ABAP Select data from SAP table TDS_COND_COMR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TDS_COND_COMR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TDS_COND_COMR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TDS_COND_COMR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TDS_COND_COMR TYPE STANDARD TABLE OF TDS_COND_COMR,
      WA_TDS_COND_COMR TYPE TDS_COND_COMR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TDS_COND_COMR> TYPE TDS_COND_COMR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TDS_COND_COMR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TDS_COND_COMR
  INTO TABLE IT_TDS_COND_COMR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TDS_COND_COMR
*  INTO TABLE @DATA(IT_TDS_COND_COMR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TDS_COND_COMR INDEX 1 INTO DATA(WA_TDS_COND_COMR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TDS_COND_COMR ASSIGNING <TDS_COND_COMR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TDS_COND_COMR>-HANDLE = 1.
<TDS_COND_COMR>-KSCHL_T = 1.
<TDS_COND_COMR>-KINAK_T = 1.
<TDS_COND_COMR>-KRECH_R = 1.
<TDS_COND_COMR>-KRECH_T = 1.
ENDLOOP.

LOOP AT IT_TDS_COND_COMR INTO WA_TDS_COND_COMR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TDS_COND_COMR-KNTYP_R, sy-vline,
WA_TDS_COND_COMR-KNTYP_T, sy-vline,
WA_TDS_COND_COMR-KSTEU_R, sy-vline,
WA_TDS_COND_COMR-KSTEU_T, sy-vline,
WA_TDS_COND_COMR-KHERK_R, sy-vline,
WA_TDS_COND_COMR-KHERK_T, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TDS_COND_COMR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TDS_COND_COMR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TDS_COND_COMR INTO WA_TDS_COND_COMR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KNUMA_BO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TDS_COND_COMR-KNUMA_BO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TDS_COND_COMR-KNUMA_BO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TDS_COND_COMR_STR,
HANDLE TYPE STRING,
KSCHL_T TYPE STRING,
KINAK_T TYPE STRING,
KRECH_R TYPE STRING,
KRECH_T TYPE STRING,
KNTYP_R TYPE STRING,
KNTYP_T TYPE STRING,
KSTEU_R TYPE STRING,
KSTEU_T TYPE STRING,
KHERK_R TYPE STRING,
KHERK_T TYPE STRING,
KZBZG_R TYPE STRING,
KZBZG_T TYPE STRING,
KOAID_R TYPE STRING,
KOAID_T TYPE STRING,
KMPRS TYPE STRING,
KNUMA_BO TYPE STRING,
KDATU TYPE STRING,
KSTAT TYPE STRING,
KWERT_K TYPE STRING,
KWAEH TYPE STRING,
AWEI1 TYPE STRING,
AWEIN TYPE STRING,
KAWRT TYPE STRING,END OF T_EKKO_STR. DATA: WA_TDS_COND_COMR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TDS_COND_COMR_STR-HANDLE sy-vline
WA_TDS_COND_COMR_STR-KSCHL_T sy-vline
WA_TDS_COND_COMR_STR-KINAK_T sy-vline
WA_TDS_COND_COMR_STR-KRECH_R sy-vline
WA_TDS_COND_COMR_STR-KRECH_T sy-vline
WA_TDS_COND_COMR_STR-KNTYP_R sy-vline
WA_TDS_COND_COMR_STR-KNTYP_T sy-vline
WA_TDS_COND_COMR_STR-KSTEU_R sy-vline
WA_TDS_COND_COMR_STR-KSTEU_T sy-vline
WA_TDS_COND_COMR_STR-KHERK_R sy-vline
WA_TDS_COND_COMR_STR-KHERK_T sy-vline
WA_TDS_COND_COMR_STR-KZBZG_R sy-vline
WA_TDS_COND_COMR_STR-KZBZG_T sy-vline
WA_TDS_COND_COMR_STR-KOAID_R sy-vline
WA_TDS_COND_COMR_STR-KOAID_T sy-vline
WA_TDS_COND_COMR_STR-KMPRS sy-vline
WA_TDS_COND_COMR_STR-KNUMA_BO sy-vline
WA_TDS_COND_COMR_STR-KDATU sy-vline
WA_TDS_COND_COMR_STR-KSTAT sy-vline
WA_TDS_COND_COMR_STR-KWERT_K sy-vline
WA_TDS_COND_COMR_STR-KWAEH sy-vline
WA_TDS_COND_COMR_STR-AWEI1 sy-vline
WA_TDS_COND_COMR_STR-AWEIN sy-vline
WA_TDS_COND_COMR_STR-KAWRT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.