ABAP Select data from SAP table SPFL1020 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SPFL1020 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SPFL1020. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SPFL1020 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SPFL1020 TYPE STANDARD TABLE OF SPFL1020,
      WA_SPFL1020 TYPE SPFL1020,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SPFL1020> TYPE SPFL1020.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SPFL1020.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SPFL1020
  INTO TABLE IT_SPFL1020.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SPFL1020
*  INTO TABLE @DATA(IT_SPFL10202).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SPFL1020 INDEX 1 INTO DATA(WA_SPFL10202).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SPFL1020 ASSIGNING <SPFL1020>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SPFL1020>-PFNAME = 1.
<SPFL1020>-VERSNR = 1.
<SPFL1020>-TXT = 1.
<SPFL1020>-TYPE = 1.
<SPFL1020>-STATE = 1.
ENDLOOP.

LOOP AT IT_SPFL1020 INTO WA_SPFL1020.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SPFL1020-CREFPF, sy-vline,
WA_SPFL1020-MDATE, sy-vline,
WA_SPFL1020-MTIME, sy-vline,
WA_SPFL1020-MUSR, sy-vline,
WA_SPFL1020-GDATE, sy-vline,
WA_SPFL1020-GTIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SPFL1020 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SPFL1020 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SPFL1020 INTO WA_SPFL1020. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SPFL1020_STR,
PFNAME TYPE STRING,
VERSNR TYPE STRING,
TXT TYPE STRING,
TYPE TYPE STRING,
STATE TYPE STRING,
CREFPF TYPE STRING,
MDATE TYPE STRING,
MTIME TYPE STRING,
MUSR TYPE STRING,
GDATE TYPE STRING,
GTIME TYPE STRING,
GUSR TYPE STRING,
PFFILE TYPE STRING,
OPSYS TYPE STRING,
SYSNR TYPE STRING,
SYSNAME TYPE STRING,
SERVERNAME TYPE STRING,
DEFAULTPFL TYPE STRING,
STARTPFL TYPE STRING,
INSTANCPFL TYPE STRING,END OF T_EKKO_STR. DATA: WA_SPFL1020_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SPFL1020_STR-PFNAME sy-vline
WA_SPFL1020_STR-VERSNR sy-vline
WA_SPFL1020_STR-TXT sy-vline
WA_SPFL1020_STR-TYPE sy-vline
WA_SPFL1020_STR-STATE sy-vline
WA_SPFL1020_STR-CREFPF sy-vline
WA_SPFL1020_STR-MDATE sy-vline
WA_SPFL1020_STR-MTIME sy-vline
WA_SPFL1020_STR-MUSR sy-vline
WA_SPFL1020_STR-GDATE sy-vline
WA_SPFL1020_STR-GTIME sy-vline
WA_SPFL1020_STR-GUSR sy-vline
WA_SPFL1020_STR-PFFILE sy-vline
WA_SPFL1020_STR-OPSYS sy-vline
WA_SPFL1020_STR-SYSNR sy-vline
WA_SPFL1020_STR-SYSNAME sy-vline
WA_SPFL1020_STR-SERVERNAME sy-vline
WA_SPFL1020_STR-DEFAULTPFL sy-vline
WA_SPFL1020_STR-STARTPFL sy-vline
WA_SPFL1020_STR-INSTANCPFL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.