ABAP Select data from SAP table SETVALPTR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP SETVALPTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SETVALPTR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the SETVALPTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_SETVALPTR TYPE STANDARD TABLE OF SETVALPTR,
WA_SETVALPTR TYPE SETVALPTR,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SETVALPTR> TYPE SETVALPTR.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_SETVALPTR.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM SETVALPTR
INTO TABLE IT_SETVALPTR.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM SETVALPTR
* INTO TABLE @DATA(IT_SETVALPTR2).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SETVALPTR INDEX 1 INTO DATA(WA_SETVALPTR2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SETVALPTR ASSIGNING <SETVALPTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<SETVALPTR>-FROM = 1.
<SETVALPTR>-TO = 1.
<SETVALPTR>-OLD_LINE = 1.
<SETVALPTR>-XSUPPRESS = 1.
<SETVALPTR>-PMFLAG = 1.
ENDLOOP. LOOP AT IT_SETVALPTR INTO WA_SETVALPTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_SETVALPTR-LNAME, sy-vline,
WA_SETVALPTR-PFLAG, sy-vline,
WA_SETVALPTR-PRTCLASS, sy-vline,
WA_SETVALPTR-FORMULA, sy-vline,
WA_SETVALPTR-PFEED, sy-vline,
WA_SETVALPTR-LFIELDNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SETVALPTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SETVALPTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SETVALPTR INTO WA_SETVALPTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SETVALPTR_STR,
FROM TYPE STRING,
TO TYPE STRING,
OLD_LINE TYPE STRING,
XSUPPRESS TYPE STRING,
PMFLAG TYPE STRING,
LNAME TYPE STRING,
PFLAG TYPE STRING,
PRTCLASS TYPE STRING,
FORMULA TYPE STRING,
PFEED TYPE STRING,
LFIELDNAME TYPE STRING,
DESCRIPT TYPE STRING,
PUP TYPE STRING,
PNEXT TYPE STRING,
PPREV TYPE STRING,END OF T_EKKO_STR. DATA: WA_SETVALPTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SETVALPTR_STR-FROM sy-vline
WA_SETVALPTR_STR-TO sy-vline
WA_SETVALPTR_STR-OLD_LINE sy-vline
WA_SETVALPTR_STR-XSUPPRESS sy-vline
WA_SETVALPTR_STR-PMFLAG sy-vline
WA_SETVALPTR_STR-LNAME sy-vline
WA_SETVALPTR_STR-PFLAG sy-vline
WA_SETVALPTR_STR-PRTCLASS sy-vline
WA_SETVALPTR_STR-FORMULA sy-vline
WA_SETVALPTR_STR-PFEED sy-vline
WA_SETVALPTR_STR-LFIELDNAME sy-vline
WA_SETVALPTR_STR-DESCRIPT sy-vline
WA_SETVALPTR_STR-PUP sy-vline
WA_SETVALPTR_STR-PNEXT sy-vline
WA_SETVALPTR_STR-PPREV sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.