ABAP Select data from SAP table SPRXT_ROOT_TYPE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SPRXT_ROOT_TYPE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SPRXT_ROOT_TYPE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SPRXT_ROOT_TYPE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SPRXT_ROOT_TYPE TYPE STANDARD TABLE OF SPRXT_ROOT_TYPE,
      WA_SPRXT_ROOT_TYPE TYPE SPRXT_ROOT_TYPE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SPRXT_ROOT_TYPE> TYPE SPRXT_ROOT_TYPE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SPRXT_ROOT_TYPE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SPRXT_ROOT_TYPE
  INTO TABLE IT_SPRXT_ROOT_TYPE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SPRXT_ROOT_TYPE
*  INTO TABLE @DATA(IT_SPRXT_ROOT_TYPE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SPRXT_ROOT_TYPE INDEX 1 INTO DATA(WA_SPRXT_ROOT_TYPE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SPRXT_ROOT_TYPE ASSIGNING <SPRXT_ROOT_TYPE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SPRXT_ROOT_TYPE>-CONTROLLER = 1.
<SPRXT_ROOT_TYPE>-EL1 = 1.
<SPRXT_ROOT_TYPE>-CONTROLLER = 1.
<SPRXT_ROOT_TYPE>-ELEM1 = 1.
<SPRXT_ROOT_TYPE>-CONTROLLER = 1.
ENDLOOP.

LOOP AT IT_SPRXT_ROOT_TYPE INTO WA_SPRXT_ROOT_TYPE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SPRXT_ROOT_TYPE-ELEM1, sy-vline,
WA_SPRXT_ROOT_TYPE-CONTROLLER, sy-vline,
WA_SPRXT_ROOT_TYPE-ELEMENT1, sy-vline,
WA_SPRXT_ROOT_TYPE-ATT1, sy-vline,
WA_SPRXT_ROOT_TYPE-EL2, sy-vline,
WA_SPRXT_ROOT_TYPE-CONTROLLER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SPRXT_ROOT_TYPE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SPRXT_ROOT_TYPE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SPRXT_ROOT_TYPE INTO WA_SPRXT_ROOT_TYPE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SPRXT_ROOT_TYPE_STR,
CONTROLLER TYPE STRING,
EL1 TYPE STRING,
CONTROLLER TYPE STRING,
ELEM1 TYPE STRING,
CONTROLLER TYPE STRING,
ELEM1 TYPE STRING,
CONTROLLER TYPE STRING,
ELEMENT1 TYPE STRING,
ATT1 TYPE STRING,
EL2 TYPE STRING,
CONTROLLER TYPE STRING,
EL1 TYPE STRING,END OF T_EKKO_STR. DATA: WA_SPRXT_ROOT_TYPE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SPRXT_ROOT_TYPE_STR-CONTROLLER sy-vline
WA_SPRXT_ROOT_TYPE_STR-EL1 sy-vline
WA_SPRXT_ROOT_TYPE_STR-CONTROLLER sy-vline
WA_SPRXT_ROOT_TYPE_STR-ELEM1 sy-vline
WA_SPRXT_ROOT_TYPE_STR-CONTROLLER sy-vline
WA_SPRXT_ROOT_TYPE_STR-ELEM1 sy-vline
WA_SPRXT_ROOT_TYPE_STR-CONTROLLER sy-vline
WA_SPRXT_ROOT_TYPE_STR-ELEMENT1 sy-vline
WA_SPRXT_ROOT_TYPE_STR-ATT1 sy-vline
WA_SPRXT_ROOT_TYPE_STR-EL2 sy-vline
WA_SPRXT_ROOT_TYPE_STR-CONTROLLER sy-vline
WA_SPRXT_ROOT_TYPE_STR-EL1 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.