ABAP Select data from SAP table T7INPEX2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T7INPEX2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T7INPEX2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T7INPEX2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T7INPEX2 TYPE STANDARD TABLE OF T7INPEX2,
      WA_T7INPEX2 TYPE T7INPEX2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T7INPEX2> TYPE T7INPEX2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T7INPEX2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T7INPEX2
  INTO TABLE IT_T7INPEX2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T7INPEX2
*  INTO TABLE @DATA(IT_T7INPEX22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T7INPEX2 INDEX 1 INTO DATA(WA_T7INPEX22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T7INPEX2 ASSIGNING <T7INPEX2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T7INPEX2>-MANDT = 1.
<T7INPEX2>-REGUI = 1.
<T7INPEX2>-SEQNM = 1.
<T7INPEX2>-ATIND = 1.
<T7INPEX2>-TDT01 = 1.
ENDLOOP.

LOOP AT IT_T7INPEX2 INTO WA_T7INPEX2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T7INPEX2-TDT02, sy-vline,
WA_T7INPEX2-TDT03, sy-vline,
WA_T7INPEX2-TDT04, sy-vline,
WA_T7INPEX2-TDT05, sy-vline,
WA_T7INPEX2-TDT06, sy-vline,
WA_T7INPEX2-TDT07, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T7INPEX2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T7INPEX2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T7INPEX2 INTO WA_T7INPEX2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T7INPEX2_STR,
MANDT TYPE STRING,
REGUI TYPE STRING,
SEQNM TYPE STRING,
ATIND TYPE STRING,
TDT01 TYPE STRING,
TDT02 TYPE STRING,
TDT03 TYPE STRING,
TDT04 TYPE STRING,
TDT05 TYPE STRING,
TDT06 TYPE STRING,
TDT07 TYPE STRING,
TDT08 TYPE STRING,
TDT09 TYPE STRING,
TDT10 TYPE STRING,
T01T1 TYPE STRING,
T01T2 TYPE STRING,
T01T3 TYPE STRING,
T01T4 TYPE STRING,
T01T5 TYPE STRING,
T03T1 TYPE STRING,
T03T2 TYPE STRING,
T03T3 TYPE STRING,
T03T4 TYPE STRING,
T03T5 TYPE STRING,
T10T1 TYPE STRING,
T10T2 TYPE STRING,
T10T3 TYPE STRING,
T10T4 TYPE STRING,
T10T5 TYPE STRING,
T20T1 TYPE STRING,
T20T2 TYPE STRING,
T20T3 TYPE STRING,
T20T4 TYPE STRING,
T20T5 TYPE STRING,
T40T2 TYPE STRING,
T40T3 TYPE STRING,
T40T4 TYPE STRING,
T40T5 TYPE STRING,
T40T6 TYPE STRING,
T40T7 TYPE STRING,
T40T8 TYPE STRING,
T40T9 TYPE STRING,
T40T0 TYPE STRING,
T41T1 TYPE STRING,
T41T2 TYPE STRING,
T41T3 TYPE STRING,
T41T4 TYPE STRING,
T41T5 TYPE STRING,
T02N1 TYPE STRING,
