ABAP Select data from SAP table T5TREG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T5TREG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T5TREG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T5TREG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T5TREG TYPE STANDARD TABLE OF T5TREG,
      WA_T5TREG TYPE T5TREG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T5TREG> TYPE T5TREG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T5TREG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T5TREG
  INTO TABLE IT_T5TREG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T5TREG
*  INTO TABLE @DATA(IT_T5TREG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T5TREG INDEX 1 INTO DATA(WA_T5TREG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T5TREG ASSIGNING <T5TREG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T5TREG>-CLIENT = 1.
<T5TREG>-RELID = 1.
<T5TREG>-SRTFD = 1.
<T5TREG>-SRTF2 = 1.
<T5TREG>-HISTO = 1.
ENDLOOP.

LOOP AT IT_T5TREG INTO WA_T5TREG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T5TREG-ERROR, sy-vline,
WA_T5TREG-PERNR, sy-vline,
WA_T5TREG-SENDSTAT, sy-vline,
WA_T5TREG-AEDTM, sy-vline,
WA_T5TREG-DATOD, sy-vline,
WA_T5TREG-ELDPPORT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T5TREG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T5TREG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T5TREG INTO WA_T5TREG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T5TREG_STR,
CLIENT TYPE STRING,
RELID TYPE STRING,
SRTFD TYPE STRING,
SRTF2 TYPE STRING,
HISTO TYPE STRING,
ERROR TYPE STRING,
PERNR TYPE STRING,
SENDSTAT TYPE STRING,
AEDTM TYPE STRING,
DATOD TYPE STRING,
ELDPPORT TYPE STRING,
IDSOUB TYPE STRING,
UNAME TYPE STRING,
PNAME TYPE STRING,
VNAME TYPE STRING,
VERSN TYPE STRING,
CLUSTR TYPE STRING,
CLUSTD TYPE STRING,END OF T_EKKO_STR. DATA: WA_T5TREG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T5TREG_STR-CLIENT sy-vline
WA_T5TREG_STR-RELID sy-vline
WA_T5TREG_STR-SRTFD sy-vline
WA_T5TREG_STR-SRTF2 sy-vline
WA_T5TREG_STR-HISTO sy-vline
WA_T5TREG_STR-ERROR sy-vline
WA_T5TREG_STR-PERNR sy-vline
WA_T5TREG_STR-SENDSTAT sy-vline
WA_T5TREG_STR-AEDTM sy-vline
WA_T5TREG_STR-DATOD sy-vline
WA_T5TREG_STR-ELDPPORT sy-vline
WA_T5TREG_STR-IDSOUB sy-vline
WA_T5TREG_STR-UNAME sy-vline
WA_T5TREG_STR-PNAME sy-vline
WA_T5TREG_STR-VNAME sy-vline
WA_T5TREG_STR-VERSN sy-vline
WA_T5TREG_STR-CLUSTR sy-vline
WA_T5TREG_STR-CLUSTD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.