ABAP Select data from SAP table T8PSA_LIFT_VOL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T8PSA_LIFT_VOL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T8PSA_LIFT_VOL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T8PSA_LIFT_VOL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T8PSA_LIFT_VOL TYPE STANDARD TABLE OF T8PSA_LIFT_VOL,
      WA_T8PSA_LIFT_VOL TYPE T8PSA_LIFT_VOL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T8PSA_LIFT_VOL> TYPE T8PSA_LIFT_VOL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T8PSA_LIFT_VOL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T8PSA_LIFT_VOL
  INTO TABLE IT_T8PSA_LIFT_VOL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T8PSA_LIFT_VOL
*  INTO TABLE @DATA(IT_T8PSA_LIFT_VOL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T8PSA_LIFT_VOL INDEX 1 INTO DATA(WA_T8PSA_LIFT_VOL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T8PSA_LIFT_VOL ASSIGNING <T8PSA_LIFT_VOL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T8PSA_LIFT_VOL>-MANDT = 1.
<T8PSA_LIFT_VOL>-BUKRS = 1.
<T8PSA_LIFT_VOL>-PSC_NAME = 1.
<T8PSA_LIFT_VOL>-PSC_PRODUCT = 1.
<T8PSA_LIFT_VOL>-VNAME = 1.
ENDLOOP.

LOOP AT IT_T8PSA_LIFT_VOL INTO WA_T8PSA_LIFT_VOL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T8PSA_LIFT_VOL-ETYPE, sy-vline,
WA_T8PSA_LIFT_VOL-TERM, sy-vline,
WA_T8PSA_LIFT_VOL-PSC_YEAR, sy-vline,
WA_T8PSA_LIFT_VOL-PROD_DATE, sy-vline,
WA_T8PSA_LIFT_VOL-VOL_TYPE, sy-vline,
WA_T8PSA_LIFT_VOL-PARTN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T8PSA_LIFT_VOL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T8PSA_LIFT_VOL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T8PSA_LIFT_VOL INTO WA_T8PSA_LIFT_VOL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T8PSA_LIFT_VOL-VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T8PSA_LIFT_VOL-VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ETYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T8PSA_LIFT_VOL-ETYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T8PSA_LIFT_VOL-ETYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field PSC_YEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_T8PSA_LIFT_VOL-PSC_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T8PSA_LIFT_VOL-PSC_YEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T8PSA_LIFT_VOL-PARTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T8PSA_LIFT_VOL-PARTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CUSTOMER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T8PSA_LIFT_VOL-CUSTOMER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T8PSA_LIFT_VOL-CUSTOMER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFT_BY_NOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T8PSA_LIFT_VOL-LIFT_BY_NOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T8PSA_LIFT_VOL-LIFT_BY_NOC.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T8PSA_LIFT_VOL_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
PSC_NAME TYPE STRING,
PSC_PRODUCT TYPE STRING,
VNAME TYPE STRING,
ETYPE TYPE STRING,
TERM TYPE STRING,
PSC_YEAR TYPE STRING,
PROD_DATE TYPE STRING,
VOL_TYPE TYPE STRING,
PARTN TYPE STRING,
LIFT_PARTN_GROUP TYPE STRING,
SHIP_CODE TYPE STRING,
OIL_CODE TYPE STRING,
BILL_LADING TYPE STRING,
API TYPE STRING,
VOLUME TYPE STRING,
PERIOD TYPE STRING,
VOLUME_TYPE TYPE STRING,
SPLIT_BY TYPE STRING,
CUSTOMER TYPE STRING,
LIFT_BY_NOC TYPE STRING,
SALES_TYPE TYPE STRING,
PSC_PPU TYPE STRING,
PRICE_CURR TYPE STRING,END OF T_EKKO_STR. DATA: WA_T8PSA_LIFT_VOL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T8PSA_LIFT_VOL_STR-MANDT sy-vline
WA_T8PSA_LIFT_VOL_STR-BUKRS sy-vline
WA_T8PSA_LIFT_VOL_STR-PSC_NAME sy-vline
WA_T8PSA_LIFT_VOL_STR-PSC_PRODUCT sy-vline
WA_T8PSA_LIFT_VOL_STR-VNAME sy-vline
WA_T8PSA_LIFT_VOL_STR-ETYPE sy-vline
WA_T8PSA_LIFT_VOL_STR-TERM sy-vline
WA_T8PSA_LIFT_VOL_STR-PSC_YEAR sy-vline
WA_T8PSA_LIFT_VOL_STR-PROD_DATE sy-vline
WA_T8PSA_LIFT_VOL_STR-VOL_TYPE sy-vline
WA_T8PSA_LIFT_VOL_STR-PARTN sy-vline
WA_T8PSA_LIFT_VOL_STR-LIFT_PARTN_GROUP sy-vline
WA_T8PSA_LIFT_VOL_STR-SHIP_CODE sy-vline
WA_T8PSA_LIFT_VOL_STR-OIL_CODE sy-vline
WA_T8PSA_LIFT_VOL_STR-BILL_LADING sy-vline
WA_T8PSA_LIFT_VOL_STR-API sy-vline
WA_T8PSA_LIFT_VOL_STR-VOLUME sy-vline
WA_T8PSA_LIFT_VOL_STR-PERIOD sy-vline
WA_T8PSA_LIFT_VOL_STR-VOLUME_TYPE sy-vline
WA_T8PSA_LIFT_VOL_STR-SPLIT_BY sy-vline
WA_T8PSA_LIFT_VOL_STR-CUSTOMER sy-vline
WA_T8PSA_LIFT_VOL_STR-LIFT_BY_NOC sy-vline
WA_T8PSA_LIFT_VOL_STR-SALES_TYPE sy-vline
WA_T8PSA_LIFT_VOL_STR-PSC_PPU sy-vline
WA_T8PSA_LIFT_VOL_STR-PRICE_CURR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.