ABAP Select data from SAP table SCOMPO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SCOMPO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SCOMPO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SCOMPO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SCOMPO TYPE STANDARD TABLE OF SCOMPO,
      WA_SCOMPO TYPE SCOMPO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SCOMPO> TYPE SCOMPO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SCOMPO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SCOMPO
  INTO TABLE IT_SCOMPO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SCOMPO
*  INTO TABLE @DATA(IT_SCOMPO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SCOMPO INDEX 1 INTO DATA(WA_SCOMPO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SCOMPO ASSIGNING <SCOMPO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SCOMPO>-TYPE = 1.
<SCOMPO>-NAME = 1.
<SCOMPO>-INCL = 1.
<SCOMPO>-CLASS = 1.
<SCOMPO>-EXPOSURE = 1.
ENDLOOP.

LOOP AT IT_SCOMPO INTO WA_SCOMPO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SCOMPO-INTERFACE, sy-vline,
WA_SCOMPO-IS_FINAL, sy-vline,
WA_SCOMPO-IS_ABSTRACT, sy-vline,
WA_SCOMPO-IS_FOR_TESTING, sy-vline,
WA_SCOMPO-IS_EVENT_HANDLER, sy-vline,
WA_SCOMPO-IS_CONSTRUCTOR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SCOMPO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SCOMPO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SCOMPO INTO WA_SCOMPO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SCOMPO_STR,
TYPE TYPE STRING,
NAME TYPE STRING,
INCL TYPE STRING,
CLASS TYPE STRING,
EXPOSURE TYPE STRING,
INTERFACE TYPE STRING,
IS_FINAL TYPE STRING,
IS_ABSTRACT TYPE STRING,
IS_FOR_TESTING TYPE STRING,
IS_EVENT_HANDLER TYPE STRING,
IS_CONSTRUCTOR TYPE STRING,
IS_REDEFINITION TYPE STRING,
IS_STATIC TYPE STRING,
IS_READ_ONLY TYPE STRING,
IS_CONSTANT TYPE STRING,
ROW TYPE STRING,
COL TYPE STRING,END OF T_EKKO_STR. DATA: WA_SCOMPO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SCOMPO_STR-TYPE sy-vline
WA_SCOMPO_STR-NAME sy-vline
WA_SCOMPO_STR-INCL sy-vline
WA_SCOMPO_STR-CLASS sy-vline
WA_SCOMPO_STR-EXPOSURE sy-vline
WA_SCOMPO_STR-INTERFACE sy-vline
WA_SCOMPO_STR-IS_FINAL sy-vline
WA_SCOMPO_STR-IS_ABSTRACT sy-vline
WA_SCOMPO_STR-IS_FOR_TESTING sy-vline
WA_SCOMPO_STR-IS_EVENT_HANDLER sy-vline
WA_SCOMPO_STR-IS_CONSTRUCTOR sy-vline
WA_SCOMPO_STR-IS_REDEFINITION sy-vline
WA_SCOMPO_STR-IS_STATIC sy-vline
WA_SCOMPO_STR-IS_READ_ONLY sy-vline
WA_SCOMPO_STR-IS_CONSTANT sy-vline
WA_SCOMPO_STR-ROW sy-vline
WA_SCOMPO_STR-COL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.