ABAP Select data from SAP table RPUBEN46_ALV1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPUBEN46_ALV1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPUBEN46_ALV1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RPUBEN46_ALV1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RPUBEN46_ALV1 TYPE STANDARD TABLE OF RPUBEN46_ALV1,
      WA_RPUBEN46_ALV1 TYPE RPUBEN46_ALV1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RPUBEN46_ALV1> TYPE RPUBEN46_ALV1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RPUBEN46_ALV1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RPUBEN46_ALV1
  INTO TABLE IT_RPUBEN46_ALV1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RPUBEN46_ALV1
*  INTO TABLE @DATA(IT_RPUBEN46_ALV12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RPUBEN46_ALV1 INDEX 1 INTO DATA(WA_RPUBEN46_ALV12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RPUBEN46_ALV1 ASSIGNING <RPUBEN46_ALV1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPUBEN46_ALV1>-BPLAN = 1.
<RPUBEN46_ALV1>-PSDAT = 1.
<RPUBEN46_ALV1>-BOPTI = 1.
<RPUBEN46_ALV1>-DEPCV = 1.
<RPUBEN46_ALV1>-BCOST = 1.
ENDLOOP.

LOOP AT IT_RPUBEN46_ALV1 INTO WA_RPUBEN46_ALV1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RPUBEN46_ALV1-PERIO, sy-vline,
WA_RPUBEN46_ALV1-EECST, sy-vline,
WA_RPUBEN46_ALV1-PTCST, sy-vline,
WA_RPUBEN46_ALV1-ERCST, sy-vline,
WA_RPUBEN46_ALV1-ACCST, sy-vline,
WA_RPUBEN46_ALV1-IMINC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPUBEN46_ALV1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPUBEN46_ALV1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPUBEN46_ALV1 INTO WA_RPUBEN46_ALV1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPUBEN46_ALV1_STR,
BPLAN TYPE STRING,
PSDAT TYPE STRING,
BOPTI TYPE STRING,
DEPCV TYPE STRING,
BCOST TYPE STRING,
PERIO TYPE STRING,
EECST TYPE STRING,
PTCST TYPE STRING,
ERCST TYPE STRING,
ACCST TYPE STRING,
IMINC TYPE STRING,
CURRE TYPE STRING,
SALGR TYPE STRING,
AGEGR TYPE STRING,
LOSGR TYPE STRING,
CSTV1 TYPE STRING,
GENDR TYPE STRING,
SMOKE TYPE STRING,
LIMIT TYPE STRING,
CSDAT TYPE STRING,
CEDAT TYPE STRING,
BCOVR TYPE STRING,
INCRE TYPE STRING,
CSTFA TYPE STRING,
ERCFA TYPE STRING,
ACCFA TYPE STRING,
LEVL1 TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPUBEN46_ALV1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPUBEN46_ALV1_STR-BPLAN sy-vline
WA_RPUBEN46_ALV1_STR-PSDAT sy-vline
WA_RPUBEN46_ALV1_STR-BOPTI sy-vline
WA_RPUBEN46_ALV1_STR-DEPCV sy-vline
WA_RPUBEN46_ALV1_STR-BCOST sy-vline
WA_RPUBEN46_ALV1_STR-PERIO sy-vline
WA_RPUBEN46_ALV1_STR-EECST sy-vline
WA_RPUBEN46_ALV1_STR-PTCST sy-vline
WA_RPUBEN46_ALV1_STR-ERCST sy-vline
WA_RPUBEN46_ALV1_STR-ACCST sy-vline
WA_RPUBEN46_ALV1_STR-IMINC sy-vline
WA_RPUBEN46_ALV1_STR-CURRE sy-vline
WA_RPUBEN46_ALV1_STR-SALGR sy-vline
WA_RPUBEN46_ALV1_STR-AGEGR sy-vline
WA_RPUBEN46_ALV1_STR-LOSGR sy-vline
WA_RPUBEN46_ALV1_STR-CSTV1 sy-vline
WA_RPUBEN46_ALV1_STR-GENDR sy-vline
WA_RPUBEN46_ALV1_STR-SMOKE sy-vline
WA_RPUBEN46_ALV1_STR-LIMIT sy-vline
WA_RPUBEN46_ALV1_STR-CSDAT sy-vline
WA_RPUBEN46_ALV1_STR-CEDAT sy-vline
WA_RPUBEN46_ALV1_STR-BCOVR sy-vline
WA_RPUBEN46_ALV1_STR-INCRE sy-vline
WA_RPUBEN46_ALV1_STR-CSTFA sy-vline
WA_RPUBEN46_ALV1_STR-ERCFA sy-vline
WA_RPUBEN46_ALV1_STR-ACCFA sy-vline
WA_RPUBEN46_ALV1_STR-LEVL1 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.