ABAP Select data from SAP table SCIREST_PS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SCIREST_PS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SCIREST_PS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SCIREST_PS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SCIREST_PS TYPE STANDARD TABLE OF SCIREST_PS,
      WA_SCIREST_PS TYPE SCIREST_PS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SCIREST_PS> TYPE SCIREST_PS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SCIREST_PS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SCIREST_PS
  INTO TABLE IT_SCIREST_PS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SCIREST_PS
*  INTO TABLE @DATA(IT_SCIREST_PS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SCIREST_PS INDEX 1 INTO DATA(WA_SCIREST_PS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SCIREST_PS ASSIGNING <SCIREST_PS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SCIREST_PS>-INSPECID = 1.
<SCIREST_PS>-INSPECVERS = 1.
<SCIREST_PS>-CIUSER = 1.
<SCIREST_PS>-OBJTYPE = 1.
<SCIREST_PS>-OBJNAME = 1.
ENDLOOP.

LOOP AT IT_SCIREST_PS INTO WA_SCIREST_PS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SCIREST_PS-TEST, sy-vline,
WA_SCIREST_PS-ERRCNT, sy-vline,
WA_SCIREST_PS-CONSECCNT, sy-vline,
WA_SCIREST_PS-SOBJNAME, sy-vline,
WA_SCIREST_PS-SOBJTYPE, sy-vline,
WA_SCIREST_PS-LINE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SCIREST_PS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SCIREST_PS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SCIREST_PS INTO WA_SCIREST_PS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SCIREST_PS_STR,
INSPECID TYPE STRING,
INSPECVERS TYPE STRING,
CIUSER TYPE STRING,
OBJTYPE TYPE STRING,
OBJNAME TYPE STRING,
TEST TYPE STRING,
ERRCNT TYPE STRING,
CONSECCNT TYPE STRING,
SOBJNAME TYPE STRING,
SOBJTYPE TYPE STRING,
LINE TYPE STRING,
COL TYPE STRING,
KIND TYPE STRING,
CODE TYPE STRING,
PROGRAM_NAME TYPE STRING,
PARAM1 TYPE STRING,
PARAM2 TYPE STRING,
PARAM3 TYPE STRING,
PARAM4 TYPE STRING,
CHECKSUM1 TYPE STRING,
EXCEPTN TYPE STRING,
INCLSPEC TYPE STRING,
DETAIL TYPE STRING,END OF T_EKKO_STR. DATA: WA_SCIREST_PS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SCIREST_PS_STR-INSPECID sy-vline
WA_SCIREST_PS_STR-INSPECVERS sy-vline
WA_SCIREST_PS_STR-CIUSER sy-vline
WA_SCIREST_PS_STR-OBJTYPE sy-vline
WA_SCIREST_PS_STR-OBJNAME sy-vline
WA_SCIREST_PS_STR-TEST sy-vline
WA_SCIREST_PS_STR-ERRCNT sy-vline
WA_SCIREST_PS_STR-CONSECCNT sy-vline
WA_SCIREST_PS_STR-SOBJNAME sy-vline
WA_SCIREST_PS_STR-SOBJTYPE sy-vline
WA_SCIREST_PS_STR-LINE sy-vline
WA_SCIREST_PS_STR-COL sy-vline
WA_SCIREST_PS_STR-KIND sy-vline
WA_SCIREST_PS_STR-CODE sy-vline
WA_SCIREST_PS_STR-PROGRAM_NAME sy-vline
WA_SCIREST_PS_STR-PARAM1 sy-vline
WA_SCIREST_PS_STR-PARAM2 sy-vline
WA_SCIREST_PS_STR-PARAM3 sy-vline
WA_SCIREST_PS_STR-PARAM4 sy-vline
WA_SCIREST_PS_STR-CHECKSUM1 sy-vline
WA_SCIREST_PS_STR-EXCEPTN sy-vline
WA_SCIREST_PS_STR-INCLSPEC sy-vline
WA_SCIREST_PS_STR-DETAIL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.