ABAP Select data from SAP table TC50E into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TC50E table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TC50E. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TC50E table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TC50E TYPE STANDARD TABLE OF TC50E,
      WA_TC50E TYPE TC50E,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TC50E> TYPE TC50E.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TC50E.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TC50E
  INTO TABLE IT_TC50E.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TC50E
*  INTO TABLE @DATA(IT_TC50E2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TC50E INDEX 1 INTO DATA(WA_TC50E2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TC50E ASSIGNING <TC50E>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TC50E>-MANDT = 1.
<TC50E>-WERKS = 1.
<TC50E>-CSTYP = 1.
<TC50E>-COSTR = 1.
<TC50E>-ATINN = 1.
ENDLOOP.

LOOP AT IT_TC50E INTO WA_TC50E.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TC50E-MKMZL, sy-vline,
WA_TC50E-WRTKZ, sy-vline,
WA_TC50E-ATWRT, sy-vline,
WA_TC50E-ATFLV, sy-vline,
WA_TC50E-ATFLB, sy-vline,
WA_TC50E-ATAWE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TC50E you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TC50E TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TC50E INTO WA_TC50E. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ATINN, internal->external for field ATINN CALL FUNCTION 'CONVERSION_EXIT_ATINN_OUTPUT' EXPORTING input = WA_TC50E-ATINN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TC50E-ATINN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ATAWE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_TC50E-ATAWE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TC50E-ATAWE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ATAW1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_TC50E-ATAW1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TC50E-ATAW1.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TC50E_STR,
MANDT TYPE STRING,
WERKS TYPE STRING,
CSTYP TYPE STRING,
COSTR TYPE STRING,
ATINN TYPE STRING,
MKMZL TYPE STRING,
WRTKZ TYPE STRING,
ATWRT TYPE STRING,
ATFLV TYPE STRING,
ATFLB TYPE STRING,
ATAWE TYPE STRING,
ATAW1 TYPE STRING,
ATCOD TYPE STRING,
ATFOR TYPE STRING,
FVLNR TYPE STRING,
OBLKZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_TC50E_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TC50E_STR-MANDT sy-vline
WA_TC50E_STR-WERKS sy-vline
WA_TC50E_STR-CSTYP sy-vline
WA_TC50E_STR-COSTR sy-vline
WA_TC50E_STR-ATINN sy-vline
WA_TC50E_STR-MKMZL sy-vline
WA_TC50E_STR-WRTKZ sy-vline
WA_TC50E_STR-ATWRT sy-vline
WA_TC50E_STR-ATFLV sy-vline
WA_TC50E_STR-ATFLB sy-vline
WA_TC50E_STR-ATAWE sy-vline
WA_TC50E_STR-ATAW1 sy-vline
WA_TC50E_STR-ATCOD sy-vline
WA_TC50E_STR-ATFOR sy-vline
WA_TC50E_STR-FVLNR sy-vline
WA_TC50E_STR-OBLKZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.