ABAP Select data from SAP table SOFMO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SOFMO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SOFMO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SOFMO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SOFMO TYPE STANDARD TABLE OF SOFMO,
      WA_SOFMO TYPE SOFMO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SOFMO> TYPE SOFMO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SOFMO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SOFMO
  INTO TABLE IT_SOFMO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SOFMO
*  INTO TABLE @DATA(IT_SOFMO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SOFMO INDEX 1 INTO DATA(WA_SOFMO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SOFMO ASSIGNING <SOFMO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SOFMO>-FOLTP = 1.
<SOFMO>-FOLYR = 1.
<SOFMO>-FOLNO = 1.
<SOFMO>-DOCTP = 1.
<SOFMO>-DOCYR = 1.
ENDLOOP.

LOOP AT IT_SOFMO INTO WA_SOFMO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SOFMO-DOCNO, sy-vline,
WA_SOFMO-FORTP, sy-vline,
WA_SOFMO-FORYR, sy-vline,
WA_SOFMO-FORNO, sy-vline,
WA_SOFMO-PERMA, sy-vline,
WA_SOFMO-HOLDO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SOFMO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SOFMO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SOFMO INTO WA_SOFMO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SOFMO_STR,
FOLTP TYPE STRING,
FOLYR TYPE STRING,
FOLNO TYPE STRING,
DOCTP TYPE STRING,
DOCYR TYPE STRING,
DOCNO TYPE STRING,
FORTP TYPE STRING,
FORYR TYPE STRING,
FORNO TYPE STRING,
PERMA TYPE STRING,
HOLDO TYPE STRING,
ARCHI TYPE STRING,
DLDAT TYPE STRING,
DLTIM TYPE STRING,
NOTTP TYPE STRING,
NOTYR TYPE STRING,
NOTNO TYPE STRING,
RCDAT TYPE STRING,
RCTIM TYPE STRING,
SNDDR TYPE STRING,
SNDEX TYPE STRING,
SNDCP TYPE STRING,
SNDBC TYPE STRING,
OBJAC TYPE STRING,
OBJRR TYPE STRING,
OBJRD TYPE STRING,
RESUB TYPE STRING,
RECPRI TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
FLAG5 TYPE STRING,
RBDAT TYPE STRING,
LFOLTP TYPE STRING,
LFOLYR TYPE STRING,
LFOLNO TYPE STRING,END OF T_EKKO_STR. DATA: WA_SOFMO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SOFMO_STR-FOLTP sy-vline
WA_SOFMO_STR-FOLYR sy-vline
WA_SOFMO_STR-FOLNO sy-vline
WA_SOFMO_STR-DOCTP sy-vline
WA_SOFMO_STR-DOCYR sy-vline
WA_SOFMO_STR-DOCNO sy-vline
WA_SOFMO_STR-FORTP sy-vline
WA_SOFMO_STR-FORYR sy-vline
WA_SOFMO_STR-FORNO sy-vline
WA_SOFMO_STR-PERMA sy-vline
WA_SOFMO_STR-HOLDO sy-vline
WA_SOFMO_STR-ARCHI sy-vline
WA_SOFMO_STR-DLDAT sy-vline
WA_SOFMO_STR-DLTIM sy-vline
WA_SOFMO_STR-NOTTP sy-vline
WA_SOFMO_STR-NOTYR sy-vline
WA_SOFMO_STR-NOTNO sy-vline
WA_SOFMO_STR-RCDAT sy-vline
WA_SOFMO_STR-RCTIM sy-vline
WA_SOFMO_STR-SNDDR sy-vline
WA_SOFMO_STR-SNDEX sy-vline
WA_SOFMO_STR-SNDCP sy-vline
WA_SOFMO_STR-SNDBC sy-vline
WA_SOFMO_STR-OBJAC sy-vline
WA_SOFMO_STR-OBJRR sy-vline
WA_SOFMO_STR-OBJRD sy-vline
WA_SOFMO_STR-RESUB sy-vline
WA_SOFMO_STR-RECPRI sy-vline
WA_SOFMO_STR-FLAG1 sy-vline
WA_SOFMO_STR-FLAG2 sy-vline
WA_SOFMO_STR-FLAG3 sy-vline
WA_SOFMO_STR-FLAG4 sy-vline
WA_SOFMO_STR-FLAG5 sy-vline
WA_SOFMO_STR-RBDAT sy-vline
WA_SOFMO_STR-LFOLTP sy-vline
WA_SOFMO_STR-LFOLYR sy-vline
WA_SOFMO_STR-LFOLNO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.