ABAP Select data from SAP table SI_REAL_EST_OBJ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SI_REAL_EST_OBJ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SI_REAL_EST_OBJ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SI_REAL_EST_OBJ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SI_REAL_EST_OBJ TYPE STANDARD TABLE OF SI_REAL_EST_OBJ,
      WA_SI_REAL_EST_OBJ TYPE SI_REAL_EST_OBJ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SI_REAL_EST_OBJ> TYPE SI_REAL_EST_OBJ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SI_REAL_EST_OBJ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SI_REAL_EST_OBJ
  INTO TABLE IT_SI_REAL_EST_OBJ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SI_REAL_EST_OBJ
*  INTO TABLE @DATA(IT_SI_REAL_EST_OBJ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SI_REAL_EST_OBJ INDEX 1 INTO DATA(WA_SI_REAL_EST_OBJ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SI_REAL_EST_OBJ ASSIGNING <SI_REAL_EST_OBJ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SI_REAL_EST_OBJ>-SRE_COMP_CODE = 1.
<SI_REAL_EST_OBJ>-SRE_BUS_ENT = 1.
<SI_REAL_EST_OBJ>-SRE_PROPERTY = 1.
<SI_REAL_EST_OBJ>-SRE_BUILDING = 1.
<SI_REAL_EST_OBJ>-SRE_RENT_UNIT = 1.
ENDLOOP.

LOOP AT IT_SI_REAL_EST_OBJ INTO WA_SI_REAL_EST_OBJ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SI_REAL_EST_OBJ-SRE_LEASE, sy-vline,
WA_SI_REAL_EST_OBJ-SRE_MGMT_CON, sy-vline,
WA_SI_REAL_EST_OBJ-SRE_INC_EXP, sy-vline,
WA_SI_REAL_EST_OBJ-SRE_SETT_UNIT, sy-vline,
WA_SI_REAL_EST_OBJ-SRE_REF_DATE, sy-vline,
WA_SI_REAL_EST_OBJ-SRE_CON_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SI_REAL_EST_OBJ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SI_REAL_EST_OBJ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SI_REAL_EST_OBJ INTO WA_SI_REAL_EST_OBJ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SWENR, internal->external for field SRE_BUS_ENT CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-SRE_BUS_ENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-SRE_BUS_ENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SGRNR, internal->external for field SRE_PROPERTY CALL FUNCTION 'CONVERSION_EXIT_SGRNR_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-SRE_PROPERTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-SRE_PROPERTY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SGENR, internal->external for field SRE_BUILDING CALL FUNCTION 'CONVERSION_EXIT_SGENR_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-SRE_BUILDING IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-SRE_BUILDING.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SMENR, internal->external for field SRE_RENT_UNIT CALL FUNCTION 'CONVERSION_EXIT_SMENR_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-SRE_RENT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-SRE_RENT_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SRE_LEASE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-SRE_LEASE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-SRE_LEASE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SRE_MGMT_CON CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-SRE_MGMT_CON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-SRE_MGMT_CON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SRE_INC_EXP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-SRE_INC_EXP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-SRE_INC_EXP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SRE_SETT_UNIT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-SRE_SETT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-SRE_SETT_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SRE_CON_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-SRE_CON_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-SRE_CON_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SWENR, internal->external for field RRE_BUS_ENT CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-RRE_BUS_ENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-RRE_BUS_ENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SGRNR, internal->external for field RRE_PROPERTY CALL FUNCTION 'CONVERSION_EXIT_SGRNR_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-RRE_PROPERTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-RRE_PROPERTY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SGENR, internal->external for field RRE_BUILDING CALL FUNCTION 'CONVERSION_EXIT_SGENR_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-RRE_BUILDING IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-RRE_BUILDING.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SMENR, internal->external for field RRE_RENT_UNIT CALL FUNCTION 'CONVERSION_EXIT_SMENR_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-RRE_RENT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-RRE_RENT_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RRE_LEASE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-RRE_LEASE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-RRE_LEASE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RRE_MGMT_CON CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-RRE_MGMT_CON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-RRE_MGMT_CON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RRE_INC_EXP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-RRE_INC_EXP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-RRE_INC_EXP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RRE_SETT_UNIT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-RRE_SETT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-RRE_SETT_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RRE_CON_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SI_REAL_EST_OBJ-RRE_CON_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SI_REAL_EST_OBJ-RRE_CON_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SI_REAL_EST_OBJ_STR,
SRE_COMP_CODE TYPE STRING,
SRE_BUS_ENT TYPE STRING,
SRE_PROPERTY TYPE STRING,
SRE_BUILDING TYPE STRING,
SRE_RENT_UNIT TYPE STRING,
SRE_LEASE TYPE STRING,
SRE_MGMT_CON TYPE STRING,
SRE_INC_EXP TYPE STRING,
SRE_SETT_UNIT TYPE STRING,
SRE_REF_DATE TYPE STRING,
SRE_CON_NO TYPE STRING,
RRE_COMP_CODE TYPE STRING,
RRE_BUS_ENT TYPE STRING,
RRE_PROPERTY TYPE STRING,
RRE_BUILDING TYPE STRING,
RRE_RENT_UNIT TYPE STRING,
RRE_LEASE TYPE STRING,
RRE_MGMT_CON TYPE STRING,
RRE_INC_EXP TYPE STRING,
RRE_SETT_UNIT TYPE STRING,
RRE_REF_DATE TYPE STRING,
RRE_CON_NO TYPE STRING,END OF T_EKKO_STR. DATA: WA_SI_REAL_EST_OBJ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SI_REAL_EST_OBJ_STR-SRE_COMP_CODE sy-vline
WA_SI_REAL_EST_OBJ_STR-SRE_BUS_ENT sy-vline
WA_SI_REAL_EST_OBJ_STR-SRE_PROPERTY sy-vline
WA_SI_REAL_EST_OBJ_STR-SRE_BUILDING sy-vline
WA_SI_REAL_EST_OBJ_STR-SRE_RENT_UNIT sy-vline
WA_SI_REAL_EST_OBJ_STR-SRE_LEASE sy-vline
WA_SI_REAL_EST_OBJ_STR-SRE_MGMT_CON sy-vline
WA_SI_REAL_EST_OBJ_STR-SRE_INC_EXP sy-vline
WA_SI_REAL_EST_OBJ_STR-SRE_SETT_UNIT sy-vline
WA_SI_REAL_EST_OBJ_STR-SRE_REF_DATE sy-vline
WA_SI_REAL_EST_OBJ_STR-SRE_CON_NO sy-vline
WA_SI_REAL_EST_OBJ_STR-RRE_COMP_CODE sy-vline
WA_SI_REAL_EST_OBJ_STR-RRE_BUS_ENT sy-vline
WA_SI_REAL_EST_OBJ_STR-RRE_PROPERTY sy-vline
WA_SI_REAL_EST_OBJ_STR-RRE_BUILDING sy-vline
WA_SI_REAL_EST_OBJ_STR-RRE_RENT_UNIT sy-vline
WA_SI_REAL_EST_OBJ_STR-RRE_LEASE sy-vline
WA_SI_REAL_EST_OBJ_STR-RRE_MGMT_CON sy-vline
WA_SI_REAL_EST_OBJ_STR-RRE_INC_EXP sy-vline
WA_SI_REAL_EST_OBJ_STR-RRE_SETT_UNIT sy-vline
WA_SI_REAL_EST_OBJ_STR-RRE_REF_DATE sy-vline
WA_SI_REAL_EST_OBJ_STR-RRE_CON_NO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.