ABAP Select data from SAP table SMB_UIE_EXCEP_MSG_LT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SMB_UIE_EXCEP_MSG_LT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SMB_UIE_EXCEP_MSG_LT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SMB_UIE_EXCEP_MSG_LT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SMB_UIE_EXCEP_MSG_LT TYPE STANDARD TABLE OF SMB_UIE_EXCEP_MSG_LT,
      WA_SMB_UIE_EXCEP_MSG_LT TYPE SMB_UIE_EXCEP_MSG_LT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SMB_UIE_EXCEP_MSG_LT> TYPE SMB_UIE_EXCEP_MSG_LT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SMB_UIE_EXCEP_MSG_LT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SMB_UIE_EXCEP_MSG_LT
  INTO TABLE IT_SMB_UIE_EXCEP_MSG_LT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SMB_UIE_EXCEP_MSG_LT
*  INTO TABLE @DATA(IT_SMB_UIE_EXCEP_MSG_LT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SMB_UIE_EXCEP_MSG_LT INDEX 1 INTO DATA(WA_SMB_UIE_EXCEP_MSG_LT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SMB_UIE_EXCEP_MSG_LT ASSIGNING <SMB_UIE_EXCEP_MSG_LT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SMB_UIE_EXCEP_MSG_LT>-PLWRK = 1.
<SMB_UIE_EXCEP_MSG_LT>-DISPO = 1.
<SMB_UIE_EXCEP_MSG_LT>-FEVOR = 1.
<SMB_UIE_EXCEP_MSG_LT>-AUSZ1 = 1.
<SMB_UIE_EXCEP_MSG_LT>-AUSZ2 = 1.
ENDLOOP.

LOOP AT IT_SMB_UIE_EXCEP_MSG_LT INTO WA_SMB_UIE_EXCEP_MSG_LT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SMB_UIE_EXCEP_MSG_LT-AUSZ3, sy-vline,
WA_SMB_UIE_EXCEP_MSG_LT-AUSZ4, sy-vline,
WA_SMB_UIE_EXCEP_MSG_LT-AUSZ5, sy-vline,
WA_SMB_UIE_EXCEP_MSG_LT-AUSZ6, sy-vline,
WA_SMB_UIE_EXCEP_MSG_LT-AUSZ7, sy-vline,
WA_SMB_UIE_EXCEP_MSG_LT-AUSZ8, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SMB_UIE_EXCEP_MSG_LT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SMB_UIE_EXCEP_MSG_LT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SMB_UIE_EXCEP_MSG_LT INTO WA_SMB_UIE_EXCEP_MSG_LT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SMB_UIE_EXCEP_MSG_LT_STR,
PLWRK TYPE STRING,
DISPO TYPE STRING,
FEVOR TYPE STRING,
AUSZ1 TYPE STRING,
AUSZ2 TYPE STRING,
AUSZ3 TYPE STRING,
AUSZ4 TYPE STRING,
AUSZ5 TYPE STRING,
AUSZ6 TYPE STRING,
AUSZ7 TYPE STRING,
AUSZ8 TYPE STRING,END OF T_EKKO_STR. DATA: WA_SMB_UIE_EXCEP_MSG_LT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SMB_UIE_EXCEP_MSG_LT_STR-PLWRK sy-vline
WA_SMB_UIE_EXCEP_MSG_LT_STR-DISPO sy-vline
WA_SMB_UIE_EXCEP_MSG_LT_STR-FEVOR sy-vline
WA_SMB_UIE_EXCEP_MSG_LT_STR-AUSZ1 sy-vline
WA_SMB_UIE_EXCEP_MSG_LT_STR-AUSZ2 sy-vline
WA_SMB_UIE_EXCEP_MSG_LT_STR-AUSZ3 sy-vline
WA_SMB_UIE_EXCEP_MSG_LT_STR-AUSZ4 sy-vline
WA_SMB_UIE_EXCEP_MSG_LT_STR-AUSZ5 sy-vline
WA_SMB_UIE_EXCEP_MSG_LT_STR-AUSZ6 sy-vline
WA_SMB_UIE_EXCEP_MSG_LT_STR-AUSZ7 sy-vline
WA_SMB_UIE_EXCEP_MSG_LT_STR-AUSZ8 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.