ABAP Select data from SAP table SCMC_SYSTEMS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SCMC_SYSTEMS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SCMC_SYSTEMS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SCMC_SYSTEMS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SCMC_SYSTEMS TYPE STANDARD TABLE OF SCMC_SYSTEMS,
      WA_SCMC_SYSTEMS TYPE SCMC_SYSTEMS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SCMC_SYSTEMS> TYPE SCMC_SYSTEMS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SCMC_SYSTEMS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SCMC_SYSTEMS
  INTO TABLE IT_SCMC_SYSTEMS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SCMC_SYSTEMS
*  INTO TABLE @DATA(IT_SCMC_SYSTEMS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SCMC_SYSTEMS INDEX 1 INTO DATA(WA_SCMC_SYSTEMS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SCMC_SYSTEMS ASSIGNING <SCMC_SYSTEMS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SCMC_SYSTEMS>-GUID = 1.
<SCMC_SYSTEMS>-SYSTEMALIAS = 1.
<SCMC_SYSTEMS>-SYSTEMNAME = 1.
<SCMC_SYSTEMS>-DBTYPE = 1.
<SCMC_SYSTEMS>-MONITORNAME = 1.
ENDLOOP.

LOOP AT IT_SCMC_SYSTEMS INTO WA_SCMC_SYSTEMS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SCMC_SYSTEMS-CAPTION, sy-vline,
WA_SCMC_SYSTEMS-MSGSERVER, sy-vline,
WA_SCMC_SYSTEMS-CAPPSERVER, sy-vline,
WA_SCMC_SYSTEMS-SYSNO, sy-vline,
WA_SCMC_SYSTEMS-RFCDEST, sy-vline,
WA_SCMC_SYSTEMS-INSTANCENAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SCMC_SYSTEMS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SCMC_SYSTEMS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SCMC_SYSTEMS INTO WA_SCMC_SYSTEMS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SCMC_SYSTEMS_STR,
GUID TYPE STRING,
SYSTEMALIAS TYPE STRING,
SYSTEMNAME TYPE STRING,
DBTYPE TYPE STRING,
MONITORNAME TYPE STRING,
CAPTION TYPE STRING,
MSGSERVER TYPE STRING,
CAPPSERVER TYPE STRING,
SYSNO TYPE STRING,
RFCDEST TYPE STRING,
INSTANCENAME TYPE STRING,
GENTIMESTAMP TYPE STRING,
GENUSER TYPE STRING,
VERSION TYPE STRING,END OF T_EKKO_STR. DATA: WA_SCMC_SYSTEMS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SCMC_SYSTEMS_STR-GUID sy-vline
WA_SCMC_SYSTEMS_STR-SYSTEMALIAS sy-vline
WA_SCMC_SYSTEMS_STR-SYSTEMNAME sy-vline
WA_SCMC_SYSTEMS_STR-DBTYPE sy-vline
WA_SCMC_SYSTEMS_STR-MONITORNAME sy-vline
WA_SCMC_SYSTEMS_STR-CAPTION sy-vline
WA_SCMC_SYSTEMS_STR-MSGSERVER sy-vline
WA_SCMC_SYSTEMS_STR-CAPPSERVER sy-vline
WA_SCMC_SYSTEMS_STR-SYSNO sy-vline
WA_SCMC_SYSTEMS_STR-RFCDEST sy-vline
WA_SCMC_SYSTEMS_STR-INSTANCENAME sy-vline
WA_SCMC_SYSTEMS_STR-GENTIMESTAMP sy-vline
WA_SCMC_SYSTEMS_STR-GENUSER sy-vline
WA_SCMC_SYSTEMS_STR-VERSION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.