ABAP Select data from SAP table T588J into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T588J table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T588J. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T588J table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T588J TYPE STANDARD TABLE OF T588J,
      WA_T588J TYPE T588J,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T588J> TYPE T588J.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T588J.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T588J
  INTO TABLE IT_T588J.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T588J
*  INTO TABLE @DATA(IT_T588J2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T588J INDEX 1 INTO DATA(WA_T588J2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T588J ASSIGNING <T588J>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T588J>-MANDT = 1.
<T588J>-HDMOD = 1.
<T588J>-LINNO = 1.
<T588J>-COLNO = 1.
<T588J>-SNAME = 1.
ENDLOOP.

LOOP AT IT_T588J INTO WA_T588J.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T588J-LENGT, sy-vline,
WA_T588J-KYWRD, sy-vline,
WA_T588J-FCONV, sy-vline,
WA_T588J-FLDTP, sy-vline,
WA_T588J-INFTY, sy-vline,
WA_T588J-SUBTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T588J you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T588J TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T588J INTO WA_T588J. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T588J_STR,
MANDT TYPE STRING,
HDMOD TYPE STRING,
LINNO TYPE STRING,
COLNO TYPE STRING,
SNAME TYPE STRING,
LENGT TYPE STRING,
KYWRD TYPE STRING,
FCONV TYPE STRING,
FLDTP TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,END OF T_EKKO_STR. DATA: WA_T588J_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T588J_STR-MANDT sy-vline
WA_T588J_STR-HDMOD sy-vline
WA_T588J_STR-LINNO sy-vline
WA_T588J_STR-COLNO sy-vline
WA_T588J_STR-SNAME sy-vline
WA_T588J_STR-LENGT sy-vline
WA_T588J_STR-KYWRD sy-vline
WA_T588J_STR-FCONV sy-vline
WA_T588J_STR-FLDTP sy-vline
WA_T588J_STR-INFTY sy-vline
WA_T588J_STR-SUBTY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.