ABAP Select data from SAP table T5A74 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T5A74 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T5A74. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T5A74 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T5A74 TYPE STANDARD TABLE OF T5A74,
      WA_T5A74 TYPE T5A74,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T5A74> TYPE T5A74.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T5A74.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T5A74
  INTO TABLE IT_T5A74.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T5A74
*  INTO TABLE @DATA(IT_T5A742).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T5A74 INDEX 1 INTO DATA(WA_T5A742).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T5A74 ASSIGNING <T5A74>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T5A74>-MANDT = 1.
<T5A74>-PERNR = 1.
<T5A74>-REVTY = 1.
<T5A74>-BEGDA = 1.
<T5A74>-ENDDA = 1.
ENDLOOP.

LOOP AT IT_T5A74 INTO WA_T5A74.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T5A74-SEQNR, sy-vline,
WA_T5A74-SETYP, sy-vline,
WA_T5A74-READY, sy-vline,
WA_T5A74-SRTZA, sy-vline,
WA_T5A74-EMETH, sy-vline,
WA_T5A74-LZTYP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T5A74 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T5A74 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T5A74 INTO WA_T5A74. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T5A74_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
REVTY TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
SEQNR TYPE STRING,
SETYP TYPE STRING,
READY TYPE STRING,
SRTZA TYPE STRING,
EMETH TYPE STRING,
LZTYP TYPE STRING,
UNAME TYPE STRING,
DATUM TYPE STRING,
UZEIT TYPE STRING,
PGMID TYPE STRING,
EPRO2 TYPE STRING,
ESVGR TYPE STRING,
EUSVA TYPE STRING,
WOBD0 TYPE STRING,
ZOBD0 TYPE STRING,
EDTNR TYPE STRING,
ESANR TYPE STRING,
ESANI TYPE STRING,
LFVER TYPE STRING,
TFDAT TYPE STRING,
TFTIM TYPE STRING,
FEHL1 TYPE STRING,
FEHL2 TYPE STRING,
FEHL3 TYPE STRING,
FEHL4 TYPE STRING,
FEHL5 TYPE STRING,
ESTAT TYPE STRING,
ANZA0 TYPE STRING,
TTE18 TYPE STRING,
REFNR TYPE STRING,
AUSVL TYPE STRING,
AUSVG TYPE STRING,
ANNNA TYPE STRING,
ANVNA TYPE STRING,
ANTIT TYPE STRING,
GESCH TYPE STRING,
ANADR TYPE STRING,
ANLKZ TYPE STRING,
ANPLZ TYPE STRING,
ANORT TYPE STRING,
ANNUM TYPE STRING,
ANFZA TYPE STRING,
LOHNB TYPE STRING,
AGNUM TYPE STRING,
AGFZA TYPE STRING,
AGDVR TYPE STRING,
AGNAM TYPE STRING,
AGTIT TYPE STRING,
AGADR TYPE STRING,
AGLKZ TYPE STRING,
AGZIP TYPE STRING,
AGORT TYPE STRING,
LBTEL TYPE STRING,
LBFAX TYPE STRING,
LVNUM TYPE STRING,
LVFZA TYPE STRING,
LVDVR TYPE STRING,
ARTE0 TYPE STRING,
WAERS TYPE STRING,
KZ341 TYPE STRING,
KZ344 TYPE STRING,
KZ270 TYPE STRING,
KZ271 TYPE STRING,
INPER TYPE STRING,
REFN0 TYPE STRING,END OF T_EKKO_STR. DATA: WA_T5A74_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T5A74_STR-MANDT sy-vline
WA_T5A74_STR-PERNR sy-vline
WA_T5A74_STR-REVTY sy-vline
WA_T5A74_STR-BEGDA sy-vline
WA_T5A74_STR-ENDDA sy-vline
WA_T5A74_STR-SEQNR sy-vline
WA_T5A74_STR-SETYP sy-vline
WA_T5A74_STR-READY sy-vline
WA_T5A74_STR-SRTZA sy-vline
WA_T5A74_STR-EMETH sy-vline
WA_T5A74_STR-LZTYP sy-vline
WA_T5A74_STR-UNAME sy-vline
WA_T5A74_STR-DATUM sy-vline
WA_T5A74_STR-UZEIT sy-vline
WA_T5A74_STR-PGMID sy-vline
WA_T5A74_STR-EPRO2 sy-vline
WA_T5A74_STR-ESVGR sy-vline
WA_T5A74_STR-EUSVA sy-vline
WA_T5A74_STR-WOBD0 sy-vline
WA_T5A74_STR-ZOBD0 sy-vline
WA_T5A74_STR-EDTNR sy-vline
WA_T5A74_STR-ESANR sy-vline
WA_T5A74_STR-ESANI sy-vline
WA_T5A74_STR-LFVER sy-vline
WA_T5A74_STR-TFDAT sy-vline
WA_T5A74_STR-TFTIM sy-vline
WA_T5A74_STR-FEHL1 sy-vline
WA_T5A74_STR-FEHL2 sy-vline
WA_T5A74_STR-FEHL3 sy-vline
WA_T5A74_STR-FEHL4 sy-vline
WA_T5A74_STR-FEHL5 sy-vline
WA_T5A74_STR-ESTAT sy-vline
WA_T5A74_STR-ANZA0 sy-vline
WA_T5A74_STR-TTE18 sy-vline
WA_T5A74_STR-REFNR sy-vline
WA_T5A74_STR-AUSVL sy-vline
WA_T5A74_STR-AUSVG sy-vline
WA_T5A74_STR-ANNNA sy-vline
WA_T5A74_STR-ANVNA sy-vline
WA_T5A74_STR-ANTIT sy-vline
WA_T5A74_STR-GESCH sy-vline
WA_T5A74_STR-ANADR sy-vline
WA_T5A74_STR-ANLKZ sy-vline
WA_T5A74_STR-ANPLZ sy-vline
WA_T5A74_STR-ANORT sy-vline
WA_T5A74_STR-ANNUM sy-vline
WA_T5A74_STR-ANFZA sy-vline
WA_T5A74_STR-LOHNB sy-vline
WA_T5A74_STR-AGNUM sy-vline
WA_T5A74_STR-AGFZA sy-vline
WA_T5A74_STR-AGDVR sy-vline
WA_T5A74_STR-AGNAM sy-vline
WA_T5A74_STR-AGTIT sy-vline
WA_T5A74_STR-AGADR sy-vline
WA_T5A74_STR-AGLKZ sy-vline
WA_T5A74_STR-AGZIP sy-vline
WA_T5A74_STR-AGORT sy-vline
WA_T5A74_STR-LBTEL sy-vline
WA_T5A74_STR-LBFAX sy-vline
WA_T5A74_STR-LVNUM sy-vline
WA_T5A74_STR-LVFZA sy-vline
WA_T5A74_STR-LVDVR sy-vline
WA_T5A74_STR-ARTE0 sy-vline
WA_T5A74_STR-WAERS sy-vline
WA_T5A74_STR-KZ341 sy-vline
WA_T5A74_STR-KZ344 sy-vline
WA_T5A74_STR-KZ270 sy-vline
WA_T5A74_STR-KZ271 sy-vline
WA_T5A74_STR-INPER sy-vline
WA_T5A74_STR-REFN0 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.