ABAP Select data from SAP table T000ATP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T000ATP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T000ATP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T000ATP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T000ATP TYPE STANDARD TABLE OF T000ATP,
      WA_T000ATP TYPE T000ATP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T000ATP> TYPE T000ATP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T000ATP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T000ATP
  INTO TABLE IT_T000ATP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T000ATP
*  INTO TABLE @DATA(IT_T000ATP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T000ATP INDEX 1 INTO DATA(WA_T000ATP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T000ATP ASSIGNING <T000ATP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T000ATP>-MANDT = 1.
<T000ATP>-GRP_WO_GRKOR = 1.
<T000ATP>-GRP_CALL_FUN = 1.
<T000ATP>-GRP_BDC_BACK = 1.
<T000ATP>-MAD_MOVEBACK = 1.
ENDLOOP.

LOOP AT IT_T000ATP INTO WA_T000ATP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T000ATP-BSKRF_OFF_A, sy-vline,
WA_T000ATP-BSKRF_OFF_B, sy-vline,
WA_T000ATP-BSKRF_OFF_PRD, sy-vline,
WA_T000ATP-BSKRF_OFF_BATCH, sy-vline,
WA_T000ATP-BSKRF_OFF_EXPL, sy-vline,
WA_T000ATP-BSKRF_OFF_MIGO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T000ATP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T000ATP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T000ATP INTO WA_T000ATP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T000ATP_STR,
MANDT TYPE STRING,
GRP_WO_GRKOR TYPE STRING,
GRP_CALL_FUN TYPE STRING,
GRP_BDC_BACK TYPE STRING,
MAD_MOVEBACK TYPE STRING,
BSKRF_OFF_A TYPE STRING,
BSKRF_OFF_B TYPE STRING,
BSKRF_OFF_PRD TYPE STRING,
BSKRF_OFF_BATCH TYPE STRING,
BSKRF_OFF_EXPL TYPE STRING,
BSKRF_OFF_MIGO TYPE STRING,
ERP_ACTIME TYPE STRING,
ERP_SCHED_NO_TIMEZONE TYPE STRING,
LIVECACHE_STATUS TYPE STRING,
ERP_CHARG_OFF TYPE STRING,END OF T_EKKO_STR. DATA: WA_T000ATP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T000ATP_STR-MANDT sy-vline
WA_T000ATP_STR-GRP_WO_GRKOR sy-vline
WA_T000ATP_STR-GRP_CALL_FUN sy-vline
WA_T000ATP_STR-GRP_BDC_BACK sy-vline
WA_T000ATP_STR-MAD_MOVEBACK sy-vline
WA_T000ATP_STR-BSKRF_OFF_A sy-vline
WA_T000ATP_STR-BSKRF_OFF_B sy-vline
WA_T000ATP_STR-BSKRF_OFF_PRD sy-vline
WA_T000ATP_STR-BSKRF_OFF_BATCH sy-vline
WA_T000ATP_STR-BSKRF_OFF_EXPL sy-vline
WA_T000ATP_STR-BSKRF_OFF_MIGO sy-vline
WA_T000ATP_STR-ERP_ACTIME sy-vline
WA_T000ATP_STR-ERP_SCHED_NO_TIMEZONE sy-vline
WA_T000ATP_STR-LIVECACHE_STATUS sy-vline
WA_T000ATP_STR-ERP_CHARG_OFF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.