ABAP Select data from SAP table T7SIA2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T7SIA2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T7SIA2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T7SIA2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T7SIA2 TYPE STANDARD TABLE OF T7SIA2,
      WA_T7SIA2 TYPE T7SIA2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T7SIA2> TYPE T7SIA2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T7SIA2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T7SIA2
  INTO TABLE IT_T7SIA2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T7SIA2
*  INTO TABLE @DATA(IT_T7SIA22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T7SIA2 INDEX 1 INTO DATA(WA_T7SIA22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T7SIA2 ASSIGNING <T7SIA2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T7SIA2>-MANDT = 1.
<T7SIA2>-TYEAR = 1.
<T7SIA2>-PERNR = 1.
<T7SIA2>-SECTI = 1.
<T7SIA2>-PAYTX = 1.
ENDLOOP.

LOOP AT IT_T7SIA2 INTO WA_T7SIA2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T7SIA2-GRPID, sy-vline,
WA_T7SIA2-GROSS, sy-vline,
WA_T7SIA2-COSTS, sy-vline,
WA_T7SIA2-TAXIN, sy-vline,
WA_T7SIA2-TAXAB, sy-vline,
WA_T7SIA2-SOCIN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T7SIA2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T7SIA2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T7SIA2 INTO WA_T7SIA2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T7SIA2_STR,
MANDT TYPE STRING,
TYEAR TYPE STRING,
PERNR TYPE STRING,
SECTI TYPE STRING,
PAYTX TYPE STRING,
GRPID TYPE STRING,
GROSS TYPE STRING,
COSTS TYPE STRING,
TAXIN TYPE STRING,
TAXAB TYPE STRING,
SOCIN TYPE STRING,
SELFC TYPE STRING,
PEBEG TYPE STRING,
PEEND TYPE STRING,
AMTYP TYPE STRING,
BEGDT TYPE STRING,
ENDDT TYPE STRING,END OF T_EKKO_STR. DATA: WA_T7SIA2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T7SIA2_STR-MANDT sy-vline
WA_T7SIA2_STR-TYEAR sy-vline
WA_T7SIA2_STR-PERNR sy-vline
WA_T7SIA2_STR-SECTI sy-vline
WA_T7SIA2_STR-PAYTX sy-vline
WA_T7SIA2_STR-GRPID sy-vline
WA_T7SIA2_STR-GROSS sy-vline
WA_T7SIA2_STR-COSTS sy-vline
WA_T7SIA2_STR-TAXIN sy-vline
WA_T7SIA2_STR-TAXAB sy-vline
WA_T7SIA2_STR-SOCIN sy-vline
WA_T7SIA2_STR-SELFC sy-vline
WA_T7SIA2_STR-PEBEG sy-vline
WA_T7SIA2_STR-PEEND sy-vline
WA_T7SIA2_STR-AMTYP sy-vline
WA_T7SIA2_STR-BEGDT sy-vline
WA_T7SIA2_STR-ENDDT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.