ABAP Select data from SAP table SITE_DISTR_ADDR3_COMPLETE_STY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SITE_DISTR_ADDR3_COMPLETE_STY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SITE_DISTR_ADDR3_COMPLETE_STY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SITE_DISTR_ADDR3_COMPLETE_STY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SITE_DISTR_ADDR3_COMPLETE_STY TYPE STANDARD TABLE OF SITE_DISTR_ADDR3_COMPLETE_STY,
      WA_SITE_DISTR_ADDR3_COMPLETE_STY TYPE SITE_DISTR_ADDR3_COMPLETE_STY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SITE_DISTR_ADDR3_COMPLETE_STY> TYPE SITE_DISTR_ADDR3_COMPLETE_STY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SITE_DISTR_ADDR3_COMPLETE_STY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SITE_DISTR_ADDR3_COMPLETE_STY
  INTO TABLE IT_SITE_DISTR_ADDR3_COMPLETE_STY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SITE_DISTR_ADDR3_COMPLETE_STY
*  INTO TABLE @DATA(IT_SITE_DISTR_ADDR3_COMPLETE_STY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SITE_DISTR_ADDR3_COMPLETE_STY INDEX 1 INTO DATA(WA_SITE_DISTR_ADDR3_COMPLETE_STY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SITE_DISTR_ADDR3_COMPLETE_STY ASSIGNING <SITE_DISTR_ADDR3_COMPLETE_STY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SITE_DISTR_ADDR3_COMPLETE_STY>-ADDRNUMBER = 1.
<SITE_DISTR_ADDR3_COMPLETE_STY>-ADDRHANDLE = 1.
<SITE_DISTR_ADDR3_COMPLETE_STY>-PERSNUMBER = 1.
<SITE_DISTR_ADDR3_COMPLETE_STY>-PERSHANDLE = 1.
<SITE_DISTR_ADDR3_COMPLETE_STY>-ADDR3_TAB = 1.
ENDLOOP.

LOOP AT IT_SITE_DISTR_ADDR3_COMPLETE_STY INTO WA_SITE_DISTR_ADDR3_COMPLETE_STY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SITE_DISTR_ADDR3_COMPLETE_STY-ADTEL_TAB, sy-vline,
WA_SITE_DISTR_ADDR3_COMPLETE_STY-ADFAX_TAB, sy-vline,
WA_SITE_DISTR_ADDR3_COMPLETE_STY-ADTTX_TAB, sy-vline,
WA_SITE_DISTR_ADDR3_COMPLETE_STY-ADTLX_TAB, sy-vline,
WA_SITE_DISTR_ADDR3_COMPLETE_STY-ADSMTP_TAB, sy-vline,
WA_SITE_DISTR_ADDR3_COMPLETE_STY-ADRML_TAB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SITE_DISTR_ADDR3_COMPLETE_STY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SITE_DISTR_ADDR3_COMPLETE_STY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SITE_DISTR_ADDR3_COMPLETE_STY INTO WA_SITE_DISTR_ADDR3_COMPLETE_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ADDRNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITE_DISTR_ADDR3_COMPLETE_STY-ADDRNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITE_DISTR_ADDR3_COMPLETE_STY-ADDRNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PERSNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITE_DISTR_ADDR3_COMPLETE_STY-PERSNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITE_DISTR_ADDR3_COMPLETE_STY-PERSNUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SITE_DISTR_ADDR3_COMPLETE_STY_STR,
ADDRNUMBER TYPE STRING,
ADDRHANDLE TYPE STRING,
PERSNUMBER TYPE STRING,
PERSHANDLE TYPE STRING,
ADDR3_TAB TYPE STRING,
ADTEL_TAB TYPE STRING,
ADFAX_TAB TYPE STRING,
ADTTX_TAB TYPE STRING,
ADTLX_TAB TYPE STRING,
ADSMTP_TAB TYPE STRING,
ADRML_TAB TYPE STRING,
ADX400_TAB TYPE STRING,
ADRFC_TAB TYPE STRING,
ADPRT_TAB TYPE STRING,
ADSSF_TAB TYPE STRING,
ADURI_TAB TYPE STRING,
ADPAG_TAB TYPE STRING,
ADRT_TAB TYPE STRING,
ADRU_TAB TYPE STRING,END OF T_EKKO_STR. DATA: WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADDRNUMBER sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADDRHANDLE sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-PERSNUMBER sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-PERSHANDLE sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADDR3_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADTEL_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADFAX_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADTTX_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADTLX_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADSMTP_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADRML_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADX400_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADRFC_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADPRT_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADSSF_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADURI_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADPAG_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADRT_TAB sy-vline
WA_SITE_DISTR_ADDR3_COMPLETE_STY_STR-ADRU_TAB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.