ABAP Select data from SAP table SDCFC_00000731 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP SDCFC_00000731 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SDCFC_00000731. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the SDCFC_00000731 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_SDCFC_00000731 TYPE STANDARD TABLE OF SDCFC_00000731, WA_SDCFC_00000731 TYPE SDCFC_00000731, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <SDCFC_00000731> TYPE SDCFC_00000731. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_SDCFC_00000731. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM SDCFC_00000731 INTO TABLE IT_SDCFC_00000731. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM SDCFC_00000731 * INTO TABLE @DATA(IT_SDCFC_000007312). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_SDCFC_00000731 INDEX 1 INTO DATA(WA_SDCFC_000007312). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_SDCFC_00000731 ASSIGNING <SDCFC_00000731>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<SDCFC_00000731>-ADDIMATNR = 1.
<SDCFC_00000731>-ADDINUMBER = 1.
<SDCFC_00000731>-ADDIVKME = 1.
<SDCFC_00000731>-ADDIFM = 1.
<SDCFC_00000731>-ADDIFM_TXT = 1.
ENDLOOP. LOOP AT IT_SDCFC_00000731 INTO WA_SDCFC_00000731. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_SDCFC_00000731-ADDIKLART, sy-vline,
WA_SDCFC_00000731-ADDIKLART_TXT, sy-vline,
WA_SDCFC_00000731-ADDICLASS, sy-vline,
WA_SDCFC_00000731-ADDICLASS_TXT, sy-vline,
WA_SDCFC_00000731-ADDIIDOC, sy-vline,
WA_SDCFC_00000731-ADDIMATNR_EXTERNAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SDCFC_00000731 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SDCFC_00000731 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SDCFC_00000731 INTO WA_SDCFC_00000731. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SDCFC_00000731_STR,
ADDIMATNR TYPE STRING,
ADDINUMBER TYPE STRING,
ADDIVKME TYPE STRING,
ADDIFM TYPE STRING,
ADDIFM_TXT TYPE STRING,
ADDIKLART TYPE STRING,
ADDIKLART_TXT TYPE STRING,
ADDICLASS TYPE STRING,
ADDICLASS_TXT TYPE STRING,
ADDIIDOC TYPE STRING,
ADDIMATNR_EXTERNAL TYPE STRING,
ADDIMATNR_VERSION TYPE STRING,
ADDIMATNR_GUID TYPE STRING,
ADDIMATNR_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_SDCFC_00000731_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SDCFC_00000731_STR-ADDIMATNR sy-vline
WA_SDCFC_00000731_STR-ADDINUMBER sy-vline
WA_SDCFC_00000731_STR-ADDIVKME sy-vline
WA_SDCFC_00000731_STR-ADDIFM sy-vline
WA_SDCFC_00000731_STR-ADDIFM_TXT sy-vline
WA_SDCFC_00000731_STR-ADDIKLART sy-vline
WA_SDCFC_00000731_STR-ADDIKLART_TXT sy-vline
WA_SDCFC_00000731_STR-ADDICLASS sy-vline
WA_SDCFC_00000731_STR-ADDICLASS_TXT sy-vline
WA_SDCFC_00000731_STR-ADDIIDOC sy-vline
WA_SDCFC_00000731_STR-ADDIMATNR_EXTERNAL sy-vline
WA_SDCFC_00000731_STR-ADDIMATNR_VERSION sy-vline
WA_SDCFC_00000731_STR-ADDIMATNR_GUID sy-vline
WA_SDCFC_00000731_STR-ADDIMATNR_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.