ABAP Select data from SAP table SDCFC_00000752 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SDCFC_00000752 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SDCFC_00000752. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SDCFC_00000752 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SDCFC_00000752 TYPE STANDARD TABLE OF SDCFC_00000752,
      WA_SDCFC_00000752 TYPE SDCFC_00000752,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SDCFC_00000752> TYPE SDCFC_00000752.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SDCFC_00000752.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SDCFC_00000752
  INTO TABLE IT_SDCFC_00000752.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SDCFC_00000752
*  INTO TABLE @DATA(IT_SDCFC_000007522).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SDCFC_00000752 INDEX 1 INTO DATA(WA_SDCFC_000007522).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SDCFC_00000752 ASSIGNING <SDCFC_00000752>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SDCFC_00000752>-QUALF = 1.
<SDCFC_00000752>-ICC = 1.
<SDCFC_00000752>-MOI = 1.
<SDCFC_00000752>-PRI = 1.
<SDCFC_00000752>-ACN = 1.
ENDLOOP.

LOOP AT IT_SDCFC_00000752 INTO WA_SDCFC_00000752.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SDCFC_00000752-ACN10, sy-vline,
WA_SDCFC_00000752-DNS, sy-vline,
WA_SDCFC_00000752-E1TXTH1, sy-vline,
WA_SDCFC_00000752-FUNCTION, sy-vline,
WA_SDCFC_00000752-TDOBJECT, sy-vline,
WA_SDCFC_00000752-TDOBNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SDCFC_00000752 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SDCFC_00000752 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SDCFC_00000752 INTO WA_SDCFC_00000752. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field TDSPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_SDCFC_00000752-TDSPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SDCFC_00000752-TDSPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SDCFC_00000752_STR,
QUALF TYPE STRING,
ICC TYPE STRING,
MOI TYPE STRING,
PRI TYPE STRING,
ACN TYPE STRING,
ACN10 TYPE STRING,
DNS TYPE STRING,
E1TXTH1 TYPE STRING,
FUNCTION TYPE STRING,
TDOBJECT TYPE STRING,
TDOBNAME TYPE STRING,
TDID TYPE STRING,
TDSPRAS TYPE STRING,
TDTEXTTYPE TYPE STRING,
LANGUA_ISO TYPE STRING,
E1TXTP1 TYPE STRING,END OF T_EKKO_STR. DATA: WA_SDCFC_00000752_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SDCFC_00000752_STR-QUALF sy-vline
WA_SDCFC_00000752_STR-ICC sy-vline
WA_SDCFC_00000752_STR-MOI sy-vline
WA_SDCFC_00000752_STR-PRI sy-vline
WA_SDCFC_00000752_STR-ACN sy-vline
WA_SDCFC_00000752_STR-ACN10 sy-vline
WA_SDCFC_00000752_STR-DNS sy-vline
WA_SDCFC_00000752_STR-E1TXTH1 sy-vline
WA_SDCFC_00000752_STR-FUNCTION sy-vline
WA_SDCFC_00000752_STR-TDOBJECT sy-vline
WA_SDCFC_00000752_STR-TDOBNAME sy-vline
WA_SDCFC_00000752_STR-TDID sy-vline
WA_SDCFC_00000752_STR-TDSPRAS sy-vline
WA_SDCFC_00000752_STR-TDTEXTTYPE sy-vline
WA_SDCFC_00000752_STR-LANGUA_ISO sy-vline
WA_SDCFC_00000752_STR-E1TXTP1 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.