ABAP Select data from SAP table T72P0 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T72P0 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T72P0. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T72P0 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T72P0 TYPE STANDARD TABLE OF T72P0,
      WA_T72P0 TYPE T72P0,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T72P0> TYPE T72P0.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T72P0.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T72P0
  INTO TABLE IT_T72P0.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T72P0
*  INTO TABLE @DATA(IT_T72P02).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T72P0 INDEX 1 INTO DATA(WA_T72P02).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T72P0 ASSIGNING <T72P0>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T72P0>-MANDT = 1.
<T72P0>-MOLGA = 1.
<T72P0>-APPLI = 1.
<T72P0>-VALTY = 1.
<T72P0>-KASSE = 1.
ENDLOOP.

LOOP AT IT_T72P0 INTO WA_T72P0.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T72P0-ENDDA, sy-vline,
WA_T72P0-BEGDA, sy-vline,
WA_T72P0-LGART, sy-vline,
WA_T72P0-PYTAB, sy-vline,
WA_T72P0-PYFLD, sy-vline,
WA_T72P0-ACCTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T72P0 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T72P0 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T72P0 INTO WA_T72P0. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T72P0_STR,
MANDT TYPE STRING,
MOLGA TYPE STRING,
APPLI TYPE STRING,
VALTY TYPE STRING,
KASSE TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
LGART TYPE STRING,
PYTAB TYPE STRING,
PYFLD TYPE STRING,
ACCTY TYPE STRING,
LATYP TYPE STRING,
NOCUR TYPE STRING,
PPLAN TYPE STRING,
VTYBD TYPE STRING,
VTYVD TYPE STRING,END OF T_EKKO_STR. DATA: WA_T72P0_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T72P0_STR-MANDT sy-vline
WA_T72P0_STR-MOLGA sy-vline
WA_T72P0_STR-APPLI sy-vline
WA_T72P0_STR-VALTY sy-vline
WA_T72P0_STR-KASSE sy-vline
WA_T72P0_STR-ENDDA sy-vline
WA_T72P0_STR-BEGDA sy-vline
WA_T72P0_STR-LGART sy-vline
WA_T72P0_STR-PYTAB sy-vline
WA_T72P0_STR-PYFLD sy-vline
WA_T72P0_STR-ACCTY sy-vline
WA_T72P0_STR-LATYP sy-vline
WA_T72P0_STR-NOCUR sy-vline
WA_T72P0_STR-PPLAN sy-vline
WA_T72P0_STR-VTYBD sy-vline
WA_T72P0_STR-VTYVD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.