ABAP Select data from SAP table SYB_XCHG_SYSTIMESPENT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SYB_XCHG_SYSTIMESPENT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SYB_XCHG_SYSTIMESPENT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SYB_XCHG_SYSTIMESPENT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SYB_XCHG_SYSTIMESPENT TYPE STANDARD TABLE OF SYB_XCHG_SYSTIMESPENT,
      WA_SYB_XCHG_SYSTIMESPENT TYPE SYB_XCHG_SYSTIMESPENT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SYB_XCHG_SYSTIMESPENT> TYPE SYB_XCHG_SYSTIMESPENT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SYB_XCHG_SYSTIMESPENT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SYB_XCHG_SYSTIMESPENT
  INTO TABLE IT_SYB_XCHG_SYSTIMESPENT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SYB_XCHG_SYSTIMESPENT
*  INTO TABLE @DATA(IT_SYB_XCHG_SYSTIMESPENT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SYB_XCHG_SYSTIMESPENT INDEX 1 INTO DATA(WA_SYB_XCHG_SYSTIMESPENT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SYB_XCHG_SYSTIMESPENT ASSIGNING <SYB_XCHG_SYSTIMESPENT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SYB_XCHG_SYSTIMESPENT>-COMPONENT = 1.
<SYB_XCHG_SYSTIMESPENT>-INSTANCEID = 1.
<SYB_XCHG_SYSTIMESPENT>-TYPE = 1.
<SYB_XCHG_SYSTIMESPENT>-TYPE_TECHN = 1.
<SYB_XCHG_SYSTIMESPENT>-COMPONENT = 1.
ENDLOOP.

LOOP AT IT_SYB_XCHG_SYSTIMESPENT INTO WA_SYB_XCHG_SYSTIMESPENT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SYB_XCHG_SYSTIMESPENT-COMPONENTID, sy-vline,
WA_SYB_XCHG_SYSTIMESPENT-COMPONENTCLASS, sy-vline,
WA_SYB_XCHG_SYSTIMESPENT-COMPONENTCLASSID, sy-vline,
WA_SYB_XCHG_SYSTIMESPENT-COMPONENTCNT, sy-vline,
WA_SYB_XCHG_SYSTIMESPENT-COMPONENTTIME, sy-vline,
WA_SYB_XCHG_SYSTIMESPENT-AVG_COMPONENTTIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SYB_XCHG_SYSTIMESPENT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SYB_XCHG_SYSTIMESPENT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SYB_XCHG_SYSTIMESPENT INTO WA_SYB_XCHG_SYSTIMESPENT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SYB_XCHG_SYSTIMESPENT_STR,
COMPONENT TYPE STRING,
INSTANCEID TYPE STRING,
TYPE TYPE STRING,
TYPE_TECHN TYPE STRING,
COMPONENT TYPE STRING,
COMPONENTID TYPE STRING,
COMPONENTCLASS TYPE STRING,
COMPONENTCLASSID TYPE STRING,
COMPONENTCNT TYPE STRING,
COMPONENTTIME TYPE STRING,
AVG_COMPONENTTIME TYPE STRING,
SNAPSHOT_TIMESTAMP TYPE STRING,
TIMESTAMP_FROM TYPE STRING,
TIMESTAMP_TO TYPE STRING,
TIME_PERIOD TYPE STRING,
SOURCE_HOSTNAME TYPE STRING,
CAUSEDBY_DESCR TYPE STRING,
TIME_SELECTION TYPE STRING,
FROM_DATE TYPE STRING,
FROM_TIME TYPE STRING,
TO_DATE TYPE STRING,
TO_TIME TYPE STRING,
TIME_FRAME TYPE STRING,
RANGETYPE TYPE STRING,
TIME_ZONE TYPE STRING,
GRANULARITY TYPE STRING,
TIME_RANGE_READONLY TYPE STRING,
TIME_RANGE_HIDDEN TYPE STRING,
TIME_RANGE_DESCR TYPE STRING,
CONFIRM_ENABLED TYPE STRING,
GRANULARITY_ENABLED TYPE STRING,
AGGREGATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_SYB_XCHG_SYSTIMESPENT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-COMPONENT sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-INSTANCEID sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TYPE sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TYPE_TECHN sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-COMPONENT sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-COMPONENTID sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-COMPONENTCLASS sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-COMPONENTCLASSID sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-COMPONENTCNT sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-COMPONENTTIME sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-AVG_COMPONENTTIME sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-SNAPSHOT_TIMESTAMP sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TIMESTAMP_FROM sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TIMESTAMP_TO sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TIME_PERIOD sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-SOURCE_HOSTNAME sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-CAUSEDBY_DESCR sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TIME_SELECTION sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-FROM_DATE sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-FROM_TIME sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TO_DATE sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TO_TIME sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TIME_FRAME sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-RANGETYPE sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TIME_ZONE sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-GRANULARITY sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TIME_RANGE_READONLY sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TIME_RANGE_HIDDEN sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-TIME_RANGE_DESCR sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-CONFIRM_ENABLED sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-GRANULARITY_ENABLED sy-vline
WA_SYB_XCHG_SYSTIMESPENT_STR-AGGREGATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.