ABAP Select data from SAP table RPM_TS_PROJECT_BPS_SYSTEM_INFO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPM_TS_PROJECT_BPS_SYSTEM_INFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPM_TS_PROJECT_BPS_SYSTEM_INFO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RPM_TS_PROJECT_BPS_SYSTEM_INFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RPM_TS_PROJECT_BPS_SYSTEM_INFO TYPE STANDARD TABLE OF RPM_TS_PROJECT_BPS_SYSTEM_INFO,
      WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO TYPE RPM_TS_PROJECT_BPS_SYSTEM_INFO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RPM_TS_PROJECT_BPS_SYSTEM_INFO> TYPE RPM_TS_PROJECT_BPS_SYSTEM_INFO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RPM_TS_PROJECT_BPS_SYSTEM_INFO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RPM_TS_PROJECT_BPS_SYSTEM_INFO
  INTO TABLE IT_RPM_TS_PROJECT_BPS_SYSTEM_INFO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RPM_TS_PROJECT_BPS_SYSTEM_INFO
*  INTO TABLE @DATA(IT_RPM_TS_PROJECT_BPS_SYSTEM_INFO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RPM_TS_PROJECT_BPS_SYSTEM_INFO INDEX 1 INTO DATA(WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RPM_TS_PROJECT_BPS_SYSTEM_INFO ASSIGNING <RPM_TS_PROJECT_BPS_SYSTEM_INFO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPM_TS_PROJECT_BPS_SYSTEM_INFO>-APPLICATION = 1.
<RPM_TS_PROJECT_BPS_SYSTEM_INFO>-OBJECT_TYPE = 1.
<RPM_TS_PROJECT_BPS_SYSTEM_INFO>-LOGSYS = 1.
<RPM_TS_PROJECT_BPS_SYSTEM_INFO>-STEXT = 1.
<RPM_TS_PROJECT_BPS_SYSTEM_INFO>-RFC_DESTINATION = 1.
ENDLOOP.

LOOP AT IT_RPM_TS_PROJECT_BPS_SYSTEM_INFO INTO WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-OBJECT_KEY, sy-vline,
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-SERVICENR, sy-vline,
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-SERVER, sy-vline,
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-PATH_PREFIX, sy-vline,
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-SYSTEMNR, sy-vline,
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-GROUP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPM_TS_PROJECT_BPS_SYSTEM_INFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPM_TS_PROJECT_BPS_SYSTEM_INFO INTO WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGUAGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-LANGUAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-LANGUAGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field PSPID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-PSPID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO-PSPID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR,
APPLICATION TYPE STRING,
OBJECT_TYPE TYPE STRING,
LOGSYS TYPE STRING,
STEXT TYPE STRING,
RFC_DESTINATION TYPE STRING,
OBJECT_KEY TYPE STRING,
SERVICENR TYPE STRING,
SERVER TYPE STRING,
PATH_PREFIX TYPE STRING,
SYSTEMNR TYPE STRING,
GROUP TYPE STRING,
LANGUAGE TYPE STRING,
CLIENT TYPE STRING,
USER TYPE STRING,
PSPID TYPE STRING,
PTEXT TYPE STRING,
WEB_SERVER TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-APPLICATION sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-OBJECT_TYPE sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-LOGSYS sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-STEXT sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-RFC_DESTINATION sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-OBJECT_KEY sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-SERVICENR sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-SERVER sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-PATH_PREFIX sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-SYSTEMNR sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-GROUP sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-LANGUAGE sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-CLIENT sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-USER sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-PSPID sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-PTEXT sy-vline
WA_RPM_TS_PROJECT_BPS_SYSTEM_INFO_STR-WEB_SERVER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.