXPOS_UI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TEMS_ANALYZED_EXPOS_UI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TEMS_ANALYZED_EXPOS_UI INTO WA_TEMS_ANALYZED_EXPOS_UI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EXPOSURE_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TEMS_ANALYZED_EXPOS_UI-EXPOSURE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TEMS_ANALYZED_EXPOS_UI-EXPOSURE_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOG_SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TEMS_ANALYZED_EXPOS_UI-LOG_SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TEMS_ANALYZED_EXPOS_UI-LOG_SYSTEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field PLANNING_YEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_TEMS_ANALYZED_EXPOS_UI-PLANNING_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TEMS_ANALYZED_EXPOS_UI-PLANNING_YEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TOT_EXPOSURE_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TEMS_ANALYZED_EXPOS_UI-TOT_EXPOSURE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TEMS_ANALYZED_EXPOS_UI-TOT_EXPOSURE_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HEDGE_PLAN_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TEMS_ANALYZED_EXPOS_UI-HEDGE_PLAN_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TEMS_ANALYZED_EXPOS_UI-HEDGE_PLAN_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRANSACTION_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TEMS_ANALYZED_EXPOS_UI-TRANSACTION_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TEMS_ANALYZED_EXPOS_UI-TRANSACTION_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TEMS_ANALYZED_EXPOS_UI_STR,
EXPOSURE_ID TYPE STRING,
EXPOSURE_ORIGIN TYPE STRING,
LOG_SYSTEM TYPE STRING,
PLANNING_PERIOD TYPE STRING,
PLANNING_YEAR TYPE STRING,
DUE_DATE TYPE STRING,
TRANSACTION_CAT TYPE STRING,
SIGN TYPE STRING,
COMPANY_CODE TYPE STRING,
COUNTRY TYPE STRING,
ATTRIBUTE_01 TYPE STRING,
ATTRIBUTE_02 TYPE STRING,
ATTRIBUTE_03 TYPE STRING,
ATTRIBUTE_04 TYPE STRING,
ATTRIBUTE_05 TYPE STRING,
ATTRIBUTE_06 TYPE STRING,
TRANSACTION_CAT_TEXT TYPE STRING,
COMPANY_CODE_TEXT TYPE STRING,
COUNTRY_TEXT TYPE STRING,
ATTRIBUTE_01_TEXT TYPE STRING,
ATTRIBUTE_02_TEXT TYPE STRING,
ATTRIBUTE_03_TEXT TYPE STRING,
ATTRIBUTE_04_TEXT TYPE STRING,
ATTRIBUTE_05_TEXT TYPE STRING,
ATTRIBUTE_06_TEXT TYPE STRING,
FOREIGN_AMT TYPE STRING,
FOREIGN_CURR TYPE STRING,
DESCRIPTION TYPE STRING,
REFERENCE TYPE STRING,
PERIOD_TEXT TYPE STRING,
PERIOD_END_DATE TYPE STRING,
HORIZON TYPE STRING,
STATE TYPE STRING,
EXPOSURE_CAT TYPE STRING,
TRANSFER_CAT TYPE STRING,
TOT_EXPOSURE_ID TYPE STRING,
LAST_VERSION_HED TYPE STRING,
STATE_TEXT TYPE STRING,
EXPOSURE_CAT_TEXT TYPE STRING,
TRANSFER_CAT_TEXT TYPE STRING,
HED_COMPANY_CODE TYPE STRING,
HEDGE_PLAN_ID TYPE STRING,
HED_EXPOSURE_ID TYPE STRING,
TRANSACTION_ID TYPE STRING,
TRANSACTION_ACT TYPE STRING,
HED_COMP_CODE_TEXT TYPE STRING,
HEDGE_PLAN_TEXT TYPE STRING,
TRANSACTION_ACT_TEXT TYPE STRING,
CREATION_DATE TYPE STRING,
CREATION_TIME TYPE STRING,
CREATION_USER TYPE STRING,
CREATION_TCODE TYPE STRING,
LASTCHANGE_DATE TYPE STRING,
LASTCHANGE_TIME TYPE STRING,
LASTCHANGE_USER TYPE STRING,
LASTCHANGE_TCODE TYPE STRING,
PERCENTAGE TYPE STRING,
PERCENTAGE_MIN TYPE STRING,
MINIMUM_AMT TYPE STRING,
HM_FOREIGN_AMT TYPE STRING,
FOREIGN_AMT_TO_HEDGE TYPE STRING,
FOREIGN_AMT_MIN_TO_HEDGE TYPE STRING,
FOREIGN_AMT_HEDGED TYPE STRING,
CURR_PERCENTAGE TYPE STRING,
CURR_PERCENTAGE_MIN TYPE STRING,
CURR_MINIMUM_AMT TYPE STRING,
ACT_HEDGE_RATIO TYPE STRING,
OLD_FOREIGN_AMT TYPE STRING,
OLD_PERCENTAGE TYPE STRING,
OLD_PERCENTAGE_MIN TYPE STRING,
OLD_MINIMUM_AMT TYPE STRING,
MESSAGE_INDICATOR TYPE STRING,
D_FOREIGN_AMT TYPE STRING,
D_FOREIGN_AMT_TO_HEDGE TYPE STRING,
D_FOREIGN_AMT_MIN_TO_HEDGE TYPE STRING,
FOREIGN_AMT_S TYPE STRING,
HM_FOREIGN_AMT_S TYPE STRING,
CURR_MINIMUM_AMT_S TYPE STRING,
MINIMUM_AMT_S TYPE STRING,
FOREIGN_AMT_TO_HEDGE_S TYPE STRING,
FOREIGN_AMT_MIN_TO_HEDGE_S TYPE STRING,
FOREIGN_AMT_HEDGED_S TYPE STRING,
OLD_FOREIGN_AMT_S TYPE STRING,
OLD_MINIMUM_AMT_S TYPE STRING,
D_FOREIGN_AMT_S TYPE STRING,
D_FOREIGN_AMT_TO_HEDGE_S TYPE STRING,
D_FOREIGN_AMT_MIN_TO_HEDGE_S TYPE STRING,
COLOR TYPE STRING,
ICON TYPE STRING,
MARK TYPE STRING,END OF T_EKKO_STR. DATA: WA_TEMS_ANALYZED_EXPOS_UI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-EXPOSURE_ID sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-EXPOSURE_ORIGIN sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-LOG_SYSTEM sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-PLANNING_PERIOD sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-PLANNING_YEAR sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-DUE_DATE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-TRANSACTION_CAT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-SIGN sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-COMPANY_CODE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-COUNTRY sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_01 sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_02 sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_03 sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_04 sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_05 sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_06 sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-TRANSACTION_CAT_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-COMPANY_CODE_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-COUNTRY_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_01_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_02_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_03_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_04_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_05_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ATTRIBUTE_06_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-FOREIGN_AMT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-FOREIGN_CURR sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-DESCRIPTION sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-REFERENCE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-PERIOD_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-PERIOD_END_DATE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-HORIZON sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-STATE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-EXPOSURE_CAT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-TRANSFER_CAT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-TOT_EXPOSURE_ID sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-LAST_VERSION_HED sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-STATE_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-EXPOSURE_CAT_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-TRANSFER_CAT_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-HED_COMPANY_CODE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-HEDGE_PLAN_ID sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-HED_EXPOSURE_ID sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-TRANSACTION_ID sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-TRANSACTION_ACT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-HED_COMP_CODE_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-HEDGE_PLAN_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-TRANSACTION_ACT_TEXT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-CREATION_DATE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-CREATION_TIME sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-CREATION_USER sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-CREATION_TCODE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-LASTCHANGE_DATE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-LASTCHANGE_TIME sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-LASTCHANGE_USER sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-LASTCHANGE_TCODE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-PERCENTAGE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-PERCENTAGE_MIN sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-MINIMUM_AMT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-HM_FOREIGN_AMT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-FOREIGN_AMT_TO_HEDGE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-FOREIGN_AMT_MIN_TO_HEDGE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-FOREIGN_AMT_HEDGED sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-CURR_PERCENTAGE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-CURR_PERCENTAGE_MIN sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-CURR_MINIMUM_AMT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ACT_HEDGE_RATIO sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-OLD_FOREIGN_AMT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-OLD_PERCENTAGE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-OLD_PERCENTAGE_MIN sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-OLD_MINIMUM_AMT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-MESSAGE_INDICATOR sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-D_FOREIGN_AMT sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-D_FOREIGN_AMT_TO_HEDGE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-D_FOREIGN_AMT_MIN_TO_HEDGE sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-FOREIGN_AMT_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-HM_FOREIGN_AMT_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-CURR_MINIMUM_AMT_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-MINIMUM_AMT_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-FOREIGN_AMT_TO_HEDGE_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-FOREIGN_AMT_MIN_TO_HEDGE_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-FOREIGN_AMT_HEDGED_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-OLD_FOREIGN_AMT_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-OLD_MINIMUM_AMT_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-D_FOREIGN_AMT_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-D_FOREIGN_AMT_TO_HEDGE_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-D_FOREIGN_AMT_MIN_TO_HEDGE_S sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-COLOR sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-ICON sy-vline
WA_TEMS_ANALYZED_EXPOS_UI_STR-MARK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.