ABAP Select data from SAP table TDS_GOAL_SCHDA_SLINE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TDS_GOAL_SCHDA_SLINE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TDS_GOAL_SCHDA_SLINE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TDS_GOAL_SCHDA_SLINE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TDS_GOAL_SCHDA_SLINE TYPE STANDARD TABLE OF TDS_GOAL_SCHDA_SLINE,
      WA_TDS_GOAL_SCHDA_SLINE TYPE TDS_GOAL_SCHDA_SLINE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TDS_GOAL_SCHDA_SLINE> TYPE TDS_GOAL_SCHDA_SLINE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TDS_GOAL_SCHDA_SLINE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TDS_GOAL_SCHDA_SLINE
  INTO TABLE IT_TDS_GOAL_SCHDA_SLINE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TDS_GOAL_SCHDA_SLINE
*  INTO TABLE @DATA(IT_TDS_GOAL_SCHDA_SLINE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TDS_GOAL_SCHDA_SLINE INDEX 1 INTO DATA(WA_TDS_GOAL_SCHDA_SLINE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TDS_GOAL_SCHDA_SLINE ASSIGNING <TDS_GOAL_SCHDA_SLINE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TDS_GOAL_SCHDA_SLINE>-HANDLE = 1.
<TDS_GOAL_SCHDA_SLINE>-SLINE_ID = 1.
<TDS_GOAL_SCHDA_SLINE>-SCHDA_RELEASE_TYPE = 1.
<TDS_GOAL_SCHDA_SLINE>-CATEGORY_CODE = 1.
<TDS_GOAL_SCHDA_SLINE>-SLINE_DATE_CATEGORY = 1.
ENDLOOP.

LOOP AT IT_TDS_GOAL_SCHDA_SLINE INTO WA_TDS_GOAL_SCHDA_SLINE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TDS_GOAL_SCHDA_SLINE-SLINE_DATE, sy-vline,
WA_TDS_GOAL_SCHDA_SLINE-SLINE_TIME, sy-vline,
WA_TDS_GOAL_SCHDA_SLINE-ORDER_QTY, sy-vline,
WA_TDS_GOAL_SCHDA_SLINE-REQUIRED_QTY, sy-vline,
WA_TDS_GOAL_SCHDA_SLINE-CORRECTED_QTY, sy-vline,
WA_TDS_GOAL_SCHDA_SLINE-CONFIRMED_QTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TDS_GOAL_SCHDA_SLINE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TDS_GOAL_SCHDA_SLINE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TDS_GOAL_SCHDA_SLINE INTO WA_TDS_GOAL_SCHDA_SLINE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field SALES_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_TDS_GOAL_SCHDA_SLINE-SALES_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TDS_GOAL_SCHDA_SLINE-SALES_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TDS_GOAL_SCHDA_SLINE_STR,
HANDLE TYPE STRING,
SLINE_ID TYPE STRING,
SCHDA_RELEASE_TYPE TYPE STRING,
CATEGORY_CODE TYPE STRING,
SLINE_DATE_CATEGORY TYPE STRING,
SLINE_DATE TYPE STRING,
SLINE_TIME TYPE STRING,
ORDER_QTY TYPE STRING,
REQUIRED_QTY TYPE STRING,
CORRECTED_QTY TYPE STRING,
CONFIRMED_QTY TYPE STRING,
OPEN_QTY TYPE STRING,
CUMULATIVE_RELEASED_QTY TYPE STRING,
SLINE_TYPE_EDI TYPE STRING,
DELIVERY_BLOCK_CODE TYPE STRING,
CUST_ENGINEER_CHANGE_STATUS TYPE STRING,
BOM_EXPLOSION_NUMBER TYPE STRING,
GOODS_ISSUE_DATE TYPE STRING,
GOODS_ISSUE_TIME TYPE STRING,
LOADING_DATE TYPE STRING,
LOADING_TIME TYPE STRING,
MATERIAL_AVAILABILITY_DATE TYPE STRING,
MATERIAL_AVAILABILITY_TIME TYPE STRING,
TRANSPORTATION_PLANNING_DATE TYPE STRING,
TRANSPORTATION_PLANNING_TIME TYPE STRING,
HANDOVER_DATE TYPE STRING,
HANDOVER_TIME TYPE STRING,
ROUTE_SCHEDULE TYPE STRING,
MOVE_TYPE TYPE STRING,
UPDATE_INDICATOR TYPE STRING,
SALES_UOM TYPE STRING,
ETDAT TYPE STRING,
DUMMY_SLSDOCSCHEDL_INCL_EEW_PS TYPE STRING,END OF T_EKKO_STR. DATA: WA_TDS_GOAL_SCHDA_SLINE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-HANDLE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-SLINE_ID sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-SCHDA_RELEASE_TYPE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-CATEGORY_CODE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-SLINE_DATE_CATEGORY sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-SLINE_DATE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-SLINE_TIME sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-ORDER_QTY sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-REQUIRED_QTY sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-CORRECTED_QTY sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-CONFIRMED_QTY sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-OPEN_QTY sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-CUMULATIVE_RELEASED_QTY sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-SLINE_TYPE_EDI sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-DELIVERY_BLOCK_CODE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-CUST_ENGINEER_CHANGE_STATUS sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-BOM_EXPLOSION_NUMBER sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-GOODS_ISSUE_DATE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-GOODS_ISSUE_TIME sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-LOADING_DATE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-LOADING_TIME sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-MATERIAL_AVAILABILITY_DATE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-MATERIAL_AVAILABILITY_TIME sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-TRANSPORTATION_PLANNING_DATE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-TRANSPORTATION_PLANNING_TIME sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-HANDOVER_DATE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-HANDOVER_TIME sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-ROUTE_SCHEDULE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-MOVE_TYPE sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-UPDATE_INDICATOR sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-SALES_UOM sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-ETDAT sy-vline
WA_TDS_GOAL_SCHDA_SLINE_STR-DUMMY_SLSDOCSCHEDL_INCL_EEW_PS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.