ABAP Select data from SAP table T77OMFRAM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T77OMFRAM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T77OMFRAM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T77OMFRAM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T77OMFRAM TYPE STANDARD TABLE OF T77OMFRAM,
      WA_T77OMFRAM TYPE T77OMFRAM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T77OMFRAM> TYPE T77OMFRAM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T77OMFRAM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T77OMFRAM
  INTO TABLE IT_T77OMFRAM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T77OMFRAM
*  INTO TABLE @DATA(IT_T77OMFRAM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T77OMFRAM INDEX 1 INTO DATA(WA_T77OMFRAM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T77OMFRAM ASSIGNING <T77OMFRAM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T77OMFRAM>-SCENARIO = 1.
<T77OMFRAM>-FRIEND = 1.
<T77OMFRAM>-OBJMSCEN = 1.
<T77OMFRAM>-DISP_TCODE = 1.
<T77OMFRAM>-CHNG_TCODE = 1.
ENDLOOP.

LOOP AT IT_T77OMFRAM INTO WA_T77OMFRAM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T77OMFRAM-CREA_TCODE, sy-vline,
WA_T77OMFRAM-CHECKTCODE, sy-vline,
WA_T77OMFRAM-TIMEDEP, sy-vline,
WA_T77OMFRAM-NOUNDOREDO, sy-vline,
WA_T77OMFRAM-STATUS_OBJ, sy-vline,
WA_T77OMFRAM-TIME_OBJ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T77OMFRAM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T77OMFRAM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T77OMFRAM INTO WA_T77OMFRAM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T77OMFRAM_STR,
SCENARIO TYPE STRING,
FRIEND TYPE STRING,
OBJMSCEN TYPE STRING,
DISP_TCODE TYPE STRING,
CHNG_TCODE TYPE STRING,
CREA_TCODE TYPE STRING,
CHECKTCODE TYPE STRING,
TIMEDEP TYPE STRING,
NOUNDOREDO TYPE STRING,
STATUS_OBJ TYPE STRING,
TIME_OBJ TYPE STRING,
INITWORKPL TYPE STRING,
INITOBJMAN TYPE STRING,
PLVAR TYPE STRING,
SELDATE TYPE STRING,
MAXUNSAVE TYPE STRING,
UNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_T77OMFRAM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T77OMFRAM_STR-SCENARIO sy-vline
WA_T77OMFRAM_STR-FRIEND sy-vline
WA_T77OMFRAM_STR-OBJMSCEN sy-vline
WA_T77OMFRAM_STR-DISP_TCODE sy-vline
WA_T77OMFRAM_STR-CHNG_TCODE sy-vline
WA_T77OMFRAM_STR-CREA_TCODE sy-vline
WA_T77OMFRAM_STR-CHECKTCODE sy-vline
WA_T77OMFRAM_STR-TIMEDEP sy-vline
WA_T77OMFRAM_STR-NOUNDOREDO sy-vline
WA_T77OMFRAM_STR-STATUS_OBJ sy-vline
WA_T77OMFRAM_STR-TIME_OBJ sy-vline
WA_T77OMFRAM_STR-INITWORKPL sy-vline
WA_T77OMFRAM_STR-INITOBJMAN sy-vline
WA_T77OMFRAM_STR-PLVAR sy-vline
WA_T77OMFRAM_STR-SELDATE sy-vline
WA_T77OMFRAM_STR-MAXUNSAVE sy-vline
WA_T77OMFRAM_STR-UNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.