ABAP Select data from SAP table S197E into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP S197E table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to S197E. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the S197E table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_S197E TYPE STANDARD TABLE OF S197E,
      WA_S197E TYPE S197E,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <S197E> TYPE S197E.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_S197E.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM S197E
  INTO TABLE IT_S197E.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM S197E
*  INTO TABLE @DATA(IT_S197E2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_S197E INDEX 1 INTO DATA(WA_S197E2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_S197E ASSIGNING <S197E>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<S197E>-MANDT = 1.
<S197E>-SSOUR = 1.
<S197E>-MATNR = 1.
<S197E>-WERKS = 1.
<S197E>-LGORT = 1.
ENDLOOP.

LOOP AT IT_S197E INTO WA_S197E.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_S197E-BASME, sy-vline,
WA_S197E-UBASME, sy-vline,
WA_S197E-PLOBJ, sy-vline,
WA_S197E-PERKZ, sy-vline,
WA_S197E-PERIV, sy-vline,
WA_S197E-PLTKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_S197E you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_S197E TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_S197E INTO WA_S197E. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_S197E-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S197E-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_S197E-BASME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S197E-BASME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_S197E_STR,
MANDT TYPE STRING,
SSOUR TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
BASME TYPE STRING,
UBASME TYPE STRING,
PLOBJ TYPE STRING,
PERKZ TYPE STRING,
PERIV TYPE STRING,
PLTKZ TYPE STRING,
ANTEI TYPE STRING,END OF T_EKKO_STR. DATA: WA_S197E_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_S197E_STR-MANDT sy-vline
WA_S197E_STR-SSOUR sy-vline
WA_S197E_STR-MATNR sy-vline
WA_S197E_STR-WERKS sy-vline
WA_S197E_STR-LGORT sy-vline
WA_S197E_STR-BASME sy-vline
WA_S197E_STR-UBASME sy-vline
WA_S197E_STR-PLOBJ sy-vline
WA_S197E_STR-PERKZ sy-vline
WA_S197E_STR-PERIV sy-vline
WA_S197E_STR-PLTKZ sy-vline
WA_S197E_STR-ANTEI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.