ABAP Select data from SAP table TDS_SLS_TEMPLATE_ITEM_GUID into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TDS_SLS_TEMPLATE_ITEM_GUID table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TDS_SLS_TEMPLATE_ITEM_GUID. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TDS_SLS_TEMPLATE_ITEM_GUID table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TDS_SLS_TEMPLATE_ITEM_GUID TYPE STANDARD TABLE OF TDS_SLS_TEMPLATE_ITEM_GUID,
      WA_TDS_SLS_TEMPLATE_ITEM_GUID TYPE TDS_SLS_TEMPLATE_ITEM_GUID,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TDS_SLS_TEMPLATE_ITEM_GUID> TYPE TDS_SLS_TEMPLATE_ITEM_GUID.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TDS_SLS_TEMPLATE_ITEM_GUID.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TDS_SLS_TEMPLATE_ITEM_GUID
  INTO TABLE IT_TDS_SLS_TEMPLATE_ITEM_GUID.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TDS_SLS_TEMPLATE_ITEM_GUID
*  INTO TABLE @DATA(IT_TDS_SLS_TEMPLATE_ITEM_GUID2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TDS_SLS_TEMPLATE_ITEM_GUID INDEX 1 INTO DATA(WA_TDS_SLS_TEMPLATE_ITEM_GUID2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TDS_SLS_TEMPLATE_ITEM_GUID ASSIGNING <TDS_SLS_TEMPLATE_ITEM_GUID>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TDS_SLS_TEMPLATE_ITEM_GUID>-GUID = 1.
<TDS_SLS_TEMPLATE_ITEM_GUID>-GUID_HEAD = 1.
<TDS_SLS_TEMPLATE_ITEM_GUID>-SEQUENCE = 1.
<TDS_SLS_TEMPLATE_ITEM_GUID>-ERROR_STATE = 1.
<TDS_SLS_TEMPLATE_ITEM_GUID>-VALID_TO = 1.
ENDLOOP.

LOOP AT IT_TDS_SLS_TEMPLATE_ITEM_GUID INTO WA_TDS_SLS_TEMPLATE_ITEM_GUID.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TDS_SLS_TEMPLATE_ITEM_GUID-MATNR, sy-vline,
WA_TDS_SLS_TEMPLATE_ITEM_GUID-EAN11, sy-vline,
WA_TDS_SLS_TEMPLATE_ITEM_GUID-KWMENG, sy-vline,
WA_TDS_SLS_TEMPLATE_ITEM_GUID-VRKME, sy-vline,
WA_TDS_SLS_TEMPLATE_ITEM_GUID-ARKTX, sy-vline,
WA_TDS_SLS_TEMPLATE_ITEM_GUID-WERKS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TDS_SLS_TEMPLATE_ITEM_GUID you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TDS_SLS_TEMPLATE_ITEM_GUID TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TDS_SLS_TEMPLATE_ITEM_GUID INTO WA_TDS_SLS_TEMPLATE_ITEM_GUID. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_TDS_SLS_TEMPLATE_ITEM_GUID-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TDS_SLS_TEMPLATE_ITEM_GUID-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EAN11, internal->external for field EAN11 CALL FUNCTION 'CONVERSION_EXIT_EAN11_OUTPUT' EXPORTING input = WA_TDS_SLS_TEMPLATE_ITEM_GUID-EAN11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TDS_SLS_TEMPLATE_ITEM_GUID-EAN11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_TDS_SLS_TEMPLATE_ITEM_GUID-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TDS_SLS_TEMPLATE_ITEM_GUID-VRKME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TDS_SLS_TEMPLATE_ITEM_GUID_STR,
GUID TYPE STRING,
GUID_HEAD TYPE STRING,
SEQUENCE TYPE STRING,
ERROR_STATE TYPE STRING,
VALID_TO TYPE STRING,
MATNR TYPE STRING,
EAN11 TYPE STRING,
KWMENG TYPE STRING,
VRKME TYPE STRING,
ARKTX TYPE STRING,
WERKS TYPE STRING,
DLV_DATE TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_AT TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_AT TYPE STRING,END OF T_EKKO_STR. DATA: WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-GUID sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-GUID_HEAD sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-SEQUENCE sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-ERROR_STATE sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-VALID_TO sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-MATNR sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-EAN11 sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-KWMENG sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-VRKME sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-ARKTX sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-WERKS sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-DLV_DATE sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-CREATED_BY sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-CREATED_AT sy-vline
WA_TDS_SLS_TEMPLATE_ITEM_GUID_STR-CHANGED_BY sy-vline