ABAP Select data from SAP table T7EHS00_RESQINFO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T7EHS00_RESQINFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T7EHS00_RESQINFO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T7EHS00_RESQINFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T7EHS00_RESQINFO TYPE STANDARD TABLE OF T7EHS00_RESQINFO,
      WA_T7EHS00_RESQINFO TYPE T7EHS00_RESQINFO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T7EHS00_RESQINFO> TYPE T7EHS00_RESQINFO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T7EHS00_RESQINFO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T7EHS00_RESQINFO
  INTO TABLE IT_T7EHS00_RESQINFO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T7EHS00_RESQINFO
*  INTO TABLE @DATA(IT_T7EHS00_RESQINFO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T7EHS00_RESQINFO INDEX 1 INTO DATA(WA_T7EHS00_RESQINFO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T7EHS00_RESQINFO ASSIGNING <T7EHS00_RESQINFO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T7EHS00_RESQINFO>-MANDT = 1.
<T7EHS00_RESQINFO>-TYPE = 1.
<T7EHS00_RESQINFO>-CONCATKEY = 1.
<T7EHS00_RESQINFO>-CREATE_DATE = 1.
<T7EHS00_RESQINFO>-QUEST_SERV_ID = 1.
ENDLOOP.

LOOP AT IT_T7EHS00_RESQINFO INTO WA_T7EHS00_RESQINFO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T7EHS00_RESQINFO-QUEST_TYPE, sy-vline,
WA_T7EHS00_RESQINFO-HEADER, sy-vline,
WA_T7EHS00_RESQINFO-FOOTER, sy-vline,
WA_T7EHS00_RESQINFO-IDENTIFICATION, sy-vline,
WA_T7EHS00_RESQINFO-YES_NAME, sy-vline,
WA_T7EHS00_RESQINFO-NO_NAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T7EHS00_RESQINFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T7EHS00_RESQINFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T7EHS00_RESQINFO INTO WA_T7EHS00_RESQINFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T7EHS00_RESQINFO_STR,
MANDT TYPE STRING,
TYPE TYPE STRING,
CONCATKEY TYPE STRING,
CREATE_DATE TYPE STRING,
QUEST_SERV_ID TYPE STRING,
QUEST_TYPE TYPE STRING,
HEADER TYPE STRING,
FOOTER TYPE STRING,
IDENTIFICATION TYPE STRING,
YES_NAME TYPE STRING,
NO_NAME TYPE STRING,
NOREL_NAME TYPE STRING,
PAGE_NAME TYPE STRING,
TEXTFIELD01 TYPE STRING,
TEXTFIELD02 TYPE STRING,
TEXTFIELD03 TYPE STRING,
TEXTFIELD04 TYPE STRING,
TEXTFIELD05 TYPE STRING,
TEXTFIELD06 TYPE STRING,
TEXTFIELD07 TYPE STRING,
TEXTFIELD08 TYPE STRING,
TEXTFIELD09 TYPE STRING,
TEXTFIELD10 TYPE STRING,
TEXTFIELD11 TYPE STRING,
TEXTFIELD12 TYPE STRING,
SEC_HEAD_FLAG TYPE STRING,
TEXTVAR01 TYPE STRING,
TEXTVAR02 TYPE STRING,
TEXTVAR03 TYPE STRING,
TEXTVAR04 TYPE STRING,
TEXTVAR05 TYPE STRING,
TEXTVAR06 TYPE STRING,
TEXTVAR07 TYPE STRING,
TEXTVAR08 TYPE STRING,
TEXTVAR09 TYPE STRING,
TEXTVAR10 TYPE STRING,
TEXTVAR11 TYPE STRING,
TEXTVAR12 TYPE STRING,
MAINTAIN TYPE STRING,END OF T_EKKO_STR. DATA: WA_T7EHS00_RESQINFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T7EHS00_RESQINFO_STR-MANDT sy-vline
WA_T7EHS00_RESQINFO_STR-TYPE sy-vline
WA_T7EHS00_RESQINFO_STR-CONCATKEY sy-vline
WA_T7EHS00_RESQINFO_STR-CREATE_DATE sy-vline
WA_T7EHS00_RESQINFO_STR-QUEST_SERV_ID sy-vline
WA_T7EHS00_RESQINFO_STR-QUEST_TYPE sy-vline
WA_T7EHS00_RESQINFO_STR-HEADER sy-vline
WA_T7EHS00_RESQINFO_STR-FOOTER sy-vline
WA_T7EHS00_RESQINFO_STR-IDENTIFICATION sy-vline
WA_T7EHS00_RESQINFO_STR-YES_NAME sy-vline
WA_T7EHS00_RESQINFO_STR-NO_NAME sy-vline
WA_T7EHS00_RESQINFO_STR-NOREL_NAME sy-vline
WA_T7EHS00_RESQINFO_STR-PAGE_NAME sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD01 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD02 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD03 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD04 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD05 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD06 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD07 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD08 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD09 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD10 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD11 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTFIELD12 sy-vline
WA_T7EHS00_RESQINFO_STR-SEC_HEAD_FLAG sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR01 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR02 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR03 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR04 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR05 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR06 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR07 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR08 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR09 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR10 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR11 sy-vline
WA_T7EHS00_RESQINFO_STR-TEXTVAR12 sy-vline
WA_T7EHS00_RESQINFO_STR-MAINTAIN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.