ABAP Select data from SAP table SHSMKNVH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SHSMKNVH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SHSMKNVH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SHSMKNVH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SHSMKNVH TYPE STANDARD TABLE OF SHSMKNVH,
      WA_SHSMKNVH TYPE SHSMKNVH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SHSMKNVH> TYPE SHSMKNVH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SHSMKNVH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SHSMKNVH
  INTO TABLE IT_SHSMKNVH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SHSMKNVH
*  INTO TABLE @DATA(IT_SHSMKNVH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SHSMKNVH INDEX 1 INTO DATA(WA_SHSMKNVH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SHSMKNVH ASSIGNING <SHSMKNVH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SHSMKNVH>-MANDT = 1.
<SHSMKNVH>-KUNNR = 1.
<SHSMKNVH>-HITYP = 1.
<SHSMKNVH>-VKORG = 1.
<SHSMKNVH>-VTWEG = 1.
ENDLOOP.

LOOP AT IT_SHSMKNVH INTO WA_SHSMKNVH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SHSMKNVH-SPART, sy-vline,
WA_SHSMKNVH-DATAB, sy-vline,
WA_SHSMKNVH-HKUNNR, sy-vline,
WA_SHSMKNVH-HVKORG, sy-vline,
WA_SHSMKNVH-HVTWEG, sy-vline,
WA_SHSMKNVH-HSPART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SHSMKNVH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SHSMKNVH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SHSMKNVH INTO WA_SHSMKNVH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SHSMKNVH-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SHSMKNVH-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SHSMKNVH-HKUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SHSMKNVH-HKUNNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SHSMKNVH_STR,
MANDT TYPE STRING,
KUNNR TYPE STRING,
HITYP TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
DATAB TYPE STRING,
HKUNNR TYPE STRING,
HVKORG TYPE STRING,
HVTWEG TYPE STRING,
HSPART TYPE STRING,
DATBI TYPE STRING,END OF T_EKKO_STR. DATA: WA_SHSMKNVH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SHSMKNVH_STR-MANDT sy-vline
WA_SHSMKNVH_STR-KUNNR sy-vline
WA_SHSMKNVH_STR-HITYP sy-vline
WA_SHSMKNVH_STR-VKORG sy-vline
WA_SHSMKNVH_STR-VTWEG sy-vline
WA_SHSMKNVH_STR-SPART sy-vline
WA_SHSMKNVH_STR-DATAB sy-vline
WA_SHSMKNVH_STR-HKUNNR sy-vline
WA_SHSMKNVH_STR-HVKORG sy-vline
WA_SHSMKNVH_STR-HVTWEG sy-vline
WA_SHSMKNVH_STR-HSPART sy-vline
WA_SHSMKNVH_STR-DATBI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.