ABAP Select data from SAP table S455 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP S455 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to S455. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the S455 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_S455 TYPE STANDARD TABLE OF S455,
      WA_S455 TYPE S455,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <S455> TYPE S455.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_S455.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM S455
  INTO TABLE IT_S455.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM S455
*  INTO TABLE @DATA(IT_S4552).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_S455 INDEX 1 INTO DATA(WA_S4552).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_S455 ASSIGNING <S455>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<S455>-MANDT = 1.
<S455>-SSOUR = 1.
<S455>-VRSIO = 1.
<S455>-SPMON = 1.
<S455>-SPTAG = 1.
ENDLOOP.

LOOP AT IT_S455 INTO WA_S455.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_S455-SPWOC, sy-vline,
WA_S455-SPBUP, sy-vline,
WA_S455-BEZUGGRD, sy-vline,
WA_S455-WERBEART, sy-vline,
WA_S455-WERBEAKT, sy-vline,
WA_S455-VKORG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_S455 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_S455 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_S455 INTO WA_S455. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PERI, internal->external for field SPMON CALL FUNCTION 'CONVERSION_EXIT_PERI_OUTPUT' EXPORTING input = WA_S455-SPMON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S455-SPMON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI, internal->external for field SPWOC CALL FUNCTION 'CONVERSION_EXIT_PERI_OUTPUT' EXPORTING input = WA_S455-SPWOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S455-SPWOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI, internal->external for field SPBUP CALL FUNCTION 'CONVERSION_EXIT_PERI_OUTPUT' EXPORTING input = WA_S455-SPBUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S455-SPBUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WERBEART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_S455-WERBEART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S455-WERBEART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WERBEAKT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_S455-WERBEAKT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S455-WERBEAKT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DRERZ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_S455-DRERZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S455-DRERZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PVA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_S455-PVA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S455-PVA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ETMEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_S455-ETMEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S455-ETMEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_S455_STR,
MANDT TYPE STRING,
SSOUR TYPE STRING,
VRSIO TYPE STRING,
SPMON TYPE STRING,
SPTAG TYPE STRING,
SPWOC TYPE STRING,
SPBUP TYPE STRING,
BEZUGGRD TYPE STRING,
WERBEART TYPE STRING,
WERBEAKT TYPE STRING,
VKORG TYPE STRING,
DRERZ TYPE STRING,
PVA TYPE STRING,
PERIV TYPE STRING,
VWDAT TYPE STRING,
ETMEINS TYPE STRING,
STWAE TYPE STRING,
LFMNGAU TYPE STRING,
REMMENGE TYPE STRING,
ANZREM TYPE STRING,
ANZREMPOS TYPE STRING,
REKMENGE TYPE STRING,
NLMENGE TYPE STRING,
BEZMENGE TYPE STRING,
ANZREK TYPE STRING,
ANZREKPOS TYPE STRING,
UMNETWR TYPE STRING,
UMBRTWR TYPE STRING,
GUNETWR TYPE STRING,
GUBRTWR TYPE STRING,
UMKZWI1 TYPE STRING,
UMKZWI2 TYPE STRING,
UMKZWI3 TYPE STRING,
UMKZWI4 TYPE STRING,
UMKZWI5 TYPE STRING,
UMKZWI6 TYPE STRING,
GUKZWI1 TYPE STRING,
GUKZWI2 TYPE STRING,
GUKZWI3 TYPE STRING,
GUKZWI4 TYPE STRING,
GUKZWI5 TYPE STRING,
GUKZWI6 TYPE STRING,END OF T_EKKO_STR. DATA: WA_S455_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_S455_STR-MANDT sy-vline
WA_S455_STR-SSOUR sy-vline
WA_S455_STR-VRSIO sy-vline
WA_S455_STR-SPMON sy-vline
WA_S455_STR-SPTAG sy-vline
WA_S455_STR-SPWOC sy-vline
WA_S455_STR-SPBUP sy-vline
WA_S455_STR-BEZUGGRD sy-vline
WA_S455_STR-WERBEART sy-vline
WA_S455_STR-WERBEAKT sy-vline
WA_S455_STR-VKORG sy-vline
WA_S455_STR-DRERZ sy-vline
WA_S455_STR-PVA sy-vline
WA_S455_STR-PERIV sy-vline
WA_S455_STR-VWDAT sy-vline
WA_S455_STR-ETMEINS sy-vline
WA_S455_STR-STWAE sy-vline
WA_S455_STR-LFMNGAU sy-vline
WA_S455_STR-REMMENGE sy-vline
WA_S455_STR-ANZREM sy-vline
WA_S455_STR-ANZREMPOS sy-vline
WA_S455_STR-REKMENGE sy-vline
WA_S455_STR-NLMENGE sy-vline
WA_S455_STR-BEZMENGE sy-vline
WA_S455_STR-ANZREK sy-vline
WA_S455_STR-ANZREKPOS sy-vline
WA_S455_STR-UMNETWR sy-vline
WA_S455_STR-UMBRTWR sy-vline
WA_S455_STR-GUNETWR sy-vline
WA_S455_STR-GUBRTWR sy-vline
WA_S455_STR-UMKZWI1 sy-vline
WA_S455_STR-UMKZWI2 sy-vline
WA_S455_STR-UMKZWI3 sy-vline
WA_S455_STR-UMKZWI4 sy-vline
WA_S455_STR-UMKZWI5 sy-vline
WA_S455_STR-UMKZWI6 sy-vline
WA_S455_STR-GUKZWI1 sy-vline
WA_S455_STR-GUKZWI2 sy-vline
WA_S455_STR-GUKZWI3 sy-vline
WA_S455_STR-GUKZWI4 sy-vline
WA_S455_STR-GUKZWI5 sy-vline
WA_S455_STR-GUKZWI6 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.