ABAP Select data from SAP table T7SIA5 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T7SIA5 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T7SIA5. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T7SIA5 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T7SIA5 TYPE STANDARD TABLE OF T7SIA5,
      WA_T7SIA5 TYPE T7SIA5,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T7SIA5> TYPE T7SIA5.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T7SIA5.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T7SIA5
  INTO TABLE IT_T7SIA5.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T7SIA5
*  INTO TABLE @DATA(IT_T7SIA52).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T7SIA5 INDEX 1 INTO DATA(WA_T7SIA52).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T7SIA5 ASSIGNING <T7SIA5>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T7SIA5>-MANDT = 1.
<T7SIA5>-PERNR = 1.
<T7SIA5>-LGART = 1.
<T7SIA5>-ESRPZ = 1.
<T7SIA5>-PAYDT = 1.
ENDLOOP.

LOOP AT IT_T7SIA5 INTO WA_T7SIA5.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T7SIA5-BETRG, sy-vline,
WA_T7SIA5-NEWTO, sy-vline,
WA_T7SIA5-WAERS, sy-vline,
WA_T7SIA5-UNAME, sy-vline,
WA_T7SIA5-AEDTM, sy-vline,
WA_T7SIA5-FLAG1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T7SIA5 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T7SIA5 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T7SIA5 INTO WA_T7SIA5. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T7SIA5_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
LGART TYPE STRING,
ESRPZ TYPE STRING,
PAYDT TYPE STRING,
BETRG TYPE STRING,
NEWTO TYPE STRING,
WAERS TYPE STRING,
UNAME TYPE STRING,
AEDTM TYPE STRING,
FLAG1 TYPE STRING,END OF T_EKKO_STR. DATA: WA_T7SIA5_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T7SIA5_STR-MANDT sy-vline
WA_T7SIA5_STR-PERNR sy-vline
WA_T7SIA5_STR-LGART sy-vline
WA_T7SIA5_STR-ESRPZ sy-vline
WA_T7SIA5_STR-PAYDT sy-vline
WA_T7SIA5_STR-BETRG sy-vline
WA_T7SIA5_STR-NEWTO sy-vline
WA_T7SIA5_STR-WAERS sy-vline
WA_T7SIA5_STR-UNAME sy-vline
WA_T7SIA5_STR-AEDTM sy-vline
WA_T7SIA5_STR-FLAG1 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.