ABAP Select data from SAP table S950E into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP S950E table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to S950E. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the S950E table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_S950E TYPE STANDARD TABLE OF S950E,
      WA_S950E TYPE S950E,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <S950E> TYPE S950E.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_S950E.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM S950E
  INTO TABLE IT_S950E.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM S950E
*  INTO TABLE @DATA(IT_S950E2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_S950E INDEX 1 INTO DATA(WA_S950E2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_S950E ASSIGNING <S950E>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<S950E>-MANDT = 1.
<S950E>-SSOUR = 1.
<S950E>-TPLST = 1.
<S950E>-TDLNR = 1.
<S950E>-TKNUM = 1.
ENDLOOP.

LOOP AT IT_S950E INTO WA_S950E.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_S950E-GTART, sy-vline,
WA_S950E-MATNR, sy-vline,
WA_S950E-VSTELA, sy-vline,
WA_S950E-AZONE, sy-vline,
WA_S950E-PSTLZZ, sy-vline,
WA_S950E-LZONE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_S950E you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_S950E TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_S950E INTO WA_S950E. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field TDLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_S950E-TDLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S950E-TDLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TKNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_S950E-TKNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S950E-TKNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_S950E-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S950E-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field STAGEW CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_S950E-STAGEW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S950E-STAGEW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field STAVOL CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_S950E-STAVOL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S950E-STAVOL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_S950E-BASME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S950E-BASME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEDST CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_S950E-MEDST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S950E-MEDST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_S950E_STR,
MANDT TYPE STRING,
SSOUR TYPE STRING,
TPLST TYPE STRING,
TDLNR TYPE STRING,
TKNUM TYPE STRING,
GTART TYPE STRING,
MATNR TYPE STRING,
VSTELA TYPE STRING,
AZONE TYPE STRING,
PSTLZZ TYPE STRING,
LZONE TYPE STRING,
STAGEW TYPE STRING,
STAVOL TYPE STRING,
BASME TYPE STRING,
MEDST TYPE STRING,
USTAGEW TYPE STRING,
USTAVOL TYPE STRING,
UBASME TYPE STRING,
UMEDST TYPE STRING,
PLOBJ TYPE STRING,
PERKZ TYPE STRING,
PERIV TYPE STRING,
PLTKZ TYPE STRING,
ANTEI TYPE STRING,END OF T_EKKO_STR. DATA: WA_S950E_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_S950E_STR-MANDT sy-vline
WA_S950E_STR-SSOUR sy-vline
WA_S950E_STR-TPLST sy-vline
WA_S950E_STR-TDLNR sy-vline
WA_S950E_STR-TKNUM sy-vline
WA_S950E_STR-GTART sy-vline
WA_S950E_STR-MATNR sy-vline
WA_S950E_STR-VSTELA sy-vline
WA_S950E_STR-AZONE sy-vline
WA_S950E_STR-PSTLZZ sy-vline
WA_S950E_STR-LZONE sy-vline
WA_S950E_STR-STAGEW sy-vline
WA_S950E_STR-STAVOL sy-vline
WA_S950E_STR-BASME sy-vline
WA_S950E_STR-MEDST sy-vline
WA_S950E_STR-USTAGEW sy-vline
WA_S950E_STR-USTAVOL sy-vline
WA_S950E_STR-UBASME sy-vline
WA_S950E_STR-UMEDST sy-vline
WA_S950E_STR-PLOBJ sy-vline
WA_S950E_STR-PERKZ sy-vline
WA_S950E_STR-PERIV sy-vline
WA_S950E_STR-PLTKZ sy-vline
WA_S950E_STR-ANTEI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.