ABAP Select data from SAP table SICJIT_SETTINGS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SICJIT_SETTINGS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SICJIT_SETTINGS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SICJIT_SETTINGS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SICJIT_SETTINGS TYPE STANDARD TABLE OF SICJIT_SETTINGS,
      WA_SICJIT_SETTINGS TYPE SICJIT_SETTINGS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SICJIT_SETTINGS> TYPE SICJIT_SETTINGS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SICJIT_SETTINGS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SICJIT_SETTINGS
  INTO TABLE IT_SICJIT_SETTINGS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SICJIT_SETTINGS
*  INTO TABLE @DATA(IT_SICJIT_SETTINGS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SICJIT_SETTINGS INDEX 1 INTO DATA(WA_SICJIT_SETTINGS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SICJIT_SETTINGS ASSIGNING <SICJIT_SETTINGS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SICJIT_SETTINGS>-MANDT = 1.
<SICJIT_SETTINGS>-UNAME = 1.
<SICJIT_SETTINGS>-LIFNR = 1.
<SICJIT_SETTINGS>-LOCNO = 1.
<SICJIT_SETTINGS>-LSTAT = 1.
ENDLOOP.

LOOP AT IT_SICJIT_SETTINGS INTO WA_SICJIT_SETTINGS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SICJIT_SETTINGS-USTAT, sy-vline,
WA_SICJIT_SETTINGS-TOFFL, sy-vline,
WA_SICJIT_SETTINGS-TOFFU, sy-vline,
WA_SICJIT_SETTINGS-VIEWS, sy-vline,
WA_SICJIT_SETTINGS-SORTB, sy-vline,
ENDLOOP. *Add any further fields from structure WA_SICJIT_SETTINGS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SICJIT_SETTINGS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SICJIT_SETTINGS INTO WA_SICJIT_SETTINGS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SICJIT_SETTINGS-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SICJIT_SETTINGS-LIFNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SICJIT_SETTINGS_STR,
MANDT TYPE STRING,
UNAME TYPE STRING,
LIFNR TYPE STRING,
LOCNO TYPE STRING,
LSTAT TYPE STRING,
USTAT TYPE STRING,
TOFFL TYPE STRING,
TOFFU TYPE STRING,
VIEWS TYPE STRING,
SORTB TYPE STRING,END OF T_EKKO_STR. DATA: WA_SICJIT_SETTINGS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SICJIT_SETTINGS_STR-MANDT sy-vline
WA_SICJIT_SETTINGS_STR-UNAME sy-vline
WA_SICJIT_SETTINGS_STR-LIFNR sy-vline
WA_SICJIT_SETTINGS_STR-LOCNO sy-vline
WA_SICJIT_SETTINGS_STR-LSTAT sy-vline
WA_SICJIT_SETTINGS_STR-USTAT sy-vline
WA_SICJIT_SETTINGS_STR-TOFFL sy-vline
WA_SICJIT_SETTINGS_STR-TOFFU sy-vline
WA_SICJIT_SETTINGS_STR-VIEWS sy-vline
WA_SICJIT_SETTINGS_STR-SORTB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.