ABAP Select data from SAP table TDS_ME_OA_SA_RL_SUPPLIERADDR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TDS_ME_OA_SA_RL_SUPPLIERADDR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TDS_ME_OA_SA_RL_SUPPLIERADDR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TDS_ME_OA_SA_RL_SUPPLIERADDR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TDS_ME_OA_SA_RL_SUPPLIERADDR TYPE STANDARD TABLE OF TDS_ME_OA_SA_RL_SUPPLIERADDR,
      WA_TDS_ME_OA_SA_RL_SUPPLIERADDR TYPE TDS_ME_OA_SA_RL_SUPPLIERADDR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TDS_ME_OA_SA_RL_SUPPLIERADDR> TYPE TDS_ME_OA_SA_RL_SUPPLIERADDR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TDS_ME_OA_SA_RL_SUPPLIERADDR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TDS_ME_OA_SA_RL_SUPPLIERADDR
  INTO TABLE IT_TDS_ME_OA_SA_RL_SUPPLIERADDR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TDS_ME_OA_SA_RL_SUPPLIERADDR
*  INTO TABLE @DATA(IT_TDS_ME_OA_SA_RL_SUPPLIERADDR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TDS_ME_OA_SA_RL_SUPPLIERADDR INDEX 1 INTO DATA(WA_TDS_ME_OA_SA_RL_SUPPLIERADDR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TDS_ME_OA_SA_RL_SUPPLIERADDR ASSIGNING <TDS_ME_OA_SA_RL_SUPPLIERADDR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TDS_ME_OA_SA_RL_SUPPLIERADDR>-MANDT = 1.
<TDS_ME_OA_SA_RL_SUPPLIERADDR>-SUPPLIER = 1.
<TDS_ME_OA_SA_RL_SUPPLIERADDR>-SUPPLIERNAME = 1.
<TDS_ME_OA_SA_RL_SUPPLIERADDR>-SUPPLIERADDRESSID = 1.
<TDS_ME_OA_SA_RL_SUPPLIERADDR>-ADDRESSLINE1 = 1.
ENDLOOP.

LOOP AT IT_TDS_ME_OA_SA_RL_SUPPLIERADDR INTO WA_TDS_ME_OA_SA_RL_SUPPLIERADDR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-ADDRESSLINE2, sy-vline,
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-ADDRESSLINE3, sy-vline,
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-ADDRESSLINE4, sy-vline,
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-ADDRESSLINE5, sy-vline,
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-ADDRESSLINE6, sy-vline,
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-ADDRESSLINE7, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TDS_ME_OA_SA_RL_SUPPLIERADDR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TDS_ME_OA_SA_RL_SUPPLIERADDR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TDS_ME_OA_SA_RL_SUPPLIERADDR INTO WA_TDS_ME_OA_SA_RL_SUPPLIERADDR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-SUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-SUPPLIER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPPLIERADDRESSID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-SUPPLIERADDRESSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-SUPPLIERADDRESSID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SXIDN, internal->external for field EMAILADDRESS CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-EMAILADDRESS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TDS_ME_OA_SA_RL_SUPPLIERADDR-EMAILADDRESS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR,
MANDT TYPE STRING,
SUPPLIER TYPE STRING,
SUPPLIERNAME TYPE STRING,
SUPPLIERADDRESSID TYPE STRING,
ADDRESSLINE1 TYPE STRING,
ADDRESSLINE2 TYPE STRING,
ADDRESSLINE3 TYPE STRING,
ADDRESSLINE4 TYPE STRING,
ADDRESSLINE5 TYPE STRING,
ADDRESSLINE6 TYPE STRING,
ADDRESSLINE7 TYPE STRING,
ADDRESSLINE8 TYPE STRING,
VATREGISTRATION TYPE STRING,
FAXNUMBER TYPE STRING,
PHONENUMBER1 TYPE STRING,
EMAILADDRESS TYPE STRING,END OF T_EKKO_STR. DATA: WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-MANDT sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-SUPPLIER sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-SUPPLIERNAME sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-SUPPLIERADDRESSID sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-ADDRESSLINE1 sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-ADDRESSLINE2 sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-ADDRESSLINE3 sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-ADDRESSLINE4 sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-ADDRESSLINE5 sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-ADDRESSLINE6 sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-ADDRESSLINE7 sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-ADDRESSLINE8 sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-VATREGISTRATION sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-FAXNUMBER sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-PHONENUMBER1 sy-vline
WA_TDS_ME_OA_SA_RL_SUPPLIERADDR_STR-EMAILADDRESS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.