ABAP Select data from SAP table SCPRRECORD_COMP_STRUCT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SCPRRECORD_COMP_STRUCT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SCPRRECORD_COMP_STRUCT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SCPRRECORD_COMP_STRUCT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SCPRRECORD_COMP_STRUCT TYPE STANDARD TABLE OF SCPRRECORD_COMP_STRUCT,
      WA_SCPRRECORD_COMP_STRUCT TYPE SCPRRECORD_COMP_STRUCT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SCPRRECORD_COMP_STRUCT> TYPE SCPRRECORD_COMP_STRUCT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SCPRRECORD_COMP_STRUCT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SCPRRECORD_COMP_STRUCT
  INTO TABLE IT_SCPRRECORD_COMP_STRUCT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SCPRRECORD_COMP_STRUCT
*  INTO TABLE @DATA(IT_SCPRRECORD_COMP_STRUCT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SCPRRECORD_COMP_STRUCT INDEX 1 INTO DATA(WA_SCPRRECORD_COMP_STRUCT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SCPRRECORD_COMP_STRUCT ASSIGNING <SCPRRECORD_COMP_STRUCT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SCPRRECORD_COMP_STRUCT>-ID = 1.
<SCPRRECORD_COMP_STRUCT>-CATEGORY = 1.
<SCPRRECORD_COMP_STRUCT>-TABLENAME = 1.
<SCPRRECORD_COMP_STRUCT>-TABLETYPE = 1.
<SCPRRECORD_COMP_STRUCT>-RECNUMBER = 1.
ENDLOOP.

LOOP AT IT_SCPRRECORD_COMP_STRUCT INTO WA_SCPRRECORD_COMP_STRUCT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SCPRRECORD_COMP_STRUCT-FLAG_TRESC, sy-vline,
WA_SCPRRECORD_COMP_STRUCT-DELETEFLAG, sy-vline,
WA_SCPRRECORD_COMP_STRUCT-UNCOMPLETE, sy-vline,
WA_SCPRRECORD_COMP_STRUCT-ALL_FIELDS, sy-vline,
WA_SCPRRECORD_COMP_STRUCT-BCSET_VALS, sy-vline,
WA_SCPRRECORD_COMP_STRUCT-BCSET_VALL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SCPRRECORD_COMP_STRUCT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SCPRRECORD_COMP_STRUCT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SCPRRECORD_COMP_STRUCT INTO WA_SCPRRECORD_COMP_STRUCT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SCPRRECORD_COMP_STRUCT_STR,
ID TYPE STRING,
CATEGORY TYPE STRING,
TABLENAME TYPE STRING,
TABLETYPE TYPE STRING,
RECNUMBER TYPE STRING,
FLAG_TRESC TYPE STRING,
DELETEFLAG TYPE STRING,
UNCOMPLETE TYPE STRING,
ALL_FIELDS TYPE STRING,
BCSET_VALS TYPE STRING,
BCSET_VALL TYPE STRING,
TABLE_VALS TYPE STRING,
TABLE_VALL TYPE STRING,
RECORD_DIFFERENCE TYPE STRING,
CHECKED TYPE STRING,END OF T_EKKO_STR. DATA: WA_SCPRRECORD_COMP_STRUCT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-ID sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-CATEGORY sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-TABLENAME sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-TABLETYPE sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-RECNUMBER sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-FLAG_TRESC sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-DELETEFLAG sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-UNCOMPLETE sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-ALL_FIELDS sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-BCSET_VALS sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-BCSET_VALL sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-TABLE_VALS sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-TABLE_VALL sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-RECORD_DIFFERENCE sy-vline
WA_SCPRRECORD_COMP_STRUCT_STR-CHECKED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.