ABAP Select data from SAP table SXMB_ADAPTER_FRAMEWORK_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SXMB_ADAPTER_FRAMEWORK_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SXMB_ADAPTER_FRAMEWORK_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SXMB_ADAPTER_FRAMEWORK_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SXMB_ADAPTER_FRAMEWORK_DATA TYPE STANDARD TABLE OF SXMB_ADAPTER_FRAMEWORK_DATA,
      WA_SXMB_ADAPTER_FRAMEWORK_DATA TYPE SXMB_ADAPTER_FRAMEWORK_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SXMB_ADAPTER_FRAMEWORK_DATA> TYPE SXMB_ADAPTER_FRAMEWORK_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SXMB_ADAPTER_FRAMEWORK_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SXMB_ADAPTER_FRAMEWORK_DATA
  INTO TABLE IT_SXMB_ADAPTER_FRAMEWORK_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SXMB_ADAPTER_FRAMEWORK_DATA
*  INTO TABLE @DATA(IT_SXMB_ADAPTER_FRAMEWORK_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SXMB_ADAPTER_FRAMEWORK_DATA INDEX 1 INTO DATA(WA_SXMB_ADAPTER_FRAMEWORK_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SXMB_ADAPTER_FRAMEWORK_DATA ASSIGNING <SXMB_ADAPTER_FRAMEWORK_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SXMB_ADAPTER_FRAMEWORK_DATA>-APPLICATION_COMPONENT = 1.
<SXMB_ADAPTER_FRAMEWORK_DATA>-BUSINESS_MESSAGEX = 1.
<SXMB_ADAPTER_FRAMEWORK_DATA>-CANCELABLEX = 1.
<SXMB_ADAPTER_FRAMEWORK_DATA>-CONNECTION_NAME = 1.
<SXMB_ADAPTER_FRAMEWORK_DATA>-CREDENTIAL = 1.
ENDLOOP.

LOOP AT IT_SXMB_ADAPTER_FRAMEWORK_DATA INTO WA_SXMB_ADAPTER_FRAMEWORK_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SXMB_ADAPTER_FRAMEWORK_DATA-DIRECTION, sy-vline,
WA_SXMB_ADAPTER_FRAMEWORK_DATA-EDITABLEX, sy-vline,
WA_SXMB_ADAPTER_FRAMEWORK_DATA-END_TIME, sy-vline,
WA_SXMB_ADAPTER_FRAMEWORK_DATA-ENDPOINT, sy-vline,
WA_SXMB_ADAPTER_FRAMEWORK_DATA-ERROR_CATEGORY, sy-vline,
WA_SXMB_ADAPTER_FRAMEWORK_DATA-ERROR_CODE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SXMB_ADAPTER_FRAMEWORK_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SXMB_ADAPTER_FRAMEWORK_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SXMB_ADAPTER_FRAMEWORK_DATA INTO WA_SXMB_ADAPTER_FRAMEWORK_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SXMB_ADAPTER_FRAMEWORK_DATA_STR,
APPLICATION_COMPONENT TYPE STRING,
BUSINESS_MESSAGEX TYPE STRING,
CANCELABLEX TYPE STRING,
CONNECTION_NAME TYPE STRING,
CREDENTIAL TYPE STRING,
DIRECTION TYPE STRING,
EDITABLEX TYPE STRING,
END_TIME TYPE STRING,
ENDPOINT TYPE STRING,
ERROR_CATEGORY TYPE STRING,
ERROR_CODE TYPE STRING,
HEADERS TYPE STRING,
INTERFACE TYPE STRING,
NAME TYPE STRING,
NAMESPACE TYPE STRING,
IS_PERSISTENT TYPE STRING,
MESSAGE_ID TYPE STRING,
MESSAGE_KEY TYPE STRING,
MESSAGE_TYPE TYPE STRING,
NODE_ID1 TYPE STRING,
PERSIST_UNTIL TYPE STRING,
PROTOCOL TYPE STRING,
QUALITY_OF_SERVICE TYPE STRING,
RECEIVER_INTERFACE TYPE STRING,
NAME TYPE STRING,
NAMESPACE TYPE STRING,
RECEIVER_NAME TYPE STRING,
RECEIVER_PARTY TYPE STRING,
AGENCY TYPE STRING,
NAME TYPE STRING,
SCHEMA TYPE STRING,
REFERENCE_ID TYPE STRING,
RESTARTABLEX TYPE STRING,
RETRIES TYPE STRING,
RETRY_INTERVAL TYPE STRING,
SCHEDULE_TIME TYPE STRING,
SENDER_INTERFACE TYPE STRING,
NAME TYPE STRING,
NAMESPACE TYPE STRING,
SENDER_NAME TYPE STRING,
SENDER_PARTY TYPE STRING,
AGENCY TYPE STRING,
NAME TYPE STRING,
SCHEMA TYPE STRING,
SEQUENCE_NUMBER TYPE STRING,
SERIALIZATION_CONTEXT TYPE STRING,
SERVICE_DEFINITION TYPE STRING,
SOFTWARE_COMPONENT TYPE STRING,
START_TIME TYPE STRING,
STATUS TYPE STRING,
TIMES_FAILED TYPE STRING,
TRANSPORT TYPE STRING,
VALID_UNTIL TYPE STRING,
VERSION TYPE STRING,
WAS_EDITEDX TYPE STRING,END OF T_EKKO_STR. DATA: WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-APPLICATION_COMPONENT sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-BUSINESS_MESSAGEX sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-CANCELABLEX sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-CONNECTION_NAME sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-CREDENTIAL sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-DIRECTION sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-EDITABLEX sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-END_TIME sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-ENDPOINT sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-ERROR_CATEGORY sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-ERROR_CODE sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-HEADERS sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-INTERFACE sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-NAME sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-NAMESPACE sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-IS_PERSISTENT sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-MESSAGE_ID sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-MESSAGE_KEY sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-MESSAGE_TYPE sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-NODE_ID1 sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-PERSIST_UNTIL sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-PROTOCOL sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-QUALITY_OF_SERVICE sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-RECEIVER_INTERFACE sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-NAME sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-NAMESPACE sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-RECEIVER_NAME sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-RECEIVER_PARTY sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-AGENCY sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-NAME sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-SCHEMA sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-REFERENCE_ID sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-RESTARTABLEX sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-RETRIES sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-RETRY_INTERVAL sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-SCHEDULE_TIME sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-SENDER_INTERFACE sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-NAME sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-NAMESPACE sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-SENDER_NAME sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-SENDER_PARTY sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-AGENCY sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-NAME sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-SCHEMA sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-SEQUENCE_NUMBER sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-SERIALIZATION_CONTEXT sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-SERVICE_DEFINITION sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-SOFTWARE_COMPONENT sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-START_TIME sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-STATUS sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-TIMES_FAILED sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-TRANSPORT sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-VALID_UNTIL sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-VERSION sy-vline
WA_SXMB_ADAPTER_FRAMEWORK_DATA_STR-WAS_EDITEDX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.