ABAP Select data from SAP table T5D1T into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T5D1T table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T5D1T. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T5D1T table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T5D1T TYPE STANDARD TABLE OF T5D1T,
      WA_T5D1T TYPE T5D1T,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T5D1T> TYPE T5D1T.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T5D1T.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T5D1T
  INTO TABLE IT_T5D1T.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T5D1T
*  INTO TABLE @DATA(IT_T5D1T2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T5D1T INDEX 1 INTO DATA(WA_T5D1T2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T5D1T ASSIGNING <T5D1T>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T5D1T>-MANDT = 1.
<T5D1T>-BMGGR = 1.
<T5D1T>-KPKNZ = 1.
<T5D1T>-ENDDA = 1.
<T5D1T>-BEGDA = 1.
ENDLOOP.

LOOP AT IT_T5D1T INTO WA_T5D1T.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T5D1T-ROUNA, sy-vline,
WA_T5D1T-KONST, sy-vline,
WA_T5D1T-OSTKZ, sy-vline,
WA_T5D1T-ZEINH, sy-vline,
WA_T5D1T-SVTAL, sy-vline,
WA_T5D1T-BMG1L, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T5D1T you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T5D1T TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T5D1T INTO WA_T5D1T. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T5D1T_STR,
MANDT TYPE STRING,
BMGGR TYPE STRING,
KPKNZ TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
ROUNA TYPE STRING,
KONST TYPE STRING,
OSTKZ TYPE STRING,
ZEINH TYPE STRING,
SVTAL TYPE STRING,
BMG1L TYPE STRING,
BMG2L TYPE STRING,
BMG3L TYPE STRING,
BMG4L TYPE STRING,
BMG5L TYPE STRING,END OF T_EKKO_STR. DATA: WA_T5D1T_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T5D1T_STR-MANDT sy-vline
WA_T5D1T_STR-BMGGR sy-vline
WA_T5D1T_STR-KPKNZ sy-vline
WA_T5D1T_STR-ENDDA sy-vline
WA_T5D1T_STR-BEGDA sy-vline
WA_T5D1T_STR-ROUNA sy-vline
WA_T5D1T_STR-KONST sy-vline
WA_T5D1T_STR-OSTKZ sy-vline
WA_T5D1T_STR-ZEINH sy-vline
WA_T5D1T_STR-SVTAL sy-vline
WA_T5D1T_STR-BMG1L sy-vline
WA_T5D1T_STR-BMG2L sy-vline
WA_T5D1T_STR-BMG3L sy-vline
WA_T5D1T_STR-BMG4L sy-vline
WA_T5D1T_STR-BMG5L sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.