ABAP Select data from SAP table T7FIIR_S_LOG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T7FIIR_S_LOG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T7FIIR_S_LOG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T7FIIR_S_LOG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T7FIIR_S_LOG TYPE STANDARD TABLE OF T7FIIR_S_LOG,
      WA_T7FIIR_S_LOG TYPE T7FIIR_S_LOG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T7FIIR_S_LOG> TYPE T7FIIR_S_LOG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T7FIIR_S_LOG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T7FIIR_S_LOG
  INTO TABLE IT_T7FIIR_S_LOG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T7FIIR_S_LOG
*  INTO TABLE @DATA(IT_T7FIIR_S_LOG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T7FIIR_S_LOG INDEX 1 INTO DATA(WA_T7FIIR_S_LOG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T7FIIR_S_LOG ASSIGNING <T7FIIR_S_LOG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T7FIIR_S_LOG>-MANDT = 1.
<T7FIIR_S_LOG>-GUID = 1.
<T7FIIR_S_LOG>-LVL = 1.
<T7FIIR_S_LOG>-TYPE = 1.
<T7FIIR_S_LOG>-GROUPING = 1.
ENDLOOP.

LOOP AT IT_T7FIIR_S_LOG INTO WA_T7FIIR_S_LOG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T7FIIR_S_LOG-CODE, sy-vline,
WA_T7FIIR_S_LOG-PERNR, sy-vline,
WA_T7FIIR_S_LOG-IPRUN, sy-vline,
WA_T7FIIR_S_LOG-FPRUN, sy-vline,
WA_T7FIIR_S_LOG-DELIVERY_ID, sy-vline,
WA_T7FIIR_S_LOG-REPORT_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T7FIIR_S_LOG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T7FIIR_S_LOG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T7FIIR_S_LOG INTO WA_T7FIIR_S_LOG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit P44K1, internal->external for field IPRUN CALL FUNCTION 'CONVERSION_EXIT_P44K1_OUTPUT' EXPORTING input = WA_T7FIIR_S_LOG-IPRUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T7FIIR_S_LOG-IPRUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit P44K1, internal->external for field FPRUN CALL FUNCTION 'CONVERSION_EXIT_P44K1_OUTPUT' EXPORTING input = WA_T7FIIR_S_LOG-FPRUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T7FIIR_S_LOG-FPRUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit P44K2, internal->external for field TIMESTAMP CALL FUNCTION 'CONVERSION_EXIT_P44K2_OUTPUT' EXPORTING input = WA_T7FIIR_S_LOG-TIMESTAMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T7FIIR_S_LOG-TIMESTAMP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T7FIIR_S_LOG_STR,
MANDT TYPE STRING,
GUID TYPE STRING,
LVL TYPE STRING,
TYPE TYPE STRING,
GROUPING TYPE STRING,
CODE TYPE STRING,
PERNR TYPE STRING,
IPRUN TYPE STRING,
FPRUN TYPE STRING,
DELIVERY_ID TYPE STRING,
REPORT_ID TYPE STRING,
TEXT TYPE STRING,
DETAIL TYPE STRING,
MSGNR TYPE STRING,
VAR1 TYPE STRING,
VAR2 TYPE STRING,
VAR3 TYPE STRING,
VAR4 TYPE STRING,
ELEMENT TYPE STRING,
XPATH TYPE STRING,
TIMESTAMP TYPE STRING,
UNAME TYPE STRING,
IPRUN_DELIVERY_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_T7FIIR_S_LOG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T7FIIR_S_LOG_STR-MANDT sy-vline
WA_T7FIIR_S_LOG_STR-GUID sy-vline
WA_T7FIIR_S_LOG_STR-LVL sy-vline
WA_T7FIIR_S_LOG_STR-TYPE sy-vline
WA_T7FIIR_S_LOG_STR-GROUPING sy-vline
WA_T7FIIR_S_LOG_STR-CODE sy-vline
WA_T7FIIR_S_LOG_STR-PERNR sy-vline
WA_T7FIIR_S_LOG_STR-IPRUN sy-vline
WA_T7FIIR_S_LOG_STR-FPRUN sy-vline
WA_T7FIIR_S_LOG_STR-DELIVERY_ID sy-vline
WA_T7FIIR_S_LOG_STR-REPORT_ID sy-vline
WA_T7FIIR_S_LOG_STR-TEXT sy-vline
WA_T7FIIR_S_LOG_STR-DETAIL sy-vline
WA_T7FIIR_S_LOG_STR-MSGNR sy-vline
WA_T7FIIR_S_LOG_STR-VAR1 sy-vline
WA_T7FIIR_S_LOG_STR-VAR2 sy-vline
WA_T7FIIR_S_LOG_STR-VAR3 sy-vline
WA_T7FIIR_S_LOG_STR-VAR4 sy-vline
WA_T7FIIR_S_LOG_STR-ELEMENT sy-vline
WA_T7FIIR_S_LOG_STR-XPATH sy-vline
WA_T7FIIR_S_LOG_STR-TIMESTAMP sy-vline
WA_T7FIIR_S_LOG_STR-UNAME sy-vline
WA_T7FIIR_S_LOG_STR-IPRUN_DELIVERY_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.