ABAP Select data from SAP table S944 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP S944 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to S944. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the S944 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_S944 TYPE STANDARD TABLE OF S944,
      WA_S944 TYPE S944,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <S944> TYPE S944.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_S944.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM S944
  INTO TABLE IT_S944.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM S944
*  INTO TABLE @DATA(IT_S9442).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_S944 INDEX 1 INTO DATA(WA_S9442).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_S944 ASSIGNING <S944>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<S944>-MANDT = 1.
<S944>-SSOUR = 1.
<S944>-VRSIO = 1.
<S944>-SPMON = 1.
<S944>-SPTAG = 1.
ENDLOOP.

LOOP AT IT_S944 INTO WA_S944.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_S944-SPWOC, sy-vline,
WA_S944-SPBUP, sy-vline,
WA_S944-EKORG, sy-vline,
WA_S944-WERKS, sy-vline,
WA_S944-LIFNR, sy-vline,
WA_S944-MATKL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_S944 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_S944 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_S944 INTO WA_S944. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PERI, internal->external for field SPMON CALL FUNCTION 'CONVERSION_EXIT_PERI_OUTPUT' EXPORTING input = WA_S944-SPMON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S944-SPMON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI, internal->external for field SPWOC CALL FUNCTION 'CONVERSION_EXIT_PERI_OUTPUT' EXPORTING input = WA_S944-SPWOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S944-SPWOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI, internal->external for field SPBUP CALL FUNCTION 'CONVERSION_EXIT_PERI_OUTPUT' EXPORTING input = WA_S944-SPBUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S944-SPBUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_S944-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S944-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_S944-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S944-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_S944-BASME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S944-BASME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_S944_STR,
MANDT TYPE STRING,
SSOUR TYPE STRING,
VRSIO TYPE STRING,
SPMON TYPE STRING,
SPTAG TYPE STRING,
SPWOC TYPE STRING,
SPBUP TYPE STRING,
EKORG TYPE STRING,
WERKS TYPE STRING,
LIFNR TYPE STRING,
MATKL TYPE STRING,
MATNR TYPE STRING,
PERIV TYPE STRING,
VWDAT TYPE STRING,
BASME TYPE STRING,
HWAER TYPE STRING,
MENGE TYPE STRING,
WEMNG TYPE STRING,
REMNG TYPE STRING,
LSMNG TYPE STRING,
NETWR TYPE STRING,
REWRT TYPE STRING,
ABSTP TYPE STRING,END OF T_EKKO_STR. DATA: WA_S944_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_S944_STR-MANDT sy-vline
WA_S944_STR-SSOUR sy-vline
WA_S944_STR-VRSIO sy-vline
WA_S944_STR-SPMON sy-vline
WA_S944_STR-SPTAG sy-vline
WA_S944_STR-SPWOC sy-vline
WA_S944_STR-SPBUP sy-vline
WA_S944_STR-EKORG sy-vline
WA_S944_STR-WERKS sy-vline
WA_S944_STR-LIFNR sy-vline
WA_S944_STR-MATKL sy-vline
WA_S944_STR-MATNR sy-vline
WA_S944_STR-PERIV sy-vline
WA_S944_STR-VWDAT sy-vline
WA_S944_STR-BASME sy-vline
WA_S944_STR-HWAER sy-vline
WA_S944_STR-MENGE sy-vline
WA_S944_STR-WEMNG sy-vline
WA_S944_STR-REMNG sy-vline
WA_S944_STR-LSMNG sy-vline
WA_S944_STR-NETWR sy-vline
WA_S944_STR-REWRT sy-vline
WA_S944_STR-ABSTP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.