ABAP Select data from SAP table T352R_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T352R_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T352R_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T352R_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T352R_D TYPE STANDARD TABLE OF T352R_D,
      WA_T352R_D TYPE T352R_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T352R_D> TYPE T352R_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T352R_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T352R_D
  INTO TABLE IT_T352R_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T352R_D
*  INTO TABLE @DATA(IT_T352R_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T352R_D INDEX 1 INTO DATA(WA_T352R_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T352R_D ASSIGNING <T352R_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T352R_D>-MARK = 1.
<T352R_D>-MANDT = 1.
<T352R_D>-IWERK = 1.
<T352R_D>-REVNR = 1.
<T352R_D>-REVBD = 1.
ENDLOOP.

LOOP AT IT_T352R_D INTO WA_T352R_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T352R_D-REVBZ, sy-vline,
WA_T352R_D-REVED, sy-vline,
WA_T352R_D-REVEZ, sy-vline,
WA_T352R_D-REVTX, sy-vline,
WA_T352R_D-REVAB, sy-vline,
WA_T352R_D-PM_OBJTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T352R_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T352R_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T352R_D INTO WA_T352R_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T352R_D-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T352R_D-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_T352R_D-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T352R_D-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPEL CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_T352R_D-PSPEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T352R_D-PSPEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T352R_D-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T352R_D-AUFNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T352R_D_STR,
MARK TYPE STRING,
MANDT TYPE STRING,
IWERK TYPE STRING,
REVNR TYPE STRING,
REVBD TYPE STRING,
REVBZ TYPE STRING,
REVED TYPE STRING,
REVEZ TYPE STRING,
REVTX TYPE STRING,
REVAB TYPE STRING,
PM_OBJTY TYPE STRING,
GEWRK TYPE STRING,
EQUNR TYPE STRING,
TPLNR TYPE STRING,
PSPEL TYPE STRING,
AUFNR TYPE STRING,
AENAM TYPE STRING,
AEDAT TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
OBJNR TYPE STRING,
REVTY TYPE STRING,
OBJID TYPE STRING,
VAPLZ TYPE STRING,
VAWRK TYPE STRING,
EXTAPPL TYPE STRING,
EXTREF TYPE STRING,
NAME1 TYPE STRING,
PLTXT TYPE STRING,
POST1 TYPE STRING,
KTEXT TYPE STRING,
STTXT TYPE STRING,
VATXT TYPE STRING,
EQKTX TYPE STRING,END OF T_EKKO_STR. DATA: WA_T352R_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T352R_D_STR-MARK sy-vline
WA_T352R_D_STR-MANDT sy-vline
WA_T352R_D_STR-IWERK sy-vline
WA_T352R_D_STR-REVNR sy-vline
WA_T352R_D_STR-REVBD sy-vline
WA_T352R_D_STR-REVBZ sy-vline
WA_T352R_D_STR-REVED sy-vline
WA_T352R_D_STR-REVEZ sy-vline
WA_T352R_D_STR-REVTX sy-vline
WA_T352R_D_STR-REVAB sy-vline
WA_T352R_D_STR-PM_OBJTY sy-vline
WA_T352R_D_STR-GEWRK sy-vline
WA_T352R_D_STR-EQUNR sy-vline
WA_T352R_D_STR-TPLNR sy-vline
WA_T352R_D_STR-PSPEL sy-vline
WA_T352R_D_STR-AUFNR sy-vline
WA_T352R_D_STR-AENAM sy-vline
WA_T352R_D_STR-AEDAT sy-vline
WA_T352R_D_STR-ERNAM sy-vline
WA_T352R_D_STR-ERDAT sy-vline
WA_T352R_D_STR-OBJNR sy-vline
WA_T352R_D_STR-REVTY sy-vline
WA_T352R_D_STR-OBJID sy-vline
WA_T352R_D_STR-VAPLZ sy-vline
WA_T352R_D_STR-VAWRK sy-vline
WA_T352R_D_STR-EXTAPPL sy-vline
WA_T352R_D_STR-EXTREF sy-vline
WA_T352R_D_STR-NAME1 sy-vline
WA_T352R_D_STR-PLTXT sy-vline
WA_T352R_D_STR-POST1 sy-vline
WA_T352R_D_STR-KTEXT sy-vline
WA_T352R_D_STR-STTXT sy-vline
WA_T352R_D_STR-VATXT sy-vline
WA_T352R_D_STR-EQKTX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.