ABAP Select data from SAP table T7INREIM_TRNSDT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T7INREIM_TRNSDT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T7INREIM_TRNSDT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T7INREIM_TRNSDT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T7INREIM_TRNSDT TYPE STANDARD TABLE OF T7INREIM_TRNSDT,
      WA_T7INREIM_TRNSDT TYPE T7INREIM_TRNSDT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T7INREIM_TRNSDT> TYPE T7INREIM_TRNSDT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T7INREIM_TRNSDT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T7INREIM_TRNSDT
  INTO TABLE IT_T7INREIM_TRNSDT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T7INREIM_TRNSDT
*  INTO TABLE @DATA(IT_T7INREIM_TRNSDT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T7INREIM_TRNSDT INDEX 1 INTO DATA(WA_T7INREIM_TRNSDT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T7INREIM_TRNSDT ASSIGNING <T7INREIM_TRNSDT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T7INREIM_TRNSDT>-MANDT = 1.
<T7INREIM_TRNSDT>-PERNR = 1.
<T7INREIM_TRNSDT>-REIMB_TYP = 1.
<T7INREIM_TRNSDT>-REFERENCE = 1.
<T7INREIM_TRNSDT>-JBGDT = 1.
ENDLOOP.

LOOP AT IT_T7INREIM_TRNSDT INTO WA_T7INREIM_TRNSDT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T7INREIM_TRNSDT-JENDT, sy-vline,
WA_T7INREIM_TRNSDT-STPNT, sy-vline,
WA_T7INREIM_TRNSDT-DESTN, sy-vline,
WA_T7INREIM_TRNSDT-MTRVL, sy-vline,
WA_T7INREIM_TRNSDT-CTRVL, sy-vline,
WA_T7INREIM_TRNSDT-TKTNO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T7INREIM_TRNSDT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T7INREIM_TRNSDT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T7INREIM_TRNSDT INTO WA_T7INREIM_TRNSDT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T7INREIM_TRNSDT_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
REIMB_TYP TYPE STRING,
REFERENCE TYPE STRING,
JBGDT TYPE STRING,
JENDT TYPE STRING,
STPNT TYPE STRING,
DESTN TYPE STRING,
MTRVL TYPE STRING,
CTRVL TYPE STRING,
TKTNO TYPE STRING,
SLFTR TYPE STRING,
TXEMP TYPE STRING,
MULSEL TYPE STRING,
MINCK TYPE STRING,
FAMSA1 TYPE STRING,
OBJPS1 TYPE STRING,
FAMSA2 TYPE STRING,
OBJPS2 TYPE STRING,
FAMSA3 TYPE STRING,
OBJPS3 TYPE STRING,
FAMSA4 TYPE STRING,
OBJPS4 TYPE STRING,
FAMSA5 TYPE STRING,
OBJPS5 TYPE STRING,
FAMSA6 TYPE STRING,
OBJPS6 TYPE STRING,
FAMSA7 TYPE STRING,
OBJPS7 TYPE STRING,
FAMSA8 TYPE STRING,
OBJPS8 TYPE STRING,
FAMSA9 TYPE STRING,
OBJPS9 TYPE STRING,
FAMSA10 TYPE STRING,
OBJPS10 TYPE STRING,
FAMSA11 TYPE STRING,
OBJPS11 TYPE STRING,
FAMSA12 TYPE STRING,
OBJPS12 TYPE STRING,
FAMSA13 TYPE STRING,
OBJPS13 TYPE STRING,
FAMSA14 TYPE STRING,
OBJPS14 TYPE STRING,
FAMSA15 TYPE STRING,
OBJPS15 TYPE STRING,
FAMSA16 TYPE STRING,
OBJPS16 TYPE STRING,
FAMSA17 TYPE STRING,
OBJPS17 TYPE STRING,
FAMSA18 TYPE STRING,
OBJPS18 TYPE STRING,
FAMSA19 TYPE STRING,
OBJPS19 TYPE STRING,
FAMSA20 TYPE STRING,
OBJPS20 TYPE STRING,
CUS_FLD1 TYPE STRING,
CUS_FLD2 TYPE STRING,
CUS_FLD3 TYPE STRING,
CUS_FLD4 TYPE STRING,
CUS_FLD5 TYPE STRING,
CUS_FLD6 TYPE STRING,
CUS_FLD7 TYPE STRING,
CUS_FLD8 TYPE STRING,
CUS_FLD9 TYPE STRING,
CUS_FLD10 TYPE STRING,END OF T_EKKO_STR. DATA: WA_T7INREIM_TRNSDT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T7INREIM_TRNSDT_STR-MANDT sy-vline
WA_T7INREIM_TRNSDT_STR-PERNR sy-vline
WA_T7INREIM_TRNSDT_STR-REIMB_TYP sy-vline
WA_T7INREIM_TRNSDT_STR-REFERENCE sy-vline
WA_T7INREIM_TRNSDT_STR-JBGDT sy-vline
WA_T7INREIM_TRNSDT_STR-JENDT sy-vline
WA_T7INREIM_TRNSDT_STR-STPNT sy-vline
WA_T7INREIM_TRNSDT_STR-DESTN sy-vline
WA_T7INREIM_TRNSDT_STR-MTRVL sy-vline
WA_T7INREIM_TRNSDT_STR-CTRVL sy-vline
WA_T7INREIM_TRNSDT_STR-TKTNO sy-vline
WA_T7INREIM_TRNSDT_STR-SLFTR sy-vline
WA_T7INREIM_TRNSDT_STR-TXEMP sy-vline
WA_T7INREIM_TRNSDT_STR-MULSEL sy-vline
WA_T7INREIM_TRNSDT_STR-MINCK sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA1 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS1 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA2 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS2 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA3 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS3 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA4 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS4 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA5 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS5 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA6 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS6 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA7 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS7 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA8 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS8 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA9 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS9 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA10 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS10 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA11 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS11 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA12 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS12 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA13 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS13 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA14 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS14 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA15 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS15 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA16 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS16 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA17 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS17 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA18 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS18 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA19 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS19 sy-vline
WA_T7INREIM_TRNSDT_STR-FAMSA20 sy-vline
WA_T7INREIM_TRNSDT_STR-OBJPS20 sy-vline
WA_T7INREIM_TRNSDT_STR-CUS_FLD1 sy-vline
WA_T7INREIM_TRNSDT_STR-CUS_FLD2 sy-vline
WA_T7INREIM_TRNSDT_STR-CUS_FLD3 sy-vline
WA_T7INREIM_TRNSDT_STR-CUS_FLD4 sy-vline
WA_T7INREIM_TRNSDT_STR-CUS_FLD5 sy-vline
WA_T7INREIM_TRNSDT_STR-CUS_FLD6 sy-vline
WA_T7INREIM_TRNSDT_STR-CUS_FLD7 sy-vline
WA_T7INREIM_TRNSDT_STR-CUS_FLD8 sy-vline
WA_T7INREIM_TRNSDT_STR-CUS_FLD9 sy-vline
WA_T7INREIM_TRNSDT_STR-CUS_FLD10 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.