ABAP Select data from SAP table TCNVF_1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TCNVF_1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TCNVF_1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TCNVF_1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TCNVF_1 TYPE STANDARD TABLE OF TCNVF_1,
      WA_TCNVF_1 TYPE TCNVF_1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TCNVF_1> TYPE TCNVF_1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TCNVF_1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TCNVF_1
  INTO TABLE IT_TCNVF_1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TCNVF_1
*  INTO TABLE @DATA(IT_TCNVF_12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TCNVF_1 INDEX 1 INTO DATA(WA_TCNVF_12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TCNVF_1 ASSIGNING <TCNVF_1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TCNVF_1>-MANDT = 1.
<TCNVF_1>-APPLIC = 1.
<TCNVF_1>-SUBAPP = 1.
<TCNVF_1>-LSTVAR = 1.
<TCNVF_1>-LINTYP = 1.
ENDLOOP.

LOOP AT IT_TCNVF_1 INTO WA_TCNVF_1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TCNVF_1-OBJECT, sy-vline,
WA_TCNVF_1-LINE, sy-vline,
WA_TCNVF_1-POSIT, sy-vline,
WA_TCNVF_1-FIELD, sy-vline,
WA_TCNVF_1-FDLEN, sy-vline,
WA_TCNVF_1-FDTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TCNVF_1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TCNVF_1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TCNVF_1 INTO WA_TCNVF_1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit DTYPE, internal->external for field DATATYPE CALL FUNCTION 'CONVERSION_EXIT_DTYPE_OUTPUT' EXPORTING input = WA_TCNVF_1-DATATYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TCNVF_1-DATATYPE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TCNVF_1_STR,
MANDT TYPE STRING,
APPLIC TYPE STRING,
SUBAPP TYPE STRING,
LSTVAR TYPE STRING,
LINTYP TYPE STRING,
OBJECT TYPE STRING,
LINE TYPE STRING,
POSIT TYPE STRING,
FIELD TYPE STRING,
FDLEN TYPE STRING,
FDTYPE TYPE STRING,
ODECIMALS TYPE STRING,
EDITMASK TYPE STRING,
NOINIT TYPE STRING,
STDATR TYPE STRING,
COLOR TYPE STRING,
INTENS TYPE STRING,
INVERS TYPE STRING,
INPUT TYPE STRING,
HOTSPOT TYPE STRING,
ENDPOS TYPE STRING,
TABNAME TYPE STRING,
FIELDNAME TYPE STRING,
MTCODE TYPE STRING,
CURKEY TYPE STRING,
DATATYPE TYPE STRING,
KTEXT TYPE STRING,
FIELDNR TYPE STRING,
CURKEYNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_TCNVF_1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TCNVF_1_STR-MANDT sy-vline
WA_TCNVF_1_STR-APPLIC sy-vline
WA_TCNVF_1_STR-SUBAPP sy-vline
WA_TCNVF_1_STR-LSTVAR sy-vline
WA_TCNVF_1_STR-LINTYP sy-vline
WA_TCNVF_1_STR-OBJECT sy-vline
WA_TCNVF_1_STR-LINE sy-vline
WA_TCNVF_1_STR-POSIT sy-vline
WA_TCNVF_1_STR-FIELD sy-vline
WA_TCNVF_1_STR-FDLEN sy-vline
WA_TCNVF_1_STR-FDTYPE sy-vline
WA_TCNVF_1_STR-ODECIMALS sy-vline
WA_TCNVF_1_STR-EDITMASK sy-vline
WA_TCNVF_1_STR-NOINIT sy-vline
WA_TCNVF_1_STR-STDATR sy-vline
WA_TCNVF_1_STR-COLOR sy-vline
WA_TCNVF_1_STR-INTENS sy-vline
WA_TCNVF_1_STR-INVERS sy-vline
WA_TCNVF_1_STR-INPUT sy-vline
WA_TCNVF_1_STR-HOTSPOT sy-vline
WA_TCNVF_1_STR-ENDPOS sy-vline
WA_TCNVF_1_STR-TABNAME sy-vline
WA_TCNVF_1_STR-FIELDNAME sy-vline
WA_TCNVF_1_STR-MTCODE sy-vline
WA_TCNVF_1_STR-CURKEY sy-vline
WA_TCNVF_1_STR-DATATYPE sy-vline
WA_TCNVF_1_STR-KTEXT sy-vline
WA_TCNVF_1_STR-FIELDNR sy-vline
WA_TCNVF_1_STR-CURKEYNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.