T02N2 TYPE STRING,
T02N3 TYPE STRING,
T02N4 TYPE STRING,
T02N5 TYPE STRING,
T05N1 TYPE STRING,
T05N2 TYPE STRING,
T05N3 TYPE STRING,
T05N4 TYPE STRING,
T05N5 TYPE STRING,
T10N1 TYPE STRING,
T10N2 TYPE STRING,
T10N3 TYPE STRING,
T10N4 TYPE STRING,
T10N5 TYPE STRING,
T20N1 TYPE STRING,
T20N2 TYPE STRING,
T20N3 TYPE STRING,
T20N4 TYPE STRING,
T20N5 TYPE STRING,
T16N1 TYPE STRING,
T16N2 TYPE STRING,
T16N3 TYPE STRING,
T16N4 TYPE STRING,
T16N5 TYPE STRING,
TKB01 TYPE STRING,
TKB02 TYPE STRING,
TKB03 TYPE STRING,
TKB04 TYPE STRING,
TKB05 TYPE STRING,
TKB06 TYPE STRING,
TKB07 TYPE STRING,
TKB08 TYPE STRING,
TKB09 TYPE STRING,
TKB10 TYPE STRING,
TMT01 TYPE STRING,
TMT02 TYPE STRING,
TMT03 TYPE STRING,
TMT04 TYPE STRING,
TMT05 TYPE STRING,
TAER1 TYPE STRING,
TAER2 TYPE STRING,
TAER3 TYPE STRING,
TAER4 TYPE STRING,
TAER5 TYPE STRING,
TEC01 TYPE STRING,
TEC02 TYPE STRING,
TEC03 TYPE STRING,
TEC04 TYPE STRING,
TEC05 TYPE STRING,
T04T1 TYPE STRING,
T04T2 TYPE STRING,
T04T3 TYPE STRING,
T04T4 TYPE STRING,
T04T5 TYPE STRING,
T80T1 TYPE STRING,
T80T2 TYPE STRING,
T80T3 TYPE STRING,
T80T4 TYPE STRING,
T80T5 TYPE STRING,
T200T1 TYPE STRING,
T200T2 TYPE STRING,
T200T3 TYPE STRING,
T500T1 TYPE STRING,
T500T2 TYPE STRING,
T1000T1 TYPE STRING,END OF T_EKKO_STR. DATA: WA_T7INPEX2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T7INPEX2_STR-MANDT sy-vline
WA_T7INPEX2_STR-REGUI sy-vline
WA_T7INPEX2_STR-SEQNM sy-vline
WA_T7INPEX2_STR-ATIND sy-vline
WA_T7INPEX2_STR-TDT01 sy-vline
WA_T7INPEX2_STR-TDT02 sy-vline
WA_T7INPEX2_STR-TDT03 sy-vline
WA_T7INPEX2_STR-TDT04 sy-vline
WA_T7INPEX2_STR-TDT05 sy-vline
WA_T7INPEX2_STR-TDT06 sy-vline
WA_T7INPEX2_STR-TDT07 sy-vline
WA_T7INPEX2_STR-TDT08 sy-vline
WA_T7INPEX2_STR-TDT09 sy-vline
WA_T7INPEX2_STR-TDT10 sy-vline
WA_T7INPEX2_STR-T01T1 sy-vline
WA_T7INPEX2_STR-T01T2 sy-vline
WA_T7INPEX2_STR-T01T3 sy-vline
WA_T7INPEX2_STR-T01T4 sy-vline
WA_T7INPEX2_STR-T01T5 sy-vline
WA_T7INPEX2_STR-T03T1 sy-vline
WA_T7INPEX2_STR-T03T2 sy-vline
WA_T7INPEX2_STR-T03T3 sy-vline
WA_T7INPEX2_STR-T03T4 sy-vline
WA_T7INPEX2_STR-T03T5 sy-vline
WA_T7INPEX2_STR-T10T1 sy-vline
WA_T7INPEX2_STR-T10T2 sy-vline
WA_T7INPEX2_STR-T10T3 sy-vline
WA_T7INPEX2_STR-T10T4 sy-vline
WA_T7INPEX2_STR-T10T5 sy-vline
WA_T7INPEX2_STR-T20T1 sy-vline
WA_T7INPEX2_STR-T20T2 sy-vline
WA_T7INPEX2_STR-T20T3 sy-vline
WA_T7INPEX2_STR-T20T4 sy-vline
WA_T7INPEX2_STR-T20T5 sy-vline
WA_T7INPEX2_STR-T40T2 sy-vline
WA_T7INPEX2_STR-T40T3 sy-vline
