ABAP Select data from SAP table TDS_RFC_FPLT_COMC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TDS_RFC_FPLT_COMC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TDS_RFC_FPLT_COMC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TDS_RFC_FPLT_COMC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TDS_RFC_FPLT_COMC TYPE STANDARD TABLE OF TDS_RFC_FPLT_COMC,
      WA_TDS_RFC_FPLT_COMC TYPE TDS_RFC_FPLT_COMC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TDS_RFC_FPLT_COMC> TYPE TDS_RFC_FPLT_COMC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TDS_RFC_FPLT_COMC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TDS_RFC_FPLT_COMC
  INTO TABLE IT_TDS_RFC_FPLT_COMC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TDS_RFC_FPLT_COMC
*  INTO TABLE @DATA(IT_TDS_RFC_FPLT_COMC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TDS_RFC_FPLT_COMC INDEX 1 INTO DATA(WA_TDS_RFC_FPLT_COMC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TDS_RFC_FPLT_COMC ASSIGNING <TDS_RFC_FPLT_COMC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TDS_RFC_FPLT_COMC>-HANDLE = 1.
<TDS_RFC_FPLT_COMC>-FPLTR = 1.
<TDS_RFC_FPLT_COMC>-ABRBE = 1.
<TDS_RFC_FPLT_COMC>-ABREN = 1.
<TDS_RFC_FPLT_COMC>-AFDAT = 1.
ENDLOOP.

LOOP AT IT_TDS_RFC_FPLT_COMC INTO WA_TDS_RFC_FPLT_COMC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TDS_RFC_FPLT_COMC-FAKWR, sy-vline,
WA_TDS_RFC_FPLT_COMC-FAKWR_EXT, sy-vline,
WA_TDS_RFC_FPLT_COMC-WAERS, sy-vline,
WA_TDS_RFC_FPLT_COMC-FAKSP, sy-vline,
WA_TDS_RFC_FPLT_COMC-TEMAN, sy-vline,
WA_TDS_RFC_FPLT_COMC-ZTERM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TDS_RFC_FPLT_COMC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TDS_RFC_FPLT_COMC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TDS_RFC_FPLT_COMC INTO WA_TDS_RFC_FPLT_COMC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TDS_RFC_FPLT_COMC_STR,
HANDLE TYPE STRING,
FPLTR TYPE STRING,
ABRBE TYPE STRING,
ABREN TYPE STRING,
AFDAT TYPE STRING,
FAKWR TYPE STRING,
FAKWR_EXT TYPE STRING,
WAERS TYPE STRING,
FAKSP TYPE STRING,
TEMAN TYPE STRING,
ZTERM TYPE STRING,
FPTTP TYPE STRING,
FKARV TYPE STRING,
FAKCA TYPE STRING,
TETXT TYPE STRING,
MLBEZ TYPE STRING,
FPROZ TYPE STRING,
FPROZ_EXT TYPE STRING,
FAREG TYPE STRING,
KURRF TYPE STRING,
KURRF_EXT TYPE STRING,
FPFIX TYPE STRING,END OF T_EKKO_STR. DATA: WA_TDS_RFC_FPLT_COMC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TDS_RFC_FPLT_COMC_STR-HANDLE sy-vline
WA_TDS_RFC_FPLT_COMC_STR-FPLTR sy-vline
WA_TDS_RFC_FPLT_COMC_STR-ABRBE sy-vline
WA_TDS_RFC_FPLT_COMC_STR-ABREN sy-vline
WA_TDS_RFC_FPLT_COMC_STR-AFDAT sy-vline
WA_TDS_RFC_FPLT_COMC_STR-FAKWR sy-vline
WA_TDS_RFC_FPLT_COMC_STR-FAKWR_EXT sy-vline
WA_TDS_RFC_FPLT_COMC_STR-WAERS sy-vline
WA_TDS_RFC_FPLT_COMC_STR-FAKSP sy-vline
WA_TDS_RFC_FPLT_COMC_STR-TEMAN sy-vline
WA_TDS_RFC_FPLT_COMC_STR-ZTERM sy-vline
WA_TDS_RFC_FPLT_COMC_STR-FPTTP sy-vline
WA_TDS_RFC_FPLT_COMC_STR-FKARV sy-vline
WA_TDS_RFC_FPLT_COMC_STR-FAKCA sy-vline
WA_TDS_RFC_FPLT_COMC_STR-TETXT sy-vline
WA_TDS_RFC_FPLT_COMC_STR-MLBEZ sy-vline
WA_TDS_RFC_FPLT_COMC_STR-FPROZ sy-vline
WA_TDS_RFC_FPLT_COMC_STR-FPROZ_EXT sy-vline
WA_TDS_RFC_FPLT_COMC_STR-FAREG sy-vline
WA_TDS_RFC_FPLT_COMC_STR-KURRF sy-vline
WA_TDS_RFC_FPLT_COMC_STR-KURRF_EXT sy-vline
WA_TDS_RFC_FPLT_COMC_STR-FPFIX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.