ABAP Select data from SAP table SITAGCYFKKMAKO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SITAGCYFKKMAKO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SITAGCYFKKMAKO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SITAGCYFKKMAKO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SITAGCYFKKMAKO TYPE STANDARD TABLE OF SITAGCYFKKMAKO,
      WA_SITAGCYFKKMAKO TYPE SITAGCYFKKMAKO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SITAGCYFKKMAKO> TYPE SITAGCYFKKMAKO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SITAGCYFKKMAKO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SITAGCYFKKMAKO
  INTO TABLE IT_SITAGCYFKKMAKO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SITAGCYFKKMAKO
*  INTO TABLE @DATA(IT_SITAGCYFKKMAKO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SITAGCYFKKMAKO INDEX 1 INTO DATA(WA_SITAGCYFKKMAKO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SITAGCYFKKMAKO ASSIGNING <SITAGCYFKKMAKO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SITAGCYFKKMAKO>-GUID = 1.
<SITAGCYFKKMAKO>-MANDT = 1.
<SITAGCYFKKMAKO>-LAUFD = 1.
<SITAGCYFKKMAKO>-LAUFI = 1.
<SITAGCYFKKMAKO>-GPART = 1.
ENDLOOP.

LOOP AT IT_SITAGCYFKKMAKO INTO WA_SITAGCYFKKMAKO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SITAGCYFKKMAKO-VKONT, sy-vline,
WA_SITAGCYFKKMAKO-MAZAE, sy-vline,
WA_SITAGCYFKKMAKO-AUSDT, sy-vline,
WA_SITAGCYFKKMAKO-MDRKD, sy-vline,
WA_SITAGCYFKKMAKO-MAHNV, sy-vline,
WA_SITAGCYFKKMAKO-MGRUP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SITAGCYFKKMAKO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SITAGCYFKKMAKO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SITAGCYFKKMAKO INTO WA_SITAGCYFKKMAKO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VTREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-VTREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-VTREF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKNT1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-VKNT1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-VKNT1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ABWMA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-ABWMA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-ABWMA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MG1BL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-MG1BL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-MG1BL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MG2BL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-MG2BL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-MG2BL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MG3BL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-MG3BL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-MG3BL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MIBEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-MIBEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-MIBEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NRZAS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-NRZAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-NRZAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DEBT_SET_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-DEBT_SET_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-DEBT_SET_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ABWBL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SITAGCYFKKMAKO-ABWBL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SITAGCYFKKMAKO-ABWBL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SITAGCYFKKMAKO_STR,
GUID TYPE STRING,
MANDT TYPE STRING,
LAUFD TYPE STRING,
LAUFI TYPE STRING,
GPART TYPE STRING,
VKONT TYPE STRING,
MAZAE TYPE STRING,
AUSDT TYPE STRING,
MDRKD TYPE STRING,
MAHNV TYPE STRING,
MGRUP TYPE STRING,
VKONTGRP TYPE STRING,
VTREFGRP TYPE STRING,
ITEMGRP TYPE STRING,
ITEMGRP_LAST TYPE STRING,
GRPFIELD TYPE STRING,
GRPFIELD_LAST TYPE STRING,
STRAT TYPE STRING,
STEP TYPE STRING,
STEP_LAST TYPE STRING,
STEP_REPLACED TYPE STRING,
STRAT_CHAMP TYPE STRING,
TESTS TYPE STRING,
LIMITED TYPE STRING,
RELEA TYPE STRING,
RELDATE TYPE STRING,
RELGROUP TYPE STRING,
NEXDT TYPE STRING,
OPBUK TYPE STRING,
STDBK TYPE STRING,
GSBER TYPE STRING,
SPART TYPE STRING,
VTREF TYPE STRING,
SUBAP TYPE STRING,
VKNT1 TYPE STRING,
ABWMA TYPE STRING,
MAHNS TYPE STRING,
MSTYP TYPE STRING,
WAERS TYPE STRING,
MSALM TYPE STRING,
MSALH TYPE STRING,
RSALM TYPE STRING,
CHGID TYPE STRING,
MGE1M TYPE STRING,
MG1BL TYPE STRING,
MG1TY TYPE STRING,
POST1 TYPE STRING,
MGE2M TYPE STRING,
MG2BL TYPE STRING,
MG2TY TYPE STRING,
POST2 TYPE STRING,
MGE3M TYPE STRING,
MG3BL TYPE STRING,
MG3TY TYPE STRING,
POST3 TYPE STRING,
MINTM TYPE STRING,
MIBEL TYPE STRING,
BONIT TYPE STRING,
XMSTO TYPE STRING,
NRZAS TYPE STRING,
XINFO TYPE STRING,
FRDAT TYPE STRING,
COKEY TYPE STRING,
XCOLL TYPE STRING,
RFZAS TYPE STRING,
TODAT TYPE STRING,
STAKZ TYPE STRING,
CHECKBOX TYPE STRING,
DEBT_SET_NUMBER TYPE STRING,
SUCPC TYPE STRING,
ABWTP TYPE STRING,
ABWBL TYPE STRING,
STUDT TYPE STRING,
SUCDT TYPE STRING,
SCDST TYPE STRING,
COLOGRP TYPE STRING,
FORMKEY TYPE STRING,
SCORE TYPE STRING,
RANK TYPE STRING,
LOCKR TYPE STRING,
MAZE TYPE STRING,END OF T_EKKO_STR. DATA: WA_SITAGCYFKKMAKO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SITAGCYFKKMAKO_STR-GUID sy-vline
WA_SITAGCYFKKMAKO_STR-MANDT sy-vline
WA_SITAGCYFKKMAKO_STR-LAUFD sy-vline
WA_SITAGCYFKKMAKO_STR-LAUFI sy-vline
WA_SITAGCYFKKMAKO_STR-GPART sy-vline
WA_SITAGCYFKKMAKO_STR-VKONT sy-vline
WA_SITAGCYFKKMAKO_STR-MAZAE sy-vline
WA_SITAGCYFKKMAKO_STR-AUSDT sy-vline
WA_SITAGCYFKKMAKO_STR-MDRKD sy-vline