WA_T7INPEX2_STR-T40T4 sy-vline
WA_T7INPEX2_STR-T40T5 sy-vline
WA_T7INPEX2_STR-T40T6 sy-vline
WA_T7INPEX2_STR-T40T7 sy-vline
WA_T7INPEX2_STR-T40T8 sy-vline
WA_T7INPEX2_STR-T40T9 sy-vline
WA_T7INPEX2_STR-T40T0 sy-vline
WA_T7INPEX2_STR-T41T1 sy-vline
WA_T7INPEX2_STR-T41T2 sy-vline
WA_T7INPEX2_STR-T41T3 sy-vline
WA_T7INPEX2_STR-T41T4 sy-vline
WA_T7INPEX2_STR-T41T5 sy-vline
WA_T7INPEX2_STR-T02N1 sy-vline
WA_T7INPEX2_STR-T02N2 sy-vline
WA_T7INPEX2_STR-T02N3 sy-vline
WA_T7INPEX2_STR-T02N4 sy-vline
WA_T7INPEX2_STR-T02N5 sy-vline
WA_T7INPEX2_STR-T05N1 sy-vline
WA_T7INPEX2_STR-T05N2 sy-vline
WA_T7INPEX2_STR-T05N3 sy-vline
WA_T7INPEX2_STR-T05N4 sy-vline
WA_T7INPEX2_STR-T05N5 sy-vline
WA_T7INPEX2_STR-T10N1 sy-vline
WA_T7INPEX2_STR-T10N2 sy-vline
WA_T7INPEX2_STR-T10N3 sy-vline
WA_T7INPEX2_STR-T10N4 sy-vline
WA_T7INPEX2_STR-T10N5 sy-vline
WA_T7INPEX2_STR-T20N1 sy-vline
WA_T7INPEX2_STR-T20N2 sy-vline
WA_T7INPEX2_STR-T20N3 sy-vline
WA_T7INPEX2_STR-T20N4 sy-vline
WA_T7INPEX2_STR-T20N5 sy-vline
WA_T7INPEX2_STR-T16N1 sy-vline
WA_T7INPEX2_STR-T16N2 sy-vline
WA_T7INPEX2_STR-T16N3 sy-vline
WA_T7INPEX2_STR-T16N4 sy-vline
WA_T7INPEX2_STR-T16N5 sy-vline
WA_T7INPEX2_STR-TKB01 sy-vline
WA_T7INPEX2_STR-TKB02 sy-vline
WA_T7INPEX2_STR-TKB03 sy-vline
WA_T7INPEX2_STR-TKB04 sy-vline
WA_T7INPEX2_STR-TKB05 sy-vline
WA_T7INPEX2_STR-TKB06 sy-vline
WA_T7INPEX2_STR-TKB07 sy-vline
WA_T7INPEX2_STR-TKB08 sy-vline
WA_T7INPEX2_STR-TKB09 sy-vline
WA_T7INPEX2_STR-TKB10 sy-vline
WA_T7INPEX2_STR-TMT01 sy-vline
WA_T7INPEX2_STR-TMT02 sy-vline
WA_T7INPEX2_STR-TMT03 sy-vline
WA_T7INPEX2_STR-TMT04 sy-vline
WA_T7INPEX2_STR-TMT05 sy-vline
WA_T7INPEX2_STR-TAER1 sy-vline
WA_T7INPEX2_STR-TAER2 sy-vline
WA_T7INPEX2_STR-TAER3 sy-vline
WA_T7INPEX2_STR-TAER4 sy-vline
WA_T7INPEX2_STR-TAER5 sy-vline
WA_T7INPEX2_STR-TEC01 sy-vline
WA_T7INPEX2_STR-TEC02 sy-vline
WA_T7INPEX2_STR-TEC03 sy-vline
WA_T7INPEX2_STR-TEC04 sy-vline
WA_T7INPEX2_STR-TEC05 sy-vline
WA_T7INPEX2_STR-T04T1 sy-vline
WA_T7INPEX2_STR-T04T2 sy-vline
WA_T7INPEX2_STR-T04T3 sy-vline
WA_T7INPEX2_STR-T04T4 sy-vline
WA_T7INPEX2_STR-T04T5 sy-vline
WA_T7INPEX2_STR-T80T1 sy-vline
WA_T7INPEX2_STR-T80T2 sy-vline
WA_T7INPEX2_STR-T80T3 sy-vline
WA_T7INPEX2_STR-T80T4 sy-vline
WA_T7INPEX2_STR-T80T5 sy-vline
WA_T7INPEX2_STR-T200T1 sy-vline
WA_T7INPEX2_STR-T200T2 sy-vline
WA_T7INPEX2_STR-T200T3 sy-vline
WA_T7INPEX2_STR-T500T1 sy-vline
WA_T7INPEX2_STR-T500T2 sy-vline
WA_T7INPEX2_STR-T1000T1 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.