ABAP Select data from SAP table SLL_PRODCMDTYCDCLS_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SLL_PRODCMDTYCDCLS_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SLL_PRODCMDTYCDCLS_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SLL_PRODCMDTYCDCLS_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SLL_PRODCMDTYCDCLS_S TYPE STANDARD TABLE OF SLL_PRODCMDTYCDCLS_S,
      WA_SLL_PRODCMDTYCDCLS_S TYPE SLL_PRODCMDTYCDCLS_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SLL_PRODCMDTYCDCLS_S> TYPE SLL_PRODCMDTYCDCLS_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SLL_PRODCMDTYCDCLS_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SLL_PRODCMDTYCDCLS_S
  INTO TABLE IT_SLL_PRODCMDTYCDCLS_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SLL_PRODCMDTYCDCLS_S
*  INTO TABLE @DATA(IT_SLL_PRODCMDTYCDCLS_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SLL_PRODCMDTYCDCLS_S INDEX 1 INTO DATA(WA_SLL_PRODCMDTYCDCLS_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SLL_PRODCMDTYCDCLS_S ASSIGNING <SLL_PRODCMDTYCDCLS_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SLL_PRODCMDTYCDCLS_S>-MATNR = 1.
<SLL_PRODCMDTYCDCLS_S>-MAKTX = 1.
<SLL_PRODCMDTYCDCLS_S>-STCTS = 1.
<SLL_PRODCMDTYCDCLS_S>-STCTS_TEXT = 1.
<SLL_PRODCMDTYCDCLS_S>-DATAB = 1.
ENDLOOP.

LOOP AT IT_SLL_PRODCMDTYCDCLS_S INTO WA_SLL_PRODCMDTYCDCLS_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SLL_PRODCMDTYCDCLS_S-DATBI, sy-vline,
WA_SLL_PRODCMDTYCDCLS_S-COMCO, sy-vline,
WA_SLL_PRODCMDTYCDCLS_S-COMCO_TEXT, sy-vline,
WA_SLL_PRODCMDTYCDCLS_S-COMCO_OFCL_TEXT, sy-vline,
WA_SLL_PRODCMDTYCDCLS_S-COMCO_CCTND_TEXT, sy-vline,
WA_SLL_PRODCMDTYCDCLS_S-COMCO_DATAB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SLL_PRODCMDTYCDCLS_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SLL_PRODCMDTYCDCLS_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SLL_PRODCMDTYCDCLS_S INTO WA_SLL_PRODCMDTYCDCLS_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_SLL_PRODCMDTYCDCLS_S-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SLL_PRODCMDTYCDCLS_S-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BEMEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_SLL_PRODCMDTYCDCLS_S-BEMEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SLL_PRODCMDTYCDCLS_S-BEMEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BEME2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_SLL_PRODCMDTYCDCLS_S-BEME2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SLL_PRODCMDTYCDCLS_S-BEME2.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SLL_PRODCMDTYCDCLS_S_STR,
MATNR TYPE STRING,
MAKTX TYPE STRING,
STCTS TYPE STRING,
STCTS_TEXT TYPE STRING,
DATAB TYPE STRING,
DATBI TYPE STRING,
COMCO TYPE STRING,
COMCO_TEXT TYPE STRING,
COMCO_OFCL_TEXT TYPE STRING,
COMCO_CCTND_TEXT TYPE STRING,
COMCO_DATAB TYPE STRING,
COMCO_DATBI TYPE STRING,
TCLRM TYPE STRING,
BEMEH TYPE STRING,
MSEHL TYPE STRING,
BEME2 TYPE STRING,
MSEHL2 TYPE STRING,
CUOM1 TYPE STRING,
CUOM2 TYPE STRING,
CUOMT TYPE STRING,
CUOMT2 TYPE STRING,
WERKS TYPE STRING,
LAND1 TYPE STRING,
LCHG_DATE_TIME TYPE STRING,
LCHG_UNAME TYPE STRING,
USERDESCRIPTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_SLL_PRODCMDTYCDCLS_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-MATNR sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-MAKTX sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-STCTS sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-STCTS_TEXT sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-DATAB sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-DATBI sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-COMCO sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-COMCO_TEXT sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-COMCO_OFCL_TEXT sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-COMCO_CCTND_TEXT sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-COMCO_DATAB sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-COMCO_DATBI sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-TCLRM sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-BEMEH sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-MSEHL sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-BEME2 sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-MSEHL2 sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-CUOM1 sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-CUOM2 sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-CUOMT sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-CUOMT2 sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-WERKS sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-LAND1 sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-LCHG_DATE_TIME sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-LCHG_UNAME sy-vline
WA_SLL_PRODCMDTYCDCLS_S_STR-USERDESCRIPTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.