WA_SITAGCYFKKMAKO_STR-MAHNV sy-vline
WA_SITAGCYFKKMAKO_STR-MGRUP sy-vline
WA_SITAGCYFKKMAKO_STR-VKONTGRP sy-vline
WA_SITAGCYFKKMAKO_STR-VTREFGRP sy-vline
WA_SITAGCYFKKMAKO_STR-ITEMGRP sy-vline
WA_SITAGCYFKKMAKO_STR-ITEMGRP_LAST sy-vline
WA_SITAGCYFKKMAKO_STR-GRPFIELD sy-vline
WA_SITAGCYFKKMAKO_STR-GRPFIELD_LAST sy-vline
WA_SITAGCYFKKMAKO_STR-STRAT sy-vline
WA_SITAGCYFKKMAKO_STR-STEP sy-vline
WA_SITAGCYFKKMAKO_STR-STEP_LAST sy-vline
WA_SITAGCYFKKMAKO_STR-STEP_REPLACED sy-vline
WA_SITAGCYFKKMAKO_STR-STRAT_CHAMP sy-vline
WA_SITAGCYFKKMAKO_STR-TESTS sy-vline
WA_SITAGCYFKKMAKO_STR-LIMITED sy-vline
WA_SITAGCYFKKMAKO_STR-RELEA sy-vline
WA_SITAGCYFKKMAKO_STR-RELDATE sy-vline
WA_SITAGCYFKKMAKO_STR-RELGROUP sy-vline
WA_SITAGCYFKKMAKO_STR-NEXDT sy-vline
WA_SITAGCYFKKMAKO_STR-OPBUK sy-vline
WA_SITAGCYFKKMAKO_STR-STDBK sy-vline
WA_SITAGCYFKKMAKO_STR-GSBER sy-vline
WA_SITAGCYFKKMAKO_STR-SPART sy-vline
WA_SITAGCYFKKMAKO_STR-VTREF sy-vline
WA_SITAGCYFKKMAKO_STR-SUBAP sy-vline
WA_SITAGCYFKKMAKO_STR-VKNT1 sy-vline
WA_SITAGCYFKKMAKO_STR-ABWMA sy-vline
WA_SITAGCYFKKMAKO_STR-MAHNS sy-vline
WA_SITAGCYFKKMAKO_STR-MSTYP sy-vline
WA_SITAGCYFKKMAKO_STR-WAERS sy-vline
WA_SITAGCYFKKMAKO_STR-MSALM sy-vline
WA_SITAGCYFKKMAKO_STR-MSALH sy-vline
WA_SITAGCYFKKMAKO_STR-RSALM sy-vline
WA_SITAGCYFKKMAKO_STR-CHGID sy-vline
WA_SITAGCYFKKMAKO_STR-MGE1M sy-vline
WA_SITAGCYFKKMAKO_STR-MG1BL sy-vline
WA_SITAGCYFKKMAKO_STR-MG1TY sy-vline
WA_SITAGCYFKKMAKO_STR-POST1 sy-vline
WA_SITAGCYFKKMAKO_STR-MGE2M sy-vline
WA_SITAGCYFKKMAKO_STR-MG2BL sy-vline
WA_SITAGCYFKKMAKO_STR-MG2TY sy-vline
WA_SITAGCYFKKMAKO_STR-POST2 sy-vline
WA_SITAGCYFKKMAKO_STR-MGE3M sy-vline
WA_SITAGCYFKKMAKO_STR-MG3BL sy-vline
WA_SITAGCYFKKMAKO_STR-MG3TY sy-vline
WA_SITAGCYFKKMAKO_STR-POST3 sy-vline
WA_SITAGCYFKKMAKO_STR-MINTM sy-vline
WA_SITAGCYFKKMAKO_STR-MIBEL sy-vline
WA_SITAGCYFKKMAKO_STR-BONIT sy-vline
WA_SITAGCYFKKMAKO_STR-XMSTO sy-vline
WA_SITAGCYFKKMAKO_STR-NRZAS sy-vline
WA_SITAGCYFKKMAKO_STR-XINFO sy-vline
WA_SITAGCYFKKMAKO_STR-FRDAT sy-vline
WA_SITAGCYFKKMAKO_STR-COKEY sy-vline
WA_SITAGCYFKKMAKO_STR-XCOLL sy-vline
WA_SITAGCYFKKMAKO_STR-RFZAS sy-vline
WA_SITAGCYFKKMAKO_STR-TODAT sy-vline
WA_SITAGCYFKKMAKO_STR-STAKZ sy-vline
WA_SITAGCYFKKMAKO_STR-CHECKBOX sy-vline
WA_SITAGCYFKKMAKO_STR-DEBT_SET_NUMBER sy-vline
WA_SITAGCYFKKMAKO_STR-SUCPC sy-vline
WA_SITAGCYFKKMAKO_STR-ABWTP sy-vline
WA_SITAGCYFKKMAKO_STR-ABWBL sy-vline
WA_SITAGCYFKKMAKO_STR-STUDT sy-vline
WA_SITAGCYFKKMAKO_STR-SUCDT sy-vline
WA_SITAGCYFKKMAKO_STR-SCDST sy-vline
WA_SITAGCYFKKMAKO_STR-COLOGRP sy-vline
WA_SITAGCYFKKMAKO_STR-FORMKEY sy-vline
WA_SITAGCYFKKMAKO_STR-SCORE sy-vline
WA_SITAGCYFKKMAKO_STR-RANK sy-vline
WA_SITAGCYFKKMAKO_STR-LOCKR sy-vline
WA_SITAGCYFKKMAKO_STR-MAZE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.