ABAP Select data from SAP table SYBCFG_TFLAGS into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP SYBCFG_TFLAGS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SYBCFG_TFLAGS. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the SYBCFG_TFLAGS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_SYBCFG_TFLAGS TYPE STANDARD TABLE OF SYBCFG_TFLAGS, WA_SYBCFG_TFLAGS TYPE SYBCFG_TFLAGS, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <SYBCFG_TFLAGS> TYPE SYBCFG_TFLAGS. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_SYBCFG_TFLAGS. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM SYBCFG_TFLAGS INTO TABLE IT_SYBCFG_TFLAGS. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM SYBCFG_TFLAGS * INTO TABLE @DATA(IT_SYBCFG_TFLAGS2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_SYBCFG_TFLAGS INDEX 1 INTO DATA(WA_SYBCFG_TFLAGS2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_SYBCFG_TFLAGS ASSIGNING <SYBCFG_TFLAGS>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<SYBCFG_TFLAGS>-SPID = 1.
<SYBCFG_TFLAGS>-CATEGORY = 1.
<SYBCFG_TFLAGS>-NAME = 1.
<SYBCFG_TFLAGS>-CURRENTSETTING = 1.
<SYBCFG_TFLAGS>-DEFAULTSETTING = 1.
ENDLOOP. LOOP AT IT_SYBCFG_TFLAGS INTO WA_SYBCFG_TFLAGS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_SYBCFG_TFLAGS-IS_DEFAULT, sy-vline,
WA_SYBCFG_TFLAGS-SWITCH_NUMBER, sy-vline,
WA_SYBCFG_TFLAGS-SWITCH_SCOPE, sy-vline,
WA_SYBCFG_TFLAGS-RESULT_ICON, sy-vline,
WA_SYBCFG_TFLAGS-DBVERSION_MIN, sy-vline,
WA_SYBCFG_TFLAGS-DBVERSION_MAX, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SYBCFG_TFLAGS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SYBCFG_TFLAGS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SYBCFG_TFLAGS INTO WA_SYBCFG_TFLAGS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SYBCFG_TFLAGS_STR,
SPID TYPE STRING,
CATEGORY TYPE STRING,
NAME TYPE STRING,
CURRENTSETTING TYPE STRING,
DEFAULTSETTING TYPE STRING,
IS_DEFAULT TYPE STRING,
SWITCH_NUMBER TYPE STRING,
SWITCH_SCOPE TYPE STRING,
RESULT_ICON TYPE STRING,
DBVERSION_MIN TYPE STRING,
DBVERSION_MAX TYPE STRING,
PARAM_REQ TYPE STRING,
PARAM_FRB TYPE STRING,
PARAM_OS TYPE STRING,
SORT_ORDER TYPE STRING,END OF T_EKKO_STR. DATA: WA_SYBCFG_TFLAGS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SYBCFG_TFLAGS_STR-SPID sy-vline
WA_SYBCFG_TFLAGS_STR-CATEGORY sy-vline
WA_SYBCFG_TFLAGS_STR-NAME sy-vline
WA_SYBCFG_TFLAGS_STR-CURRENTSETTING sy-vline
WA_SYBCFG_TFLAGS_STR-DEFAULTSETTING sy-vline
WA_SYBCFG_TFLAGS_STR-IS_DEFAULT sy-vline
WA_SYBCFG_TFLAGS_STR-SWITCH_NUMBER sy-vline
WA_SYBCFG_TFLAGS_STR-SWITCH_SCOPE sy-vline
WA_SYBCFG_TFLAGS_STR-RESULT_ICON sy-vline
WA_SYBCFG_TFLAGS_STR-DBVERSION_MIN sy-vline
WA_SYBCFG_TFLAGS_STR-DBVERSION_MAX sy-vline
WA_SYBCFG_TFLAGS_STR-PARAM_REQ sy-vline
WA_SYBCFG_TFLAGS_STR-PARAM_FRB sy-vline
WA_SYBCFG_TFLAGS_STR-PARAM_OS sy-vline
WA_SYBCFG_TFLAGS_STR-SORT_ORDER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.