ABAP Select data from SAP table T7FIIR_S_REPORTS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T7FIIR_S_REPORTS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T7FIIR_S_REPORTS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T7FIIR_S_REPORTS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T7FIIR_S_REPORTS TYPE STANDARD TABLE OF T7FIIR_S_REPORTS,
      WA_T7FIIR_S_REPORTS TYPE T7FIIR_S_REPORTS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T7FIIR_S_REPORTS> TYPE T7FIIR_S_REPORTS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T7FIIR_S_REPORTS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T7FIIR_S_REPORTS
  INTO TABLE IT_T7FIIR_S_REPORTS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T7FIIR_S_REPORTS
*  INTO TABLE @DATA(IT_T7FIIR_S_REPORTS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T7FIIR_S_REPORTS INDEX 1 INTO DATA(WA_T7FIIR_S_REPORTS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T7FIIR_S_REPORTS ASSIGNING <T7FIIR_S_REPORTS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T7FIIR_S_REPORTS>-MANDT = 1.
<T7FIIR_S_REPORTS>-GUID = 1.
<T7FIIR_S_REPORTS>-RECORD_TYPE = 1.
<T7FIIR_S_REPORTS>-IPRUN = 1.
<T7FIIR_S_REPORTS>-FPRUN = 1.
ENDLOOP.

LOOP AT IT_T7FIIR_S_REPORTS INTO WA_T7FIIR_S_REPORTS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T7FIIR_S_REPORTS-DELIVERY_ID, sy-vline,
WA_T7FIIR_S_REPORTS-REPORT_ID, sy-vline,
WA_T7FIIR_S_REPORTS-PERNR, sy-vline,
WA_T7FIIR_S_REPORTS-TXRNO, sy-vline,
WA_T7FIIR_S_REPORTS-IR_REPORT_ID, sy-vline,
WA_T7FIIR_S_REPORTS-STATUS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T7FIIR_S_REPORTS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T7FIIR_S_REPORTS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T7FIIR_S_REPORTS INTO WA_T7FIIR_S_REPORTS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit P44K1, internal->external for field IPRUN CALL FUNCTION 'CONVERSION_EXIT_P44K1_OUTPUT' EXPORTING input = WA_T7FIIR_S_REPORTS-IPRUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T7FIIR_S_REPORTS-IPRUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit P44K1, internal->external for field FPRUN CALL FUNCTION 'CONVERSION_EXIT_P44K1_OUTPUT' EXPORTING input = WA_T7FIIR_S_REPORTS-FPRUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T7FIIR_S_REPORTS-FPRUN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T7FIIR_S_REPORTS_STR,
MANDT TYPE STRING,
GUID TYPE STRING,
RECORD_TYPE TYPE STRING,
IPRUN TYPE STRING,
FPRUN TYPE STRING,
DELIVERY_ID TYPE STRING,
REPORT_ID TYPE STRING,
PERNR TYPE STRING,
TXRNO TYPE STRING,
IR_REPORT_ID TYPE STRING,
STATUS TYPE STRING,
REPORTED_PAYDAY TYPE STRING,
REPORTED_BEGDA TYPE STRING,
REPORTED_ENDDA TYPE STRING,
MANUAL_ADJUST TYPE STRING,
XSD_VERSION TYPE STRING,
VERSION TYPE STRING,
CREATE_DATE TYPE STRING,
CREATE_TIME TYPE STRING,
CREATE_UNAME TYPE STRING,
SEQNR TYPE STRING,
XML TYPE STRING,
LOG TYPE STRING,
FLAGS TYPE STRING,
VALID TYPE STRING,
GENERATED_VERSION TYPE STRING,END OF T_EKKO_STR. DATA: WA_T7FIIR_S_REPORTS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T7FIIR_S_REPORTS_STR-MANDT sy-vline
WA_T7FIIR_S_REPORTS_STR-GUID sy-vline
WA_T7FIIR_S_REPORTS_STR-RECORD_TYPE sy-vline
WA_T7FIIR_S_REPORTS_STR-IPRUN sy-vline
WA_T7FIIR_S_REPORTS_STR-FPRUN sy-vline
WA_T7FIIR_S_REPORTS_STR-DELIVERY_ID sy-vline
WA_T7FIIR_S_REPORTS_STR-REPORT_ID sy-vline
WA_T7FIIR_S_REPORTS_STR-PERNR sy-vline
WA_T7FIIR_S_REPORTS_STR-TXRNO sy-vline
WA_T7FIIR_S_REPORTS_STR-IR_REPORT_ID sy-vline
WA_T7FIIR_S_REPORTS_STR-STATUS sy-vline
WA_T7FIIR_S_REPORTS_STR-REPORTED_PAYDAY sy-vline
WA_T7FIIR_S_REPORTS_STR-REPORTED_BEGDA sy-vline
WA_T7FIIR_S_REPORTS_STR-REPORTED_ENDDA sy-vline
WA_T7FIIR_S_REPORTS_STR-MANUAL_ADJUST sy-vline
WA_T7FIIR_S_REPORTS_STR-XSD_VERSION sy-vline
WA_T7FIIR_S_REPORTS_STR-VERSION sy-vline
WA_T7FIIR_S_REPORTS_STR-CREATE_DATE sy-vline
WA_T7FIIR_S_REPORTS_STR-CREATE_TIME sy-vline
WA_T7FIIR_S_REPORTS_STR-CREATE_UNAME sy-vline
WA_T7FIIR_S_REPORTS_STR-SEQNR sy-vline
WA_T7FIIR_S_REPORTS_STR-XML sy-vline
WA_T7FIIR_S_REPORTS_STR-LOG sy-vline
WA_T7FIIR_S_REPORTS_STR-FLAGS sy-vline
WA_T7FIIR_S_REPORTS_STR-VALID sy-vline
WA_T7FIIR_S_REPORTS_STR-GENERATED_VERSION